File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/j.echo.2019.07.002
- Scopus: eid_2-s2.0-85072510724
- PMID: 31563435
- WOS: WOS:000500357700005
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Prognostic value of Tricuspid valve geometry and leaflet coaptation status in patients undergoing Tricuspid Annuloplasty: A three-dimensional echocardiography study
Title | Prognostic value of Tricuspid valve geometry and leaflet coaptation status in patients undergoing Tricuspid Annuloplasty: A three-dimensional echocardiography study |
---|---|
Authors | |
Keywords | Tricuspid regurgitation Tricuspid annuloplasty Tricuspid valve geometry Three-dimensional echocardiography |
Issue Date | 2019 |
Publisher | Mosby, Inc. The Journal's web site is located at http://www.elsevier.com/locate/echo |
Citation | Journal of The American Society of Echocardiography, 2019, v. 32 n. 12, p. 1516-1525 How to Cite? |
Abstract | Background:
The advent of three-dimensional echocardiography (3DE) enables detailed evaluation of the tricuspid valve (TV) apparatus; nonetheless, the clinical value of preoperative 3DE is unknown in patients undergoing tricuspid annuloplasty (TA). The aim of this study was to evaluate the prognostic value of TV geometric parameters and leaflet coaptation status evaluated by 3DE in patients undergoing TA.
Methods:
A total of 122 patients who underwent TA during left-sided heart valve surgery were prospectively evaluated. Detailed 3DE was performed before surgery. Adverse outcome was defined as the occurrence of heart failure requiring hospital admission or all-cause mortality following TA.
Results:
A total of 33 adverse events (17 heart failures and 16 deaths) occurred during a median follow-up of 36 months. Tethering volume (hazard ratio = 1.32; 95% CI = 1.05-1.66; P = .01) and ratio of total leaflet length to closure length (hazard ratio = 1.07; 95% CI = 1.03-1.12; P < .01) were associated with adverse events after adjustment for age, sex, and tricuspid regurgitation vena contracta width. Receiver-operator characteristic curve analysis revealed that tethering volume (area under curve = 0.73) and ratio of total leaflet length to closure length (area under curve = 0.75) were most associated with adverse events at 1-year follow-up. The presence of either a large tethering volume or a low ratio of total leaflet length to closure length was predictive of an adverse outcome 1 year following TA.
Conclusions:
Our study suggests that 3DE-derived TV tethering volume and ratio of total leaflet length to closure length are important preoperative measures associated with adverse events in patients undergoing TA. |
Persistent Identifier | http://hdl.handle.net/10722/283228 |
ISSN | 2023 Impact Factor: 5.4 2023 SCImago Journal Rankings: 2.041 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chen, Y | - |
dc.contributor.author | Liu, YX | - |
dc.contributor.author | Yu, YJ | - |
dc.contributor.author | Wu, MZ | - |
dc.contributor.author | Lam, YM | - |
dc.contributor.author | Sit, KY | - |
dc.contributor.author | Chan, DTL | - |
dc.contributor.author | Ho, CKL | - |
dc.contributor.author | Ho, LM | - |
dc.contributor.author | Fang, LG | - |
dc.contributor.author | Zhang, SY | - |
dc.contributor.author | Lau, CP | - |
dc.contributor.author | Au, WK | - |
dc.contributor.author | Tse, HF | - |
dc.contributor.author | Yiu, KH | - |
dc.date.accessioned | 2020-06-22T02:53:44Z | - |
dc.date.available | 2020-06-22T02:53:44Z | - |
dc.date.issued | 2019 | - |
dc.identifier.citation | Journal of The American Society of Echocardiography, 2019, v. 32 n. 12, p. 1516-1525 | - |
dc.identifier.issn | 0894-7317 | - |
dc.identifier.uri | http://hdl.handle.net/10722/283228 | - |
dc.description.abstract | Background: The advent of three-dimensional echocardiography (3DE) enables detailed evaluation of the tricuspid valve (TV) apparatus; nonetheless, the clinical value of preoperative 3DE is unknown in patients undergoing tricuspid annuloplasty (TA). The aim of this study was to evaluate the prognostic value of TV geometric parameters and leaflet coaptation status evaluated by 3DE in patients undergoing TA. Methods: A total of 122 patients who underwent TA during left-sided heart valve surgery were prospectively evaluated. Detailed 3DE was performed before surgery. Adverse outcome was defined as the occurrence of heart failure requiring hospital admission or all-cause mortality following TA. Results: A total of 33 adverse events (17 heart failures and 16 deaths) occurred during a median follow-up of 36 months. Tethering volume (hazard ratio = 1.32; 95% CI = 1.05-1.66; P = .01) and ratio of total leaflet length to closure length (hazard ratio = 1.07; 95% CI = 1.03-1.12; P < .01) were associated with adverse events after adjustment for age, sex, and tricuspid regurgitation vena contracta width. Receiver-operator characteristic curve analysis revealed that tethering volume (area under curve = 0.73) and ratio of total leaflet length to closure length (area under curve = 0.75) were most associated with adverse events at 1-year follow-up. The presence of either a large tethering volume or a low ratio of total leaflet length to closure length was predictive of an adverse outcome 1 year following TA. Conclusions: Our study suggests that 3DE-derived TV tethering volume and ratio of total leaflet length to closure length are important preoperative measures associated with adverse events in patients undergoing TA. | - |
dc.language | eng | - |
dc.publisher | Mosby, Inc. The Journal's web site is located at http://www.elsevier.com/locate/echo | - |
dc.relation.ispartof | Journal of The American Society of Echocardiography | - |
dc.subject | Tricuspid regurgitation | - |
dc.subject | Tricuspid annuloplasty | - |
dc.subject | Tricuspid valve geometry | - |
dc.subject | Three-dimensional echocardiography | - |
dc.title | Prognostic value of Tricuspid valve geometry and leaflet coaptation status in patients undergoing Tricuspid Annuloplasty: A three-dimensional echocardiography study | - |
dc.type | Article | - |
dc.identifier.email | Lam, YM: lamym2@hku.hk | - |
dc.identifier.email | Ho, LM: lmho@hku.hk | - |
dc.identifier.email | Lau, CP: cplau@hkucc.hku.hk | - |
dc.identifier.email | Au, WK: auwkt@hkucc.hku.hk | - |
dc.identifier.email | Tse, HF: hftse@hkucc.hku.hk | - |
dc.identifier.email | Yiu, KH: khkyiu@hku.hk | - |
dc.identifier.authority | Ho, LM=rp00360 | - |
dc.identifier.authority | Tse, HF=rp00428 | - |
dc.identifier.authority | Yiu, KH=rp01490 | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/j.echo.2019.07.002 | - |
dc.identifier.pmid | 31563435 | - |
dc.identifier.scopus | eid_2-s2.0-85072510724 | - |
dc.identifier.hkuros | 310486 | - |
dc.identifier.volume | 32 | - |
dc.identifier.issue | 12 | - |
dc.identifier.spage | 1516 | - |
dc.identifier.epage | 1525 | - |
dc.identifier.isi | WOS:000500357700005 | - |
dc.publisher.place | United States | - |
dc.identifier.issnl | 0894-7317 | - |