Article: Abdominal submuscular implant of subcutaneous implantable cardioverter-defibrillator in a young child
Title | Abdominal submuscular implant of subcutaneous implantable cardioverter-defibrillator in a young child |
---|---|
Authors | |
Keywords | child abdomen subcutaneous icd implants |
Issue Date | 2018 |
Publisher | Oxford University Press. The Journal's web site is located at http://europace.oxfordjournals.org/ |
Citation | EP Europace, 2018, v. 20 n. FI2, p. f248-f248 How to Cite? |
Abstract | We describe the abdominal submuscular implant of the subcutaneous implantable cardioverter-defibrillator (S-ICD) in a 4-year-old girl (20 kg) with aborted ventricular fibrillation cardiac arrest. With parental wish, S-ICD was chosen to be implanted after detailed discussion. The abdominal pocket was created between the external oblique and internal oblique muscle layers, over the left side of her abdomen. Using 3-incision technique, the electrode coil was implanted with the use of tunnelling device. The coil was placed with a slack subcutaneously over the sternum, as illustrated in the radiograph shown in Figure. Defibrillation threshold testing successfully passed. Two-month post implantation she had an episode of ventricular tachycardia successfully cardioverted by ICD shock. |
Description | Link to Free access |
Persistent Identifier | http://hdl.handle.net/10722/283272 |
ISSN | 2023 Impact Factor: 7.9 2023 SCImago Journal Rankings: 2.895 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kwok, SY | - |
dc.contributor.author | Yam, N | - |
dc.contributor.author | Lun, KS | - |
dc.contributor.author | Chen, RHS | - |
dc.contributor.author | Au, TWK | - |
dc.contributor.author | Yung, TC | - |
dc.date.accessioned | 2020-06-22T02:54:24Z | - |
dc.date.available | 2020-06-22T02:54:24Z | - |
dc.date.issued | 2018 | - |
dc.identifier.citation | EP Europace, 2018, v. 20 n. FI2, p. f248-f248 | - |
dc.identifier.issn | 1099-5129 | - |
dc.identifier.uri | http://hdl.handle.net/10722/283272 | - |
dc.description | Link to Free access | - |
dc.description.abstract | We describe the abdominal submuscular implant of the subcutaneous implantable cardioverter-defibrillator (S-ICD) in a 4-year-old girl (20 kg) with aborted ventricular fibrillation cardiac arrest. With parental wish, S-ICD was chosen to be implanted after detailed discussion. The abdominal pocket was created between the external oblique and internal oblique muscle layers, over the left side of her abdomen. Using 3-incision technique, the electrode coil was implanted with the use of tunnelling device. The coil was placed with a slack subcutaneously over the sternum, as illustrated in the radiograph shown in Figure. Defibrillation threshold testing successfully passed. Two-month post implantation she had an episode of ventricular tachycardia successfully cardioverted by ICD shock. | - |
dc.language | eng | - |
dc.publisher | Oxford University Press. The Journal's web site is located at http://europace.oxfordjournals.org/ | - |
dc.relation.ispartof | EP Europace | - |
dc.rights | Pre-print: Journal Title] ©: [year] [owner as specified on the article] Published by Oxford University Press [on behalf of xxxxxx]. All rights reserved. Pre-print (Once an article is published, preprint notice should be amended to): This is an electronic version of an article published in [include the complete citation information for the final version of the Article as published in the print edition of the Journal.] Post-print: This is a pre-copy-editing, author-produced PDF of an article accepted for publication in [insert journal title] following peer review. The definitive publisher-authenticated version [insert complete citation information here] is available online at: xxxxxxx [insert URL that the author will receive upon publication here]. | - |
dc.subject | child | - |
dc.subject | abdomen | - |
dc.subject | subcutaneous icd | - |
dc.subject | implants | - |
dc.title | Abdominal submuscular implant of subcutaneous implantable cardioverter-defibrillator in a young child | - |
dc.type | Article | - |
dc.identifier.email | Lun, KS: lunks@hkucc.hku.hk | - |
dc.identifier.email | Chen, RHS: rhschen@hku.hk | - |
dc.identifier.email | Au, TWK: auwkt@hkucc.hku.hk | - |
dc.identifier.email | Yung, TC: tcyung@hkusua.hku.hk | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1093/europace/euy001 | - |
dc.identifier.pmid | 29401320 | - |
dc.identifier.scopus | eid_2-s2.0-85061116949 | - |
dc.identifier.hkuros | 310480 | - |
dc.identifier.volume | 20 | - |
dc.identifier.issue | FI2 | - |
dc.identifier.spage | f248 | - |
dc.identifier.epage | f248 | - |
dc.identifier.isi | WOS:000450396600023 | - |
dc.publisher.place | United Kingdom | - |
dc.identifier.issnl | 1099-5129 | - |