Conference Paper: Development of a new method for calibrating an angular accelerometer using a calibration table

TitleDevelopment of a new method for calibrating an angular accelerometer using a calibration table
Authors
Issue Date2015
Citation
AIAA Guidance, Navigation, and Control Conference 2015 (MGNC 2015), Kissimmee, FL, 5-9 January 2015. In Conference Proceedings, 2015 How to Cite?
AbstractAngular Accelerometers (AA) directly measure angular accelerations, in contrast to the traditional approach which requires calculating the angular accelerations by differentiating the angular rates from rate gyroscopes. Whereas very accurate and robust, AA are physical measuring devices, which means that they could have construction and alignment imperfections that affect their outputs. In this paper, AA sensor's output was verified in order to meet a standard reference, achieved by means of an off-line calibration method. To begin with, a laboratory measurement with a customized input sequence was conducted using a high precision calibration table as a reference. The angular acceleration reference signal, however, was not measured directly by the calibration table, but instead calculated from a position reference using a second order differentiator. Inherently, the noise in the position measurements was significantly amplified, leading to an angular acceleration reference that cannot be used directly. A non-linear extended state observer was developed to estimate a more accurate acceleration reference. Subsequently, a calibration model covering the entire domain was identified based on a least-squares approach. This paper improves calibration table angular acceleration data and provides a method to calibrate the new type of angular acceleration sensor.
Persistent Identifierhttp://hdl.handle.net/10722/288705

 

DC FieldValueLanguage
dc.contributor.authorJatiningrum, D.-
dc.contributor.authorLu, P.-
dc.contributor.authorde Visser, C. C.-
dc.contributor.authorChu, Q. P.-
dc.contributor.authorMulder, M.-
dc.date.accessioned2020-10-12T08:05:39Z-
dc.date.available2020-10-12T08:05:39Z-
dc.date.issued2015-
dc.identifier.citationAIAA Guidance, Navigation, and Control Conference 2015 (MGNC 2015), Kissimmee, FL, 5-9 January 2015. In Conference Proceedings, 2015-
dc.identifier.urihttp://hdl.handle.net/10722/288705-
dc.description.abstractAngular Accelerometers (AA) directly measure angular accelerations, in contrast to the traditional approach which requires calculating the angular accelerations by differentiating the angular rates from rate gyroscopes. Whereas very accurate and robust, AA are physical measuring devices, which means that they could have construction and alignment imperfections that affect their outputs. In this paper, AA sensor's output was verified in order to meet a standard reference, achieved by means of an off-line calibration method. To begin with, a laboratory measurement with a customized input sequence was conducted using a high precision calibration table as a reference. The angular acceleration reference signal, however, was not measured directly by the calibration table, but instead calculated from a position reference using a second order differentiator. Inherently, the noise in the position measurements was significantly amplified, leading to an angular acceleration reference that cannot be used directly. A non-linear extended state observer was developed to estimate a more accurate acceleration reference. Subsequently, a calibration model covering the entire domain was identified based on a least-squares approach. This paper improves calibration table angular acceleration data and provides a method to calibrate the new type of angular acceleration sensor.-
dc.languageeng-
dc.relation.ispartofAIAA Guidance, Navigation, and Control Conference-
dc.titleDevelopment of a new method for calibrating an angular accelerometer using a calibration table-
dc.typeConference_Paper-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.2514/6.2015-0331-