File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1287/opre.2017.1660
- Scopus: eid_2-s2.0-85044465476
- WOS: WOS:000427717400005
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Robust defibrillator deployment under cardiac arrest location uncertainty via row-and-column generation
Title | Robust defibrillator deployment under cardiac arrest location uncertainty via row-and-column generation |
---|---|
Authors | |
Keywords | Facility location Row-and-column generation Healthcare operations Robust optimization |
Issue Date | 2018 |
Citation | Operations Research, 2018, v. 66, n. 2, p. 358-379 How to Cite? |
Abstract | © 2018 INFORMS. Sudden cardiac arrest is a significant public health concern. Successful treatment of cardiac arrest is extremely time sensitive, and use of an automated external defibrillator (AED) where possible significantly increases the probability of survival. Placement of AEDs in public locations can improve survival by enabling bystanders to treat victims of cardiac arrest prior to the arrival of emergency medical responders, thus shortening the time between collapse and treatment. However, since the exact locations of future cardiac arrests cannot be known a priori, AEDs must be placed strategically in public locations to ensure their accessibility in the event of an out-of-hospital cardiac arrest emergency. In this paper, we propose a data-driven optimization model for deploying AEDs in public spaces while accounting for uncertainty in future cardiac arrest locations. Our approach involves discretizing a continuous service area into a large set of scenarios, where the probability of cardiac arrest at each location is itself uncertain. We model uncertainty in the spatial risk of cardiac arrest using a polyhedral uncertainty set that we calibrate using historical cardiac arrest data. We propose a solution technique based on row-and-column generation that exploits the structure of the uncertainty set, allowing the algorithm to scale gracefully with the total number of scenarios. Using real cardiac arrest data from the City of Toronto, we conduct an extensive numerical study on AED deployment public locations. We find that hedging against cardiac arrest location uncertainty can produce AED deployments that outperform an intuitive sample average approximation by 9%-15% and cuts the performance gap with respect to an ex post model by half. Our findings suggest that accounting for cardiac arrest location uncertainty can lead to improved accessibility of AEDs during cardiac arrest emergencies and the potential for improved survival outcomes. |
Persistent Identifier | http://hdl.handle.net/10722/296166 |
ISSN | 2023 Impact Factor: 2.2 2023 SCImago Journal Rankings: 2.848 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chan, Timothy C.Y. | - |
dc.contributor.author | Shen, Zuo Jun Max | - |
dc.contributor.author | Siddiq, Auyon | - |
dc.date.accessioned | 2021-02-11T04:52:58Z | - |
dc.date.available | 2021-02-11T04:52:58Z | - |
dc.date.issued | 2018 | - |
dc.identifier.citation | Operations Research, 2018, v. 66, n. 2, p. 358-379 | - |
dc.identifier.issn | 0030-364X | - |
dc.identifier.uri | http://hdl.handle.net/10722/296166 | - |
dc.description.abstract | © 2018 INFORMS. Sudden cardiac arrest is a significant public health concern. Successful treatment of cardiac arrest is extremely time sensitive, and use of an automated external defibrillator (AED) where possible significantly increases the probability of survival. Placement of AEDs in public locations can improve survival by enabling bystanders to treat victims of cardiac arrest prior to the arrival of emergency medical responders, thus shortening the time between collapse and treatment. However, since the exact locations of future cardiac arrests cannot be known a priori, AEDs must be placed strategically in public locations to ensure their accessibility in the event of an out-of-hospital cardiac arrest emergency. In this paper, we propose a data-driven optimization model for deploying AEDs in public spaces while accounting for uncertainty in future cardiac arrest locations. Our approach involves discretizing a continuous service area into a large set of scenarios, where the probability of cardiac arrest at each location is itself uncertain. We model uncertainty in the spatial risk of cardiac arrest using a polyhedral uncertainty set that we calibrate using historical cardiac arrest data. We propose a solution technique based on row-and-column generation that exploits the structure of the uncertainty set, allowing the algorithm to scale gracefully with the total number of scenarios. Using real cardiac arrest data from the City of Toronto, we conduct an extensive numerical study on AED deployment public locations. We find that hedging against cardiac arrest location uncertainty can produce AED deployments that outperform an intuitive sample average approximation by 9%-15% and cuts the performance gap with respect to an ex post model by half. Our findings suggest that accounting for cardiac arrest location uncertainty can lead to improved accessibility of AEDs during cardiac arrest emergencies and the potential for improved survival outcomes. | - |
dc.language | eng | - |
dc.relation.ispartof | Operations Research | - |
dc.subject | Facility location | - |
dc.subject | Row-and-column generation | - |
dc.subject | Healthcare operations | - |
dc.subject | Robust optimization | - |
dc.title | Robust defibrillator deployment under cardiac arrest location uncertainty via row-and-column generation | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1287/opre.2017.1660 | - |
dc.identifier.scopus | eid_2-s2.0-85044465476 | - |
dc.identifier.volume | 66 | - |
dc.identifier.issue | 2 | - |
dc.identifier.spage | 358 | - |
dc.identifier.epage | 379 | - |
dc.identifier.eissn | 1526-5463 | - |
dc.identifier.isi | WOS:000427717400005 | - |
dc.identifier.issnl | 0030-364X | - |