File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/j.jhazmat.2021.126799
- Scopus: eid_2-s2.0-85113257762
- WOS: WOS:000696928200001
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Aerosol transmission of SARS-CoV-2 due to the chimney effect in two high-rise housing drainage stacks
Title | Aerosol transmission of SARS-CoV-2 due to the chimney effect in two high-rise housing drainage stacks |
---|---|
Authors | |
Keywords | COVID-19 Fecal aerosol Drainage system Chimney effect Spitting behavior |
Issue Date | 2022 |
Publisher | Elsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/jhazmat |
Citation | Journal of Hazardous Materials, 2022, v. 421, p. article no. 126799 How to Cite? |
Abstract | Stack aerosols are generated within vertical building drainage stacks during the discharge of wastewater containing feces and exhaled mucus from toilets and washbasins. Fifteen stack aerosol-related outbreaks of coronavirus disease 2019 (COVID-19) in high-rise buildings have been observed in Hong Kong and Guangzhou. Currently, we investigated two such outbreaks of COVID-19 in Hong Kong, identified the probable role of chimney effect-induced airflow in a building drainage system in the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). We injected tracer gas (SF6) into the drainage stacks via the water closet of the index case and monitored tracer gas concentrations in the bathrooms and along the facades of infected and non-infected flats and in roof vents. The air temperature, humidity, and pressure in vertical stacks were also monitored. The measured tracer gas distribution agreed with the observed distribution of the infected cases. Phylogenetic analysis of the SARS-CoV-2 genome sequences demonstrated clonal spread from a point source in cases along the same vertical column. The stack air pressure and temperature distributions suggested that stack aerosols can spread to indoors through pipe leaks which provide direct evidence for the long-range aerosol transmission of SARS-CoV-2 through drainage pipes via the chimney effect. |
Persistent Identifier | http://hdl.handle.net/10722/301526 |
ISSN | 2023 Impact Factor: 12.2 2023 SCImago Journal Rankings: 2.950 |
PubMed Central ID | |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wang, Q | - |
dc.contributor.author | Li, Y | - |
dc.contributor.author | Lung, D | - |
dc.contributor.author | CHAN, PT | - |
dc.contributor.author | Dung, CH | - |
dc.contributor.author | JIA, W | - |
dc.contributor.author | MIAO, T | - |
dc.contributor.author | Huang, J | - |
dc.contributor.author | CHEN, W | - |
dc.contributor.author | WANG, Z | - |
dc.contributor.author | Leung, KM | - |
dc.contributor.author | Lin, Z | - |
dc.contributor.author | Wong, D | - |
dc.contributor.author | Tse, H | - |
dc.contributor.author | Wong, SCY | - |
dc.contributor.author | Choi, GKY | - |
dc.contributor.author | Lam, JYW | - |
dc.contributor.author | To, KKW | - |
dc.contributor.author | Cheng, VCC | - |
dc.contributor.author | Yuen, KY | - |
dc.date.accessioned | 2021-08-09T03:40:21Z | - |
dc.date.available | 2021-08-09T03:40:21Z | - |
dc.date.issued | 2022 | - |
dc.identifier.citation | Journal of Hazardous Materials, 2022, v. 421, p. article no. 126799 | - |
dc.identifier.issn | 0304-3894 | - |
dc.identifier.uri | http://hdl.handle.net/10722/301526 | - |
dc.description.abstract | Stack aerosols are generated within vertical building drainage stacks during the discharge of wastewater containing feces and exhaled mucus from toilets and washbasins. Fifteen stack aerosol-related outbreaks of coronavirus disease 2019 (COVID-19) in high-rise buildings have been observed in Hong Kong and Guangzhou. Currently, we investigated two such outbreaks of COVID-19 in Hong Kong, identified the probable role of chimney effect-induced airflow in a building drainage system in the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). We injected tracer gas (SF6) into the drainage stacks via the water closet of the index case and monitored tracer gas concentrations in the bathrooms and along the facades of infected and non-infected flats and in roof vents. The air temperature, humidity, and pressure in vertical stacks were also monitored. The measured tracer gas distribution agreed with the observed distribution of the infected cases. Phylogenetic analysis of the SARS-CoV-2 genome sequences demonstrated clonal spread from a point source in cases along the same vertical column. The stack air pressure and temperature distributions suggested that stack aerosols can spread to indoors through pipe leaks which provide direct evidence for the long-range aerosol transmission of SARS-CoV-2 through drainage pipes via the chimney effect. | - |
dc.language | eng | - |
dc.publisher | Elsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/jhazmat | - |
dc.relation.ispartof | Journal of Hazardous Materials | - |
dc.subject | COVID-19 | - |
dc.subject | Fecal aerosol | - |
dc.subject | Drainage system | - |
dc.subject | Chimney effect | - |
dc.subject | Spitting behavior | - |
dc.title | Aerosol transmission of SARS-CoV-2 due to the chimney effect in two high-rise housing drainage stacks | - |
dc.type | Article | - |
dc.identifier.email | Wang, Q: wangqun3@hku.hk | - |
dc.identifier.email | Li, Y: liyg@hku.hk | - |
dc.identifier.email | Huang, J: jxhuang@hku.hk | - |
dc.identifier.email | Yuen, KY: kyyuen@hkucc.hku.hk | - |
dc.identifier.authority | Li, Y=rp00151 | - |
dc.identifier.authority | Huang, J=rp01758 | - |
dc.identifier.authority | Yuen, KY=rp00366 | - |
dc.description.nature | link_to_OA_fulltext | - |
dc.identifier.doi | 10.1016/j.jhazmat.2021.126799 | - |
dc.identifier.pmcid | PMC8327615 | - |
dc.identifier.scopus | eid_2-s2.0-85113257762 | - |
dc.identifier.hkuros | 324048 | - |
dc.identifier.volume | 421 | - |
dc.identifier.spage | article no. 126799 | - |
dc.identifier.epage | article no. 126799 | - |
dc.identifier.isi | WOS:000696928200001 | - |
dc.publisher.place | Netherlands | - |