Conference Paper: Acousticcardiogram: Monitoring Heartbeats using Acoustic Signals on Smart Devices

TitleAcousticcardiogram: Monitoring Heartbeats using Acoustic Signals on Smart Devices
Authors
Issue Date2018
Citation
Proceedings - IEEE INFOCOM, 2018, v. 2018-April, p. 1574-1582 How to Cite?
AbstractVital signs such as heart rate and heartbeat interval are currently measured by electrocardiograms (ECG) or wearable physiological monitors. These techniques either require contact with the patient's skin or are usually uncomfortable to wear, rendering them too expensive and user-unfriendly for daily monitoring. In this paper, we propose a new noninvasive technology to generate an Acousticcardiogram (ACG) that precisely monitors heartbeats using inaudible acoustic signals. ACG uses only commodity microphones and speakers commonly equipped on ubiquitous off-the-shelf devices, such as smartphones and laptops. By transmitting an acoustic signal and analyzing its reflections off human body, ACG is capable of recognizing the heart rate as well as heartbeat rhythm. We employ frequency-modulated sound signals to separate reflection of heart from that of background motions and breath, and continuously track the phase changes of the acoustic data. To translate these acoustic data into heart and breath rates, we leverage the dual microphone design on COTS mobile devices to suppress direct echo from speaker to microphones, identify heart rate in frequency domain, and adopt an advanced algorithm to extract individual heartbeats. We implement ACG on commercial devices and validate its performance in real environments. Experimental results demonstrate ACG monitors user's heartbeat accurately, with median heart rate estimation error of 0.6 beat per minute (bpm), and median heartbeat interval estimation error of 19 ms.
Persistent Identifierhttp://hdl.handle.net/10722/303868
ISSN
2020 SCImago Journal Rankings: 1.183
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorQian, Kun-
dc.contributor.authorWu, Chenshu-
dc.contributor.authorXiao, Fu-
dc.contributor.authorZheng, Yue-
dc.contributor.authorZhang, Yi-
dc.contributor.authorYang, Zheng-
dc.contributor.authorLiu, Yunhao-
dc.date.accessioned2021-09-15T08:26:10Z-
dc.date.available2021-09-15T08:26:10Z-
dc.date.issued2018-
dc.identifier.citationProceedings - IEEE INFOCOM, 2018, v. 2018-April, p. 1574-1582-
dc.identifier.issn0743-166X-
dc.identifier.urihttp://hdl.handle.net/10722/303868-
dc.description.abstractVital signs such as heart rate and heartbeat interval are currently measured by electrocardiograms (ECG) or wearable physiological monitors. These techniques either require contact with the patient's skin or are usually uncomfortable to wear, rendering them too expensive and user-unfriendly for daily monitoring. In this paper, we propose a new noninvasive technology to generate an Acousticcardiogram (ACG) that precisely monitors heartbeats using inaudible acoustic signals. ACG uses only commodity microphones and speakers commonly equipped on ubiquitous off-the-shelf devices, such as smartphones and laptops. By transmitting an acoustic signal and analyzing its reflections off human body, ACG is capable of recognizing the heart rate as well as heartbeat rhythm. We employ frequency-modulated sound signals to separate reflection of heart from that of background motions and breath, and continuously track the phase changes of the acoustic data. To translate these acoustic data into heart and breath rates, we leverage the dual microphone design on COTS mobile devices to suppress direct echo from speaker to microphones, identify heart rate in frequency domain, and adopt an advanced algorithm to extract individual heartbeats. We implement ACG on commercial devices and validate its performance in real environments. Experimental results demonstrate ACG monitors user's heartbeat accurately, with median heart rate estimation error of 0.6 beat per minute (bpm), and median heartbeat interval estimation error of 19 ms.-
dc.languageeng-
dc.relation.ispartofProceedings - IEEE INFOCOM-
dc.titleAcousticcardiogram: Monitoring Heartbeats using Acoustic Signals on Smart Devices-
dc.typeConference_Paper-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1109/INFOCOM.2018.8485978-
dc.identifier.scopuseid_2-s2.0-85056186960-
dc.identifier.volume2018-April-
dc.identifier.spage1574-
dc.identifier.epage1582-