File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Metal artifact reduction in 2D CT images with self-supervised cross-domain learning

TitleMetal artifact reduction in 2D CT images with self-supervised cross-domain learning
Authors
Keywordscross-domain learning
deep learning
metal artifact reduction
sinogram inpaintin
Issue Date2021
PublisherInstitute of Physics Publishing. The Journal's web site is located at http://www.iop.org/journals/pmb
Citation
Physics in Medicine and Biology, 2021, v. 66 n. 17, article no. 175003 How to Cite?
AbstractThe presence of metallic implants often introduces severe metal artifacts in the x-ray computed tomography (CT) images, which could adversely influence clinical diagnosis or dose calculation in radiation therapy. In this work, we present a novel deep-learning-based approach for metal artifact reduction (MAR). In order to alleviate the need for anatomically identical CT image pairs (i.e. metal artifact-corrupted CT image and metal artifact-free CT image) for network learning, we propose a self-supervised cross-domain learning framework. Specifically, we train a neural network to restore the metal trace region values in the given metal-free sinogram, where the metal trace is identified by the forward projection of metal masks. We then design a novel filtered backward projection (FBP) reconstruction loss to encourage the network to generate more perfect completion results and a residual-learning-based image refinement module to reduce the secondary artifacts in the reconstructed CT images. To preserve the fine structure details and fidelity of the final MAR image, instead of directly adopting convolutional neural network (CNN)-refined images as output, we incorporate the metal trace replacement into our framework and replace the metal-affected projections of the original sinogram with the prior sinogram generated by the forward projection of the CNN output. We then use the FBP algorithms for final MAR image reconstruction. We conduct an extensive evaluation on simulated and real artifact data to show the effectiveness of our design. Our method produces superior MAR results and outperforms other compelling methods. We also demonstrate the potential of our framework for other organ sites.
Persistent Identifierhttp://hdl.handle.net/10722/304299
ISSN
2021 Impact Factor: 4.174
2020 SCImago Journal Rankings: 1.312
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorYu, L-
dc.contributor.authorZhang, Z-
dc.contributor.authorLi, X-
dc.contributor.authorRen, H-
dc.contributor.authorZhao, W-
dc.contributor.authorXing, L-
dc.date.accessioned2021-09-23T08:58:05Z-
dc.date.available2021-09-23T08:58:05Z-
dc.date.issued2021-
dc.identifier.citationPhysics in Medicine and Biology, 2021, v. 66 n. 17, article no. 175003-
dc.identifier.issn0031-9155-
dc.identifier.urihttp://hdl.handle.net/10722/304299-
dc.description.abstractThe presence of metallic implants often introduces severe metal artifacts in the x-ray computed tomography (CT) images, which could adversely influence clinical diagnosis or dose calculation in radiation therapy. In this work, we present a novel deep-learning-based approach for metal artifact reduction (MAR). In order to alleviate the need for anatomically identical CT image pairs (i.e. metal artifact-corrupted CT image and metal artifact-free CT image) for network learning, we propose a self-supervised cross-domain learning framework. Specifically, we train a neural network to restore the metal trace region values in the given metal-free sinogram, where the metal trace is identified by the forward projection of metal masks. We then design a novel filtered backward projection (FBP) reconstruction loss to encourage the network to generate more perfect completion results and a residual-learning-based image refinement module to reduce the secondary artifacts in the reconstructed CT images. To preserve the fine structure details and fidelity of the final MAR image, instead of directly adopting convolutional neural network (CNN)-refined images as output, we incorporate the metal trace replacement into our framework and replace the metal-affected projections of the original sinogram with the prior sinogram generated by the forward projection of the CNN output. We then use the FBP algorithms for final MAR image reconstruction. We conduct an extensive evaluation on simulated and real artifact data to show the effectiveness of our design. Our method produces superior MAR results and outperforms other compelling methods. We also demonstrate the potential of our framework for other organ sites.-
dc.languageeng-
dc.publisherInstitute of Physics Publishing. The Journal's web site is located at http://www.iop.org/journals/pmb-
dc.relation.ispartofPhysics in Medicine and Biology-
dc.rightsPhysics in Medicine and Biology. Copyright © Institute of Physics Publishing.-
dc.subjectcross-domain learning-
dc.subjectdeep learning-
dc.subjectmetal artifact reduction-
dc.subjectsinogram inpaintin-
dc.titleMetal artifact reduction in 2D CT images with self-supervised cross-domain learning-
dc.typeArticle-
dc.identifier.emailYu, L: lqyu@hku.hk-
dc.identifier.authorityYu, L=rp02814-
dc.identifier.doi10.1088/1361-6560/ac195c-
dc.identifier.pmid34330119-
dc.identifier.scopuseid_2-s2.0-85114404597-
dc.identifier.hkuros325083-
dc.identifier.volume66-
dc.identifier.issue17-
dc.identifier.spagearticle no. 175003-
dc.identifier.epagearticle no. 175003-
dc.identifier.isiWOS:000687393400001-
dc.publisher.placeUnited Kingdom-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats