Article: The effect of different light curing units on Vickers microhardness and degree of conversion of flowable resin composites
Title | The effect of different light curing units on Vickers microhardness and degree of conversion of flowable resin composites |
---|---|
Authors | |
Keywords | Light curing units Flowable resin composites Vickers microhardness Degree of conversion Polymerization efficacy |
Issue Date | 2021 |
Publisher | Nihon Shika Riko Gakkai. The Journal's web site is located at http://www.jsdmd.jp/allpdf.html |
Citation | Dental Materials Journal, 2021, v. 40 n. 1, p. 44-51 How to Cite? |
Abstract | This study aimed to assess the influence of different light curing units (LCUs) on the polymerization of various flowable resin composites. Three LCUs (Optilux 501, Elipar™ DeepCure-L LED and Bluephase®20i) and eight flowable resin composites: MI FIL Flow, Estelite Flow Quick, Estelite Universal Flow (medium), Estelite Universal Flow (super low), Beautifil Flow Plus, Clearfil Majesty ES Flow, Filtek Supreme Ultra flowable and TetricEvo Flow were tested. For Vickers microhardness (VHN) test and degree of conversion (DC), specimens were prepared and polymerized for 20 s. VHN test was performed at top surfaces (3 indentations) and DC for each specimen was measured using Fourier transform infrared (FT-IR) spectroscopy after 24 h dry storage in dark at 37˚C. The data were analyzed with 2-way ANOVA and t-test with Bonferroni correction. DC and hardness values showed a relationship between materials and LCUs. The curing efficacy of LCU type may depend on the material composition. |
Description | Bronze open access |
Persistent Identifier | http://hdl.handle.net/10722/306475 |
ISSN | 2023 Impact Factor: 1.9 2023 SCImago Journal Rankings: 0.589 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Aung, SZ | - |
dc.contributor.author | Takagaki, T | - |
dc.contributor.author | Ikeda, M | - |
dc.contributor.author | Nozaki, K | - |
dc.contributor.author | Burrow, MF | - |
dc.contributor.author | Abdou, A | - |
dc.contributor.author | Nikaido, T | - |
dc.contributor.author | Tagami, J | - |
dc.date.accessioned | 2021-10-22T07:35:08Z | - |
dc.date.available | 2021-10-22T07:35:08Z | - |
dc.date.issued | 2021 | - |
dc.identifier.citation | Dental Materials Journal, 2021, v. 40 n. 1, p. 44-51 | - |
dc.identifier.issn | 0287-4547 | - |
dc.identifier.uri | http://hdl.handle.net/10722/306475 | - |
dc.description | Bronze open access | - |
dc.description.abstract | This study aimed to assess the influence of different light curing units (LCUs) on the polymerization of various flowable resin composites. Three LCUs (Optilux 501, Elipar™ DeepCure-L LED and Bluephase®20i) and eight flowable resin composites: MI FIL Flow, Estelite Flow Quick, Estelite Universal Flow (medium), Estelite Universal Flow (super low), Beautifil Flow Plus, Clearfil Majesty ES Flow, Filtek Supreme Ultra flowable and TetricEvo Flow were tested. For Vickers microhardness (VHN) test and degree of conversion (DC), specimens were prepared and polymerized for 20 s. VHN test was performed at top surfaces (3 indentations) and DC for each specimen was measured using Fourier transform infrared (FT-IR) spectroscopy after 24 h dry storage in dark at 37˚C. The data were analyzed with 2-way ANOVA and t-test with Bonferroni correction. DC and hardness values showed a relationship between materials and LCUs. The curing efficacy of LCU type may depend on the material composition. | - |
dc.language | eng | - |
dc.publisher | Nihon Shika Riko Gakkai. The Journal's web site is located at http://www.jsdmd.jp/allpdf.html | - |
dc.relation.ispartof | Dental Materials Journal | - |
dc.subject | Light curing units | - |
dc.subject | Flowable resin composites | - |
dc.subject | Vickers microhardness | - |
dc.subject | Degree of conversion | - |
dc.subject | Polymerization efficacy | - |
dc.title | The effect of different light curing units on Vickers microhardness and degree of conversion of flowable resin composites | - |
dc.type | Article | - |
dc.identifier.email | Burrow, MF: mfburr58@hku.hk | - |
dc.identifier.authority | Burrow, MF=rp01306 | - |
dc.description.nature | link_to_OA_fulltext | - |
dc.identifier.doi | 10.4012/dmj.2019-353 | - |
dc.identifier.pmid | 32848103 | - |
dc.identifier.scopus | eid_2-s2.0-85100349839 | - |
dc.identifier.hkuros | 328981 | - |
dc.identifier.volume | 40 | - |
dc.identifier.issue | 1 | - |
dc.identifier.spage | 44 | - |
dc.identifier.epage | 51 | - |
dc.identifier.isi | WOS:000641451800006 | - |
dc.publisher.place | Japan | - |