File Download
  Links for fulltext
     (May Require Subscription)
Supplementary

Conference Paper: OSC7: Development of Prescale Film for Occlusal Force Analysis: A Pilot Study

TitleOSC7: Development of Prescale Film for Occlusal Force Analysis: A Pilot Study
Authors
Issue Date2018
PublisherMedknow.
Citation
11th Biennial Congress of Asian Academy of Prosthodontics, Kuala Lumpur, Malaysia, 21-23 September 2018. In Journal of Indian Prosthodontic Society, 2018, v. 18, n. suppl. 1, p. S9-S10 How to Cite?
AbstractAim: The aim of this study was to devise and optimise a design of pressure sensitive sheet known as Prescale film (Fujifilm Corp. Kuala Lumpur, Malaysia) for occlusal force analysis at the dental office and to compare occlusal forces using Prescale film with and without disposable polyethylene (PE) sleeve. Materials and methods: The development of Prescale film for occlusal force measurement initiated with the design of the film into horseshoe shape according to shape of the arches, and the film is fully covered by PE sleeve for hygienic reason. 10 dentate patients (27 to 44 year-old) were recruited in this pilot study. All patients were asked to bite on these two types of designs (Group A: with PE sleeve; Group B: without PE sleeve) and mean values were recorded. The films were calibrated for analysis using Pressure Distribution Mapping System FPD-8010E software (Fujifilm Corp., Tokyo, Japan). The data were statistically analysed using Wilcoxon signed rank test in SPSS version 23.0 statistical software. Results: The occlusal forces for Group A and Group B varied widely from 191.0N to 625.0N and from 197.0N to 609.0N respectively. However, no significance difference was found between these two groups, p value was 0.706 (p > 0.05). Conclusion: This finding proposed that Prescale film with PE sleeve can be used as a novel design to measure the occlusal forces of patients due to its accuracy, simplicity, hygienic, cost effective and easy to handle.
Persistent Identifierhttp://hdl.handle.net/10722/315480
ISSN
2023 Impact Factor: 1.0
2023 SCImago Journal Rankings: 0.386
PubMed Central ID

 

DC FieldValueLanguage
dc.contributor.authorIdris, RI-
dc.contributor.authorTasri, NI-
dc.contributor.authorYusof, SF-
dc.contributor.authorShoji, Y-
dc.contributor.authorLim, TW-
dc.date.accessioned2022-08-19T08:39:25Z-
dc.date.available2022-08-19T08:39:25Z-
dc.date.issued2018-
dc.identifier.citation11th Biennial Congress of Asian Academy of Prosthodontics, Kuala Lumpur, Malaysia, 21-23 September 2018. In Journal of Indian Prosthodontic Society, 2018, v. 18, n. suppl. 1, p. S9-S10-
dc.identifier.issn0972-4052-
dc.identifier.urihttp://hdl.handle.net/10722/315480-
dc.description.abstractAim: The aim of this study was to devise and optimise a design of pressure sensitive sheet known as Prescale film (Fujifilm Corp. Kuala Lumpur, Malaysia) for occlusal force analysis at the dental office and to compare occlusal forces using Prescale film with and without disposable polyethylene (PE) sleeve. Materials and methods: The development of Prescale film for occlusal force measurement initiated with the design of the film into horseshoe shape according to shape of the arches, and the film is fully covered by PE sleeve for hygienic reason. 10 dentate patients (27 to 44 year-old) were recruited in this pilot study. All patients were asked to bite on these two types of designs (Group A: with PE sleeve; Group B: without PE sleeve) and mean values were recorded. The films were calibrated for analysis using Pressure Distribution Mapping System FPD-8010E software (Fujifilm Corp., Tokyo, Japan). The data were statistically analysed using Wilcoxon signed rank test in SPSS version 23.0 statistical software. Results: The occlusal forces for Group A and Group B varied widely from 191.0N to 625.0N and from 197.0N to 609.0N respectively. However, no significance difference was found between these two groups, p value was 0.706 (p > 0.05). Conclusion: This finding proposed that Prescale film with PE sleeve can be used as a novel design to measure the occlusal forces of patients due to its accuracy, simplicity, hygienic, cost effective and easy to handle.-
dc.languageeng-
dc.publisherMedknow.-
dc.relation.ispartofJournal of Indian Prosthodontic Society-
dc.titleOSC7: Development of Prescale Film for Occlusal Force Analysis: A Pilot Study-
dc.typeConference_Paper-
dc.description.natureabstract-
dc.identifier.doi10.4103/0972-4052.244596-
dc.identifier.pmid30532399-
dc.identifier.pmcidPMC6238523-
dc.identifier.scopuseid_2-s2.0-85103499553-
dc.identifier.volume18-
dc.identifier.issuesuppl. 1-
dc.identifier.spageS9-
dc.identifier.epageS10-
dc.publisher.placeKuala Lumpur, Malaysia-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats