File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1148/radiol.2253011871
- Scopus: eid_2-s2.0-0036891972
- PMID: 12461277
- WOS: WOS:000179420800039
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Coronary artery calcium measurement with multi-detector row CT: In vitro assessment of effect of radiation dose
Title | Coronary artery calcium measurement with multi-detector row CT: In vitro assessment of effect of radiation dose |
---|---|
Authors | |
Keywords | Computed tomography (CT), radiation exposure Coronary vessels, calcification Coronary vessels, CT |
Issue Date | 2002 |
Citation | Radiology, 2002, v. 225, n. 3, p. 901-906 How to Cite? |
Abstract | The authors assessed in vitro the effect of radiation dose on coronary artery calcium quantification with multi-detector row computed tomography. A cardiac phantom with calcified cylinders was scanned at various milliampere second settings (20-160 mAs). A clear tendency was found for image noise to decrease as tube current increased (P < .001). No tendency was found for the Agatson score or calcium volume and mass errors to vary with tube current. Calcium measurements were not significantly affected by the choice of tube current. Calcium mass error was strongly correlated with calcium volume error (P < .001). The calcium mass measurement was more accurate and less variable than the calcium volume measurement. © RSNA, 2002. |
Persistent Identifier | http://hdl.handle.net/10722/315926 |
ISSN | 2023 Impact Factor: 12.1 2023 SCImago Journal Rankings: 3.692 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Hong, Cheng | - |
dc.contributor.author | Bae, Kyongtae T. | - |
dc.contributor.author | Pilgram, Thomas K. | - |
dc.contributor.author | Suh, Jongdae | - |
dc.contributor.author | Bradley, David | - |
dc.date.accessioned | 2022-08-24T15:48:37Z | - |
dc.date.available | 2022-08-24T15:48:37Z | - |
dc.date.issued | 2002 | - |
dc.identifier.citation | Radiology, 2002, v. 225, n. 3, p. 901-906 | - |
dc.identifier.issn | 0033-8419 | - |
dc.identifier.uri | http://hdl.handle.net/10722/315926 | - |
dc.description.abstract | The authors assessed in vitro the effect of radiation dose on coronary artery calcium quantification with multi-detector row computed tomography. A cardiac phantom with calcified cylinders was scanned at various milliampere second settings (20-160 mAs). A clear tendency was found for image noise to decrease as tube current increased (P < .001). No tendency was found for the Agatson score or calcium volume and mass errors to vary with tube current. Calcium measurements were not significantly affected by the choice of tube current. Calcium mass error was strongly correlated with calcium volume error (P < .001). The calcium mass measurement was more accurate and less variable than the calcium volume measurement. © RSNA, 2002. | - |
dc.language | eng | - |
dc.relation.ispartof | Radiology | - |
dc.subject | Computed tomography (CT), radiation exposure | - |
dc.subject | Coronary vessels, calcification | - |
dc.subject | Coronary vessels, CT | - |
dc.title | Coronary artery calcium measurement with multi-detector row CT: In vitro assessment of effect of radiation dose | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1148/radiol.2253011871 | - |
dc.identifier.pmid | 12461277 | - |
dc.identifier.scopus | eid_2-s2.0-0036891972 | - |
dc.identifier.volume | 225 | - |
dc.identifier.issue | 3 | - |
dc.identifier.spage | 901 | - |
dc.identifier.epage | 906 | - |
dc.identifier.isi | WOS:000179420800039 | - |