Article: Gadolinium-Enhanced Computed Tomography Angiography in Multi-Detector Row Computed Tomography: Initial Observations
Title | Gadolinium-Enhanced Computed Tomography Angiography in Multi-Detector Row Computed Tomography: Initial Observations |
---|---|
Authors | |
Keywords | Aorta Computed tomography Contrast media Gadolinium Helical technology Iodine |
Issue Date | 2004 |
Citation | Academic Radiology, 2004, v. 11, n. 1, p. 61-68 How to Cite? |
Abstract | Rationale and Objectives. The feasibility of using gadolinium contrast medium for computed tomography angiography (CTA) in multi-detector row computed tomography and the effect of contrast medium dilution was investigated. Materials and Methods. Three pigs were each scanned in multiple sessions with injections of non-dilute and dilute contrast medium at a dose of 0.3 mmol/kg body weight. Non-spiral dynamic scanning at a fixed mid-abdominal aortic level and thoracoabdominal CTA were performed. Results. The magnitude of peak aortic enhancement was not significantly different between dilute and non-dilute contrast medium injections (P = .88), but the former showed earlier enhancement (mean of 2.3 seconds sooner, P < .01) than the latter. CT angiography with gadolinium contrast medium showed much lower enhancement than iodine contrast medium, but small vessels were readily identifiable. Conclusion. Gadolinium contrast medium combined with multi-detector row computed tomography may provide clinically useful CTA. Dilution of contrast medium shortens the enhancement time but has little effect on the magnitude. © AUR, 2004. |
Persistent Identifier | http://hdl.handle.net/10722/315940 |
ISSN | 2023 Impact Factor: 3.8 2023 SCImago Journal Rankings: 1.062 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bae, Kyongtae T. | - |
dc.contributor.author | McDermott, Ronan | - |
dc.contributor.author | Gierada, David S. | - |
dc.contributor.author | Heiken, Jay P. | - |
dc.contributor.author | Nolte, Mark A. | - |
dc.contributor.author | Takahashi, Naoki | - |
dc.contributor.author | Hong, Cheng | - |
dc.date.accessioned | 2022-08-24T15:48:40Z | - |
dc.date.available | 2022-08-24T15:48:40Z | - |
dc.date.issued | 2004 | - |
dc.identifier.citation | Academic Radiology, 2004, v. 11, n. 1, p. 61-68 | - |
dc.identifier.issn | 1076-6332 | - |
dc.identifier.uri | http://hdl.handle.net/10722/315940 | - |
dc.description.abstract | Rationale and Objectives. The feasibility of using gadolinium contrast medium for computed tomography angiography (CTA) in multi-detector row computed tomography and the effect of contrast medium dilution was investigated. Materials and Methods. Three pigs were each scanned in multiple sessions with injections of non-dilute and dilute contrast medium at a dose of 0.3 mmol/kg body weight. Non-spiral dynamic scanning at a fixed mid-abdominal aortic level and thoracoabdominal CTA were performed. Results. The magnitude of peak aortic enhancement was not significantly different between dilute and non-dilute contrast medium injections (P = .88), but the former showed earlier enhancement (mean of 2.3 seconds sooner, P < .01) than the latter. CT angiography with gadolinium contrast medium showed much lower enhancement than iodine contrast medium, but small vessels were readily identifiable. Conclusion. Gadolinium contrast medium combined with multi-detector row computed tomography may provide clinically useful CTA. Dilution of contrast medium shortens the enhancement time but has little effect on the magnitude. © AUR, 2004. | - |
dc.language | eng | - |
dc.relation.ispartof | Academic Radiology | - |
dc.subject | Aorta | - |
dc.subject | Computed tomography | - |
dc.subject | Contrast media | - |
dc.subject | Gadolinium | - |
dc.subject | Helical technology | - |
dc.subject | Iodine | - |
dc.title | Gadolinium-Enhanced Computed Tomography Angiography in Multi-Detector Row Computed Tomography: Initial Observations | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/S1076-6332(03)00536-1 | - |
dc.identifier.pmid | 14746403 | - |
dc.identifier.scopus | eid_2-s2.0-0346102679 | - |
dc.identifier.volume | 11 | - |
dc.identifier.issue | 1 | - |
dc.identifier.spage | 61 | - |
dc.identifier.epage | 68 | - |
dc.identifier.isi | WOS:000187721200009 | - |