File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.2214/AJR.06.0372
- Scopus: eid_2-s2.0-33847176611
- PMID: 17312064
- WOS: WOS:000245663300023
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: MDCT of the pancreas: Optimizing scanning delay with a bolus-tracking technique for pancreatic, peripancreatic vascular, and hepatic contrast enhancement
Title | MDCT of the pancreas: Optimizing scanning delay with a bolus-tracking technique for pancreatic, peripancreatic vascular, and hepatic contrast enhancement |
---|---|
Authors | |
Keywords | Contrast media CT technique Liver MDCT Pancreas |
Issue Date | 2007 |
Citation | American Journal of Roentgenology, 2007, v. 188, n. 3, p. 751-756 How to Cite? |
Abstract | OBJECTIVE. The purpose of this study was to determine the optimal MDCT scanning delay for peripancreatic arterial, pancreatic parenchymal, peripancreatic venous, and hepatic parenchymal contrast enhancement with a bolus-tracking technique. SUBJECTS AND METHODS. Three-phase 8-MDCT of the pancreas was performed on 170 patients after administration of 2 mL/kg of 300 mg I/mL contrast medium injected at 4 mL/s to a total dose of 150 mL. Patients were prospectively randomized into three groups with different scanning delays for the three phases (arterial, pancreatic, and venous) after bolus tracking was triggered at 50 H of aortic contrast enhancement: group 1 (5, 20, 45 seconds); group 2 (10, 25, 50 seconds); and group 3 (15, 30, 55 seconds). Mean attenuation values of the abdominal aorta, superior mesenteric artery, pancreatic parenchyma, splenic vein, superior mesenteric vein, portal vein, and hepatic parenchyma were measured. Increases in attenuation values after contrast administration were assessed as change in attenuation value. Qualitative analysis also was performed. RESULTS. Mean contrast enhancement in the aorta (change in attenuation, 321-327 H) and the superior mesenteric artery (change in attenuation, 304-307 H) approached peak enhancement 5-10 seconds after bolus tracking was triggered. Pancreatic parenchyma became most intensely enhanced (change in attenuation, 84-85 H) 15-20 seconds after triggering, and then the enhancement gradually decreased. Enhancement of the splenic vein and portal vein peaked 25 seconds and that of the superior mesenteric vein peaked 30 seconds after triggering. Liver parenchyma reached 52 H 30 seconds after triggering and reached a plateau (change in attenuation, 58-61 H) at a further scanning delay of 45-55 seconds. Qualitative results were in good agreement with quantitative results. CONCLUSION. For the injection protocol used in this study, optimal scanning delay after triggering of bolus tracking at 50 H of aortic contrast enhancement was 5-10 seconds for the peripancreatic arterial phase, 15-20 seconds for the pancreatic parenchymal phase, and 45-55 seconds for the hepatic parenchymal phase. © American Roentgen Ray Society. |
Persistent Identifier | http://hdl.handle.net/10722/315983 |
ISSN | 2023 Impact Factor: 4.7 2023 SCImago Journal Rankings: 1.235 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kondo, Hiroshi | - |
dc.contributor.author | Kanematsu, Masayuki | - |
dc.contributor.author | Goshima, Satoshi | - |
dc.contributor.author | Miyoshi, Toshiharu | - |
dc.contributor.author | Shiratori, Yoshimune | - |
dc.contributor.author | Onozuka, Minoru | - |
dc.contributor.author | Moriyama, Noriyuki | - |
dc.contributor.author | Bae, Kyongtae T. | - |
dc.date.accessioned | 2022-08-24T15:48:50Z | - |
dc.date.available | 2022-08-24T15:48:50Z | - |
dc.date.issued | 2007 | - |
dc.identifier.citation | American Journal of Roentgenology, 2007, v. 188, n. 3, p. 751-756 | - |
dc.identifier.issn | 0361-803X | - |
dc.identifier.uri | http://hdl.handle.net/10722/315983 | - |
dc.description.abstract | OBJECTIVE. The purpose of this study was to determine the optimal MDCT scanning delay for peripancreatic arterial, pancreatic parenchymal, peripancreatic venous, and hepatic parenchymal contrast enhancement with a bolus-tracking technique. SUBJECTS AND METHODS. Three-phase 8-MDCT of the pancreas was performed on 170 patients after administration of 2 mL/kg of 300 mg I/mL contrast medium injected at 4 mL/s to a total dose of 150 mL. Patients were prospectively randomized into three groups with different scanning delays for the three phases (arterial, pancreatic, and venous) after bolus tracking was triggered at 50 H of aortic contrast enhancement: group 1 (5, 20, 45 seconds); group 2 (10, 25, 50 seconds); and group 3 (15, 30, 55 seconds). Mean attenuation values of the abdominal aorta, superior mesenteric artery, pancreatic parenchyma, splenic vein, superior mesenteric vein, portal vein, and hepatic parenchyma were measured. Increases in attenuation values after contrast administration were assessed as change in attenuation value. Qualitative analysis also was performed. RESULTS. Mean contrast enhancement in the aorta (change in attenuation, 321-327 H) and the superior mesenteric artery (change in attenuation, 304-307 H) approached peak enhancement 5-10 seconds after bolus tracking was triggered. Pancreatic parenchyma became most intensely enhanced (change in attenuation, 84-85 H) 15-20 seconds after triggering, and then the enhancement gradually decreased. Enhancement of the splenic vein and portal vein peaked 25 seconds and that of the superior mesenteric vein peaked 30 seconds after triggering. Liver parenchyma reached 52 H 30 seconds after triggering and reached a plateau (change in attenuation, 58-61 H) at a further scanning delay of 45-55 seconds. Qualitative results were in good agreement with quantitative results. CONCLUSION. For the injection protocol used in this study, optimal scanning delay after triggering of bolus tracking at 50 H of aortic contrast enhancement was 5-10 seconds for the peripancreatic arterial phase, 15-20 seconds for the pancreatic parenchymal phase, and 45-55 seconds for the hepatic parenchymal phase. © American Roentgen Ray Society. | - |
dc.language | eng | - |
dc.relation.ispartof | American Journal of Roentgenology | - |
dc.subject | Contrast media | - |
dc.subject | CT technique | - |
dc.subject | Liver | - |
dc.subject | MDCT | - |
dc.subject | Pancreas | - |
dc.title | MDCT of the pancreas: Optimizing scanning delay with a bolus-tracking technique for pancreatic, peripancreatic vascular, and hepatic contrast enhancement | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.2214/AJR.06.0372 | - |
dc.identifier.pmid | 17312064 | - |
dc.identifier.scopus | eid_2-s2.0-33847176611 | - |
dc.identifier.volume | 188 | - |
dc.identifier.issue | 3 | - |
dc.identifier.spage | 751 | - |
dc.identifier.epage | 756 | - |
dc.identifier.isi | WOS:000245663300023 | - |