File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Automated matching of pulmonary nodules: Evaluation in serial screening chest CT

TitleAutomated matching of pulmonary nodules: Evaluation in serial screening chest CT
Authors
KeywordsChest CT
Computer-aided diagnosis
Lung cancer screening
Pulmonary nodules
Issue Date2009
Citation
American Journal of Roentgenology, 2009, v. 192, n. 3, p. 624-628 How to Cite?
AbstractOBJECTIVE. The purpose of our study was to evaluate the performance of a computer-aided program that performs automated matching of pulmonary nodules imaged in three serial screening chest MDCT studies. MATE RIALS AND METHODS. Forty subjects with pulmonary nodules depicted in three annual (T0, T1, T2) low-dose MDCT screening studies for lung cancer were selected from the National Lung Screening Trial database at a single institution. All CT images were reevaluated by two radiologists in consensus. One hundred forty-three nodules were identified and characterized by type (solid parenchymal, juxtavascular, juxtapleural, and ground-glass opacity) and size (≤ 4 mm, 4-6 mm, 6-8 mm, and > 8 mm). Using an automated program, nodules at TO were matched to nodules at T1, and the same nodules at T1 were matched to nodules at T2. Associations between nodule matching rate (i.e., number of nodules matched by the program divided by the number of nodules determined to match by radiologists) and nodule type or size were analyzed. RESULTS. The combined matching rate of the nodules was 92.7% (TO vs T1, 91.6%; T1 vs T2, 93.7%). By nodule type, the matching rate was 94.6% (parenchymal), 98.4% (juxtavascular), 85.8% (juxtapleural), and 100% (ground-glass opacity), with the rate significantly lower for juxtapleural nodules (p < 0.01). Matching rates were not significantly influenced by nodule size (p = 0.67). CONCLUSION. The automated matching rate for pulmonary nodules in screening MDCT scans was high (92.7%) and was not affected by the nodule size but was slightly lower with nodules at juxtapleural locations. © American Roentgen Ray Society.
Persistent Identifierhttp://hdl.handle.net/10722/316015
ISSN
2021 Impact Factor: 6.582
2020 SCImago Journal Rankings: 1.294
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorTao, Cheng-
dc.contributor.authorGierada, David S.-
dc.contributor.authorZhu, Fang-
dc.contributor.authorPilgram, Thomas K.-
dc.contributor.authorWang, Jin Hong-
dc.contributor.authorBae, Kyongtae T.-
dc.date.accessioned2022-08-24T15:48:57Z-
dc.date.available2022-08-24T15:48:57Z-
dc.date.issued2009-
dc.identifier.citationAmerican Journal of Roentgenology, 2009, v. 192, n. 3, p. 624-628-
dc.identifier.issn0361-803X-
dc.identifier.urihttp://hdl.handle.net/10722/316015-
dc.description.abstractOBJECTIVE. The purpose of our study was to evaluate the performance of a computer-aided program that performs automated matching of pulmonary nodules imaged in three serial screening chest MDCT studies. MATE RIALS AND METHODS. Forty subjects with pulmonary nodules depicted in three annual (T0, T1, T2) low-dose MDCT screening studies for lung cancer were selected from the National Lung Screening Trial database at a single institution. All CT images were reevaluated by two radiologists in consensus. One hundred forty-three nodules were identified and characterized by type (solid parenchymal, juxtavascular, juxtapleural, and ground-glass opacity) and size (≤ 4 mm, 4-6 mm, 6-8 mm, and > 8 mm). Using an automated program, nodules at TO were matched to nodules at T1, and the same nodules at T1 were matched to nodules at T2. Associations between nodule matching rate (i.e., number of nodules matched by the program divided by the number of nodules determined to match by radiologists) and nodule type or size were analyzed. RESULTS. The combined matching rate of the nodules was 92.7% (TO vs T1, 91.6%; T1 vs T2, 93.7%). By nodule type, the matching rate was 94.6% (parenchymal), 98.4% (juxtavascular), 85.8% (juxtapleural), and 100% (ground-glass opacity), with the rate significantly lower for juxtapleural nodules (p < 0.01). Matching rates were not significantly influenced by nodule size (p = 0.67). CONCLUSION. The automated matching rate for pulmonary nodules in screening MDCT scans was high (92.7%) and was not affected by the nodule size but was slightly lower with nodules at juxtapleural locations. © American Roentgen Ray Society.-
dc.languageeng-
dc.relation.ispartofAmerican Journal of Roentgenology-
dc.subjectChest CT-
dc.subjectComputer-aided diagnosis-
dc.subjectLung cancer screening-
dc.subjectPulmonary nodules-
dc.titleAutomated matching of pulmonary nodules: Evaluation in serial screening chest CT-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.2214/AJR.08.1307-
dc.identifier.pmid19234256-
dc.identifier.scopuseid_2-s2.0-63049087022-
dc.identifier.volume192-
dc.identifier.issue3-
dc.identifier.spage624-
dc.identifier.epage628-
dc.identifier.isiWOS:000264005700013-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats