Article: Volumetric measurement of renal cysts and parenchyma using MRI: Phantoms and patients with polycystic kidney disease
Title | Volumetric measurement of renal cysts and parenchyma using MRI: Phantoms and patients with polycystic kidney disease |
---|---|
Authors | |
Keywords | Kidneys, diseases Kidneys, polycystic Magnetic resonance imaging Parenchyma, renal |
Issue Date | 2000 |
Citation | Journal of Computer Assisted Tomography, 2000, v. 24, n. 4, p. 614-619 How to Cite? |
Abstract | We have developed an MR method to measure the volumes of renal cysts and parenchyma in patients with polycystic kidney disease. Phantoms were designed to simulate polycystic kidneys. Four patients were recruited. MR scans were performed on the phantoms and patients. A stereology technique was, applied for image segmentation and volume measurement. Volumetric measurement of renal cysts and parenchyma was accurate in phantom studies and reliable in both phantom and patient studies in these limited examples. |
Persistent Identifier | http://hdl.handle.net/10722/316160 |
ISSN | 2023 Impact Factor: 1.0 2023 SCImago Journal Rankings: 0.415 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bae, Kyongtae T. | - |
dc.contributor.author | Commean, Paul K. | - |
dc.contributor.author | Lee, Jeongrim | - |
dc.date.accessioned | 2022-08-24T15:49:27Z | - |
dc.date.available | 2022-08-24T15:49:27Z | - |
dc.date.issued | 2000 | - |
dc.identifier.citation | Journal of Computer Assisted Tomography, 2000, v. 24, n. 4, p. 614-619 | - |
dc.identifier.issn | 0363-8715 | - |
dc.identifier.uri | http://hdl.handle.net/10722/316160 | - |
dc.description.abstract | We have developed an MR method to measure the volumes of renal cysts and parenchyma in patients with polycystic kidney disease. Phantoms were designed to simulate polycystic kidneys. Four patients were recruited. MR scans were performed on the phantoms and patients. A stereology technique was, applied for image segmentation and volume measurement. Volumetric measurement of renal cysts and parenchyma was accurate in phantom studies and reliable in both phantom and patient studies in these limited examples. | - |
dc.language | eng | - |
dc.relation.ispartof | Journal of Computer Assisted Tomography | - |
dc.subject | Kidneys, diseases | - |
dc.subject | Kidneys, polycystic | - |
dc.subject | Magnetic resonance imaging | - |
dc.subject | Parenchyma, renal | - |
dc.title | Volumetric measurement of renal cysts and parenchyma using MRI: Phantoms and patients with polycystic kidney disease | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1097/00004728-200007000-00019 | - |
dc.identifier.pmid | 10966197 | - |
dc.identifier.scopus | eid_2-s2.0-0034468489 | - |
dc.identifier.volume | 24 | - |
dc.identifier.issue | 4 | - |
dc.identifier.spage | 614 | - |
dc.identifier.epage | 619 | - |
dc.identifier.isi | WOS:000088752000019 | - |