Article: Development and performance evaluation of a chiller plant predictive operational control strategy by artificial intelligence

TitleDevelopment and performance evaluation of a chiller plant predictive operational control strategy by artificial intelligence
Authors
Issue Date2022
Citation
Energy and Buildings, 2022, v. 262, p. 112017 How to Cite?
AbstractTraditionally, chiller plants are controlled and monitored by a predetermined control strategy to ensure appropriate operation based on the designed system configuration. With the use of new technology of variable speed drive (VSD) for compressors, smart control strategies could be leveraged to enhance the system efficiency in lieu of traditional control strategies. For example, using orderly and straightforward switching procedures without considering various factors in switching the units, including the high-efficiency partial load range benefitted from the VSD, the actual performance of the units as a whole and the variable chilled water flow rate, result in the chiller plant not operating at maximum performance and efficiency. To address these issues, a hybrid predictive operational chiller plant control strategy is proposed to optimize the performance of the chiller plant. Artificial intelligence is employed as the data mining algorithm, with big data analysis based on the actual acquired voluminous operation data by fully considering the characteristics of chiller plants without additional installation of large-sized and high-priced equipment. Artificial neural network (ANN) was employed in the control strategy to predict the future outdoor temperature, building cooling load demand and the corresponding power consumption of the chiller plants. At the same time, particle swarm optimization (PSO) was applied to search for the optimized setpoints, e.g., chilled water supply temperature, operating sequence, chilled water flow rate, for the chiller plants. The developed control strategy has been launched in a chiller plant with a cooling capacity of 7,700 kW installed in a hospital in Hong Kong. The system coefficient of performance (COP) and overall energy consumption of the chiller plants were enhanced by about 8.6% and reduced by about 7.9%, respectively, compared with the traditional control strategy. This real-time, continuous, automatic optimization control strategy can determine the most efficient combination of operating parameters of a chiller plant with different control settings. This ensures that the chiller plant operates in its most efficient mode year-round under various operational conditions.
Persistent Identifierhttp://hdl.handle.net/10722/320839
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorChan, KC-
dc.contributor.authorWong, VTT-
dc.contributor.authorYow, AKF-
dc.contributor.authorYuen, PL-
dc.contributor.authorChao, CYH-
dc.date.accessioned2022-11-01T04:42:13Z-
dc.date.available2022-11-01T04:42:13Z-
dc.date.issued2022-
dc.identifier.citationEnergy and Buildings, 2022, v. 262, p. 112017-
dc.identifier.urihttp://hdl.handle.net/10722/320839-
dc.description.abstractTraditionally, chiller plants are controlled and monitored by a predetermined control strategy to ensure appropriate operation based on the designed system configuration. With the use of new technology of variable speed drive (VSD) for compressors, smart control strategies could be leveraged to enhance the system efficiency in lieu of traditional control strategies. For example, using orderly and straightforward switching procedures without considering various factors in switching the units, including the high-efficiency partial load range benefitted from the VSD, the actual performance of the units as a whole and the variable chilled water flow rate, result in the chiller plant not operating at maximum performance and efficiency. To address these issues, a hybrid predictive operational chiller plant control strategy is proposed to optimize the performance of the chiller plant. Artificial intelligence is employed as the data mining algorithm, with big data analysis based on the actual acquired voluminous operation data by fully considering the characteristics of chiller plants without additional installation of large-sized and high-priced equipment. Artificial neural network (ANN) was employed in the control strategy to predict the future outdoor temperature, building cooling load demand and the corresponding power consumption of the chiller plants. At the same time, particle swarm optimization (PSO) was applied to search for the optimized setpoints, e.g., chilled water supply temperature, operating sequence, chilled water flow rate, for the chiller plants. The developed control strategy has been launched in a chiller plant with a cooling capacity of 7,700 kW installed in a hospital in Hong Kong. The system coefficient of performance (COP) and overall energy consumption of the chiller plants were enhanced by about 8.6% and reduced by about 7.9%, respectively, compared with the traditional control strategy. This real-time, continuous, automatic optimization control strategy can determine the most efficient combination of operating parameters of a chiller plant with different control settings. This ensures that the chiller plant operates in its most efficient mode year-round under various operational conditions.-
dc.languageeng-
dc.relation.ispartofEnergy and Buildings-
dc.titleDevelopment and performance evaluation of a chiller plant predictive operational control strategy by artificial intelligence-
dc.typeArticle-
dc.identifier.emailChan, KC: mekcchan@hku.hk-
dc.identifier.doi10.1016/j.enbuild.2022.112017-
dc.identifier.hkuros340931-
dc.identifier.volume262-
dc.identifier.spage112017-
dc.identifier.epage112017-
dc.identifier.isiWOS:000803783000009-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats