File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/j.rse.2009.03.009
- Scopus: eid_2-s2.0-67349246745
- WOS: WOS:000266736900019
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Evaluation of ASTER and MODIS land surface temperature and emissivity products using long-term surface longwave radiation observations at SURFRAD sites
Title | Evaluation of ASTER and MODIS land surface temperature and emissivity products using long-term surface longwave radiation observations at SURFRAD sites |
---|---|
Authors | |
Keywords | ASTER Emissivity Land surface temperature MODIS Surface radiation budget |
Issue Date | 2009 |
Citation | Remote Sensing of Environment, 2009, v. 113, n. 7, p. 1556-1565 How to Cite? |
Abstract | Land surface temperature (LST) and emissivity are key parameters in estimating the land surface radiation budget, a major controlling factor of global climate and environmental change. In this study, Terra Advanced Spaceborne Thermal Emission Reflection Radiometer (ASTER) and Aqua MODerate resolution Imaging Spectroradiometer (MODIS) Collection 5 LST and emissivity products are evaluated using long-term ground-based longwave radiation observations collected at six Surface Radiation Budget Network (SURFRAD) sites from 2000 to 2007. LSTs at a spatial resolution of 90 m from 197 ASTER images during 2000-2007 are directly compared to ground observations at the six SURFRAD sites. For nighttime data, ASTER LST has an average bias of 0.1 °C and the average bias is 0.3 °C during daytime. Aqua MODIS LST at 1 km resolution during nighttime retrieved from a split-window algorithm is evaluated from 2002 to 2007. MODIS LST has an average bias of - 0.2 °C. LST heterogeneity (defined as the Standard Deviation, STD, of ASTER LSTs in 1 × 1 km2 region, 11 × 11 pixel in total) and instrument calibration error of pyrgeometer are key factors impacting the ASTER and MODIS LST evaluation using ground-based radiation measurements. The heterogeneity of nighttime ASTER LST is 1.2 °C, which accounts for 71% of the STD of the comparison, while the heterogeneity of the daytime LST is 2.4 °C, which accounts for 60% of the STD. Collection 5 broadband emissivity is 0.01 larger than that of MODIS Collection 4 products and ASTER emissivity. It is essential to filter out the abnormal low values of ASTER daily emissivity data in summer time before its application. © 2009 Elsevier Inc. All rights reserved. |
Persistent Identifier | http://hdl.handle.net/10722/321955 |
ISSN | 2023 Impact Factor: 11.1 2023 SCImago Journal Rankings: 4.310 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wang, Kaicun | - |
dc.contributor.author | Liang, Shunlin | - |
dc.date.accessioned | 2022-11-03T02:22:36Z | - |
dc.date.available | 2022-11-03T02:22:36Z | - |
dc.date.issued | 2009 | - |
dc.identifier.citation | Remote Sensing of Environment, 2009, v. 113, n. 7, p. 1556-1565 | - |
dc.identifier.issn | 0034-4257 | - |
dc.identifier.uri | http://hdl.handle.net/10722/321955 | - |
dc.description.abstract | Land surface temperature (LST) and emissivity are key parameters in estimating the land surface radiation budget, a major controlling factor of global climate and environmental change. In this study, Terra Advanced Spaceborne Thermal Emission Reflection Radiometer (ASTER) and Aqua MODerate resolution Imaging Spectroradiometer (MODIS) Collection 5 LST and emissivity products are evaluated using long-term ground-based longwave radiation observations collected at six Surface Radiation Budget Network (SURFRAD) sites from 2000 to 2007. LSTs at a spatial resolution of 90 m from 197 ASTER images during 2000-2007 are directly compared to ground observations at the six SURFRAD sites. For nighttime data, ASTER LST has an average bias of 0.1 °C and the average bias is 0.3 °C during daytime. Aqua MODIS LST at 1 km resolution during nighttime retrieved from a split-window algorithm is evaluated from 2002 to 2007. MODIS LST has an average bias of - 0.2 °C. LST heterogeneity (defined as the Standard Deviation, STD, of ASTER LSTs in 1 × 1 km2 region, 11 × 11 pixel in total) and instrument calibration error of pyrgeometer are key factors impacting the ASTER and MODIS LST evaluation using ground-based radiation measurements. The heterogeneity of nighttime ASTER LST is 1.2 °C, which accounts for 71% of the STD of the comparison, while the heterogeneity of the daytime LST is 2.4 °C, which accounts for 60% of the STD. Collection 5 broadband emissivity is 0.01 larger than that of MODIS Collection 4 products and ASTER emissivity. It is essential to filter out the abnormal low values of ASTER daily emissivity data in summer time before its application. © 2009 Elsevier Inc. All rights reserved. | - |
dc.language | eng | - |
dc.relation.ispartof | Remote Sensing of Environment | - |
dc.subject | ASTER | - |
dc.subject | Emissivity | - |
dc.subject | Land surface temperature | - |
dc.subject | MODIS | - |
dc.subject | Surface radiation budget | - |
dc.title | Evaluation of ASTER and MODIS land surface temperature and emissivity products using long-term surface longwave radiation observations at SURFRAD sites | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/j.rse.2009.03.009 | - |
dc.identifier.scopus | eid_2-s2.0-67349246745 | - |
dc.identifier.volume | 113 | - |
dc.identifier.issue | 7 | - |
dc.identifier.spage | 1556 | - |
dc.identifier.epage | 1565 | - |
dc.identifier.isi | WOS:000266736900019 | - |