Article: Dose escalation of tamoxifen in patients with low endoxifen level: Evidence for therapeutic drug monitoring - The TADE study

TitleDose escalation of tamoxifen in patients with low endoxifen level: Evidence for therapeutic drug monitoring - The TADE study
Authors
Issue Date2016
Citation
Clinical Cancer Research, 2016, v. 22, n. 13, p. 3164-3171 How to Cite?
AbstractPurpose: Endoxifen is the major mediator of tamoxifen effect and endoxifen levels <15 nmol/L may be associated with increased risk of breast cancer recurrence. We increased tamoxifen dose in breast cancer patients with low endoxifen levels and assessed the influence of various parameters on reaching 15 nmol/L and 30 nmol/L endoxifen levels. Experimental Design: Tamoxifen dose was increased in those with endoxifen levels below 30 nmol/L. Toxicity, including hot flash score, was measured. CYP2D6 metabolizer status was classified as ultra-rapid (UM), extensive (EM), intermediate (IM), or poor (PM) based genotype of somatic DNA. Results: Dosage was escalated in 68 of 122 participants. On 20 mg tamoxifen, 24% had endoxifen levels below 15 nmol/L and this reduced to 6% following dose escalation. In over 50% of cases, there was no identified cause for low endoxifen. Low baseline endoxifen level, and not CYP2D6 metabolizer status, independently predicted reaching threshold targets for both the 15 nmol/L and 30 nmol/L targets (P = 0.04 and 0.003 respectively). The 15 nmol/L target was reached in all UM/EM and IM patients, 63% of PM patients, and 58% of those with baseline endoxifen of <10 nmol/L. There was no correlation between hot flash score and genotype or any tamoxifen metabolite level including endoxifen (R = 0.07). Conclusions: Low endoxifen on standard dose tamoxifen was the only independent predictor of failure to achieve potentially therapeutic levels. Trials examining tamoxifen dose escalation and breast cancer outcome should be guided by endoxifen levels alone, without reference to CYP2D6 genotype or presence of hot flashes.
Persistent Identifierhttp://hdl.handle.net/10722/326468
ISSN
2023 Impact Factor: 10.0
2023 SCImago Journal Rankings: 4.623
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorFox, Peter-
dc.contributor.authorBalleine, Rosemary L.-
dc.contributor.authorLee, Clara-
dc.contributor.authorGao, Bo-
dc.contributor.authorBalakrishnar, Bavanthi-
dc.contributor.authorMenzies, Alexander M.-
dc.contributor.authorYeap, Shang Heng-
dc.contributor.authorAli, Sayed Sahanawaz-
dc.contributor.authorGebski, Val-
dc.contributor.authorProvan, Pamela-
dc.contributor.authorCoulter, Sally-
dc.contributor.authorLiddle, Christopher-
dc.contributor.authorHui, Rina-
dc.contributor.authorKefford, Richard-
dc.contributor.authorLynch, Jodi-
dc.contributor.authorWong, Mark-
dc.contributor.authorWilcken, Nicholas-
dc.contributor.authorGurney, Howard-
dc.date.accessioned2023-03-10T02:19:30Z-
dc.date.available2023-03-10T02:19:30Z-
dc.date.issued2016-
dc.identifier.citationClinical Cancer Research, 2016, v. 22, n. 13, p. 3164-3171-
dc.identifier.issn1078-0432-
dc.identifier.urihttp://hdl.handle.net/10722/326468-
dc.description.abstractPurpose: Endoxifen is the major mediator of tamoxifen effect and endoxifen levels <15 nmol/L may be associated with increased risk of breast cancer recurrence. We increased tamoxifen dose in breast cancer patients with low endoxifen levels and assessed the influence of various parameters on reaching 15 nmol/L and 30 nmol/L endoxifen levels. Experimental Design: Tamoxifen dose was increased in those with endoxifen levels below 30 nmol/L. Toxicity, including hot flash score, was measured. CYP2D6 metabolizer status was classified as ultra-rapid (UM), extensive (EM), intermediate (IM), or poor (PM) based genotype of somatic DNA. Results: Dosage was escalated in 68 of 122 participants. On 20 mg tamoxifen, 24% had endoxifen levels below 15 nmol/L and this reduced to 6% following dose escalation. In over 50% of cases, there was no identified cause for low endoxifen. Low baseline endoxifen level, and not CYP2D6 metabolizer status, independently predicted reaching threshold targets for both the 15 nmol/L and 30 nmol/L targets (P = 0.04 and 0.003 respectively). The 15 nmol/L target was reached in all UM/EM and IM patients, 63% of PM patients, and 58% of those with baseline endoxifen of <10 nmol/L. There was no correlation between hot flash score and genotype or any tamoxifen metabolite level including endoxifen (R = 0.07). Conclusions: Low endoxifen on standard dose tamoxifen was the only independent predictor of failure to achieve potentially therapeutic levels. Trials examining tamoxifen dose escalation and breast cancer outcome should be guided by endoxifen levels alone, without reference to CYP2D6 genotype or presence of hot flashes.-
dc.languageeng-
dc.relation.ispartofClinical Cancer Research-
dc.titleDose escalation of tamoxifen in patients with low endoxifen level: Evidence for therapeutic drug monitoring - The TADE study-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1158/1078-0432.CCR-15-1470-
dc.identifier.pmid26847054-