File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Research and simulation on characteristic of hydraulic power source under motor rotor broken bar fault

TitleResearch and simulation on characteristic of hydraulic power source under motor rotor broken bar fault
Authors
KeywordsInduction motor
Power source characteristic
Rotor broken bar
Simulation
Issue Date2012
Citation
Zhongguo Jixie Gongcheng/China Mechanical Engineering, 2012, v. 23, n. 17, p. 2088-2092 How to Cite?
AbstractThe pulsations of electromagnetic torque, rotational speed and power of the motor caused by rotor broken bar fault were analyzed herein. By means of multi-loop method, a mathematical model of hydraulic power source under rotor broken-bar fault was established. The mechanical parameters, electrical parameters and liquid parameters were simulated. The results show that the input and output parameters of hydraulic power source have different degree pulsation. That due to the edge-frequency components of stator current is coupled to the rotor system. The pulse degree and frequency increase with the increasing degree of fault and load, thus the stability operation of hydraulic power source is influenced. Another conclusion points out the efficiency of hydraulic power source is decreased during the fault.
Persistent Identifierhttp://hdl.handle.net/10722/326915
ISSN
2020 SCImago Journal Rankings: 0.212

 

DC FieldValueLanguage
dc.contributor.authorChen, Jiangcheng-
dc.contributor.authorGu, Lichen-
dc.contributor.authorLiu, Peijin-
dc.date.accessioned2023-03-31T05:27:27Z-
dc.date.available2023-03-31T05:27:27Z-
dc.date.issued2012-
dc.identifier.citationZhongguo Jixie Gongcheng/China Mechanical Engineering, 2012, v. 23, n. 17, p. 2088-2092-
dc.identifier.issn1004-132X-
dc.identifier.urihttp://hdl.handle.net/10722/326915-
dc.description.abstractThe pulsations of electromagnetic torque, rotational speed and power of the motor caused by rotor broken bar fault were analyzed herein. By means of multi-loop method, a mathematical model of hydraulic power source under rotor broken-bar fault was established. The mechanical parameters, electrical parameters and liquid parameters were simulated. The results show that the input and output parameters of hydraulic power source have different degree pulsation. That due to the edge-frequency components of stator current is coupled to the rotor system. The pulse degree and frequency increase with the increasing degree of fault and load, thus the stability operation of hydraulic power source is influenced. Another conclusion points out the efficiency of hydraulic power source is decreased during the fault.-
dc.languageeng-
dc.relation.ispartofZhongguo Jixie Gongcheng/China Mechanical Engineering-
dc.subjectInduction motor-
dc.subjectPower source characteristic-
dc.subjectRotor broken bar-
dc.subjectSimulation-
dc.titleResearch and simulation on characteristic of hydraulic power source under motor rotor broken bar fault-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.3969/j.issn.1004-132X.2012.17.015-
dc.identifier.scopuseid_2-s2.0-84867962296-
dc.identifier.volume23-
dc.identifier.issue17-
dc.identifier.spage2088-
dc.identifier.epage2092-