File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/j.brainres.2018.05.018
- Scopus: eid_2-s2.0-85047296765
- PMID: 29777674
- WOS: WOS:000435624300015
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: An approach for brain-controlled prostheses based on Scene Graph Steady-State Visual Evoked Potentials
Title | An approach for brain-controlled prostheses based on Scene Graph Steady-State Visual Evoked Potentials |
---|---|
Authors | |
Keywords | Brain-Computer Interface (BCI) Brain-controlled prostheses Modeling Scene Graph Steady-State Visual Evoked Potentials (SG-SSVEP) |
Issue Date | 2018 |
Citation | Brain Research, 2018, v. 1692, p. 142-153 How to Cite? |
Abstract | Brain control technology can restore communication between the brain and a prosthesis, and choosing a Brain-Computer Interface (BCI) paradigm to evoke electroencephalogram (EEG) signals is an essential step for developing this technology. In this paper, the Scene Graph paradigm used for controlling prostheses was proposed; this paradigm is based on Steady-State Visual Evoked Potentials (SSVEPs) regarding the Scene Graph of a subject's intention. A mathematic model was built to predict SSVEPs evoked by the proposed paradigm and a sinusoidal stimulation method was used to present the Scene Graph stimulus to elicit SSVEPs from subjects. Then, a 2-degree of freedom (2-DOF) brain-controlled prosthesis system was constructed to validate the performance of the Scene Graph-SSVEP (SG-SSVEP)-based BCI. The classification of SG-SSVEPs was detected via the Canonical Correlation Analysis (CCA) approach. To assess the efficiency of proposed BCI system, the performances of traditional SSVEP-BCI system were compared. Experimental results from six subjects suggested that the proposed system effectively enhanced the SSVEP responses, decreased the degradation of SSVEP strength and reduced the visual fatigue in comparison with the traditional SSVEP-BCI system. The average signal to noise ratio (SNR) of SG-SSVEP was 6.31 ± 2.64 dB, versus 3.38 ± 0.78 dB of traditional-SSVEP. In addition, the proposed system achieved good performances in prosthesis control. The average accuracy was 94.58% ± 7.05%, and the corresponding high information transfer rate (IRT) was 19.55 ± 3.07 bit/min. The experimental results revealed that the SG-SSVEP based BCI system achieves the good performance and improved the stability relative to the conventional approach. |
Persistent Identifier | http://hdl.handle.net/10722/327191 |
ISSN | 2023 Impact Factor: 2.7 2023 SCImago Journal Rankings: 0.832 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Li, Rui | - |
dc.contributor.author | Zhang, Xiaodong | - |
dc.contributor.author | Li, Hanzhe | - |
dc.contributor.author | Zhang, Liming | - |
dc.contributor.author | Lu, Zhufeng | - |
dc.contributor.author | Chen, Jiangcheng | - |
dc.date.accessioned | 2023-03-31T05:29:36Z | - |
dc.date.available | 2023-03-31T05:29:36Z | - |
dc.date.issued | 2018 | - |
dc.identifier.citation | Brain Research, 2018, v. 1692, p. 142-153 | - |
dc.identifier.issn | 0006-8993 | - |
dc.identifier.uri | http://hdl.handle.net/10722/327191 | - |
dc.description.abstract | Brain control technology can restore communication between the brain and a prosthesis, and choosing a Brain-Computer Interface (BCI) paradigm to evoke electroencephalogram (EEG) signals is an essential step for developing this technology. In this paper, the Scene Graph paradigm used for controlling prostheses was proposed; this paradigm is based on Steady-State Visual Evoked Potentials (SSVEPs) regarding the Scene Graph of a subject's intention. A mathematic model was built to predict SSVEPs evoked by the proposed paradigm and a sinusoidal stimulation method was used to present the Scene Graph stimulus to elicit SSVEPs from subjects. Then, a 2-degree of freedom (2-DOF) brain-controlled prosthesis system was constructed to validate the performance of the Scene Graph-SSVEP (SG-SSVEP)-based BCI. The classification of SG-SSVEPs was detected via the Canonical Correlation Analysis (CCA) approach. To assess the efficiency of proposed BCI system, the performances of traditional SSVEP-BCI system were compared. Experimental results from six subjects suggested that the proposed system effectively enhanced the SSVEP responses, decreased the degradation of SSVEP strength and reduced the visual fatigue in comparison with the traditional SSVEP-BCI system. The average signal to noise ratio (SNR) of SG-SSVEP was 6.31 ± 2.64 dB, versus 3.38 ± 0.78 dB of traditional-SSVEP. In addition, the proposed system achieved good performances in prosthesis control. The average accuracy was 94.58% ± 7.05%, and the corresponding high information transfer rate (IRT) was 19.55 ± 3.07 bit/min. The experimental results revealed that the SG-SSVEP based BCI system achieves the good performance and improved the stability relative to the conventional approach. | - |
dc.language | eng | - |
dc.relation.ispartof | Brain Research | - |
dc.subject | Brain-Computer Interface (BCI) | - |
dc.subject | Brain-controlled prostheses | - |
dc.subject | Modeling | - |
dc.subject | Scene Graph Steady-State Visual Evoked Potentials (SG-SSVEP) | - |
dc.title | An approach for brain-controlled prostheses based on Scene Graph Steady-State Visual Evoked Potentials | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/j.brainres.2018.05.018 | - |
dc.identifier.pmid | 29777674 | - |
dc.identifier.scopus | eid_2-s2.0-85047296765 | - |
dc.identifier.volume | 1692 | - |
dc.identifier.spage | 142 | - |
dc.identifier.epage | 153 | - |
dc.identifier.eissn | 1872-6240 | - |
dc.identifier.isi | WOS:000435624300015 | - |