File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1088/1748-0221/15/12/C12004
- Scopus: eid_2-s2.0-85098257837
- WOS: WOS:000608267500003
Supplementary
- Citations:
- Appears in Collections:
Conference Paper: Linearity and rate capability measurements of RPC with semi-insulating crystalline electrodes operating in avalanche mode
Title | Linearity and rate capability measurements of RPC with semi-insulating crystalline electrodes operating in avalanche mode |
---|---|
Authors | |
Keywords | Detector design and construction technologies and materials Gaseous detectors Materials for gaseous detectors Resistive-plate chambers |
Issue Date | 2020 |
Citation | Journal of Instrumentation, 2020, v. 15, n. 12, article no. C12004 How to Cite? |
Abstract | The intrinsic rate capability and the ageing properties of the Resistive Plate Chambers are closely related to the electrodes material and to the front-end electronics threshold. The development of a low noise pre-amplifier led us to improve the intrinsic rate capability of High Pressure Laminate (bakelite) RPCs up to ∼10 kHz/cm2, nevertheless the effective rate is significantly limited by electrodes ageing. To further improve the effective rate capability new materials are investigated. A Resistive Plate Chamber with crystalline semi-insulating Gallium Arsenide electrodes has been characterized with high energy electrons beam at the Beam Test Facility (BTF), (INFN National Laboratory of Frascati, Italy). The response of the Resistive Plate Chamber to multiple bunched electrons was measured operating the detector in avalanche mode. The intrinsic rate capability has been also measured operating the detector in a uniform high energy gamma radiation field at the GIF++ facility (EHN1 of SPS, CERN). |
Persistent Identifier | http://hdl.handle.net/10722/327565 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Rocchi, A. | - |
dc.contributor.author | Cardarelli, R. | - |
dc.contributor.author | Liberti, B. | - |
dc.contributor.author | Aielli, G. | - |
dc.contributor.author | Camelia, E. Alunno | - |
dc.contributor.author | Camarri, P. | - |
dc.contributor.author | Caltabiano, A. | - |
dc.contributor.author | Cirillo, M. | - |
dc.contributor.author | Di Ciaccio, A. | - |
dc.contributor.author | Di Stante, L. | - |
dc.contributor.author | Lucci, M. | - |
dc.contributor.author | Pastori, E. | - |
dc.contributor.author | Pizzimento, L. | - |
dc.contributor.author | Proto, G. | - |
dc.contributor.author | Tusi, E. | - |
dc.contributor.author | Santonico, R. | - |
dc.date.accessioned | 2023-04-03T12:16:13Z | - |
dc.date.available | 2023-04-03T12:16:13Z | - |
dc.date.issued | 2020 | - |
dc.identifier.citation | Journal of Instrumentation, 2020, v. 15, n. 12, article no. C12004 | - |
dc.identifier.uri | http://hdl.handle.net/10722/327565 | - |
dc.description.abstract | The intrinsic rate capability and the ageing properties of the Resistive Plate Chambers are closely related to the electrodes material and to the front-end electronics threshold. The development of a low noise pre-amplifier led us to improve the intrinsic rate capability of High Pressure Laminate (bakelite) RPCs up to ∼10 kHz/cm2, nevertheless the effective rate is significantly limited by electrodes ageing. To further improve the effective rate capability new materials are investigated. A Resistive Plate Chamber with crystalline semi-insulating Gallium Arsenide electrodes has been characterized with high energy electrons beam at the Beam Test Facility (BTF), (INFN National Laboratory of Frascati, Italy). The response of the Resistive Plate Chamber to multiple bunched electrons was measured operating the detector in avalanche mode. The intrinsic rate capability has been also measured operating the detector in a uniform high energy gamma radiation field at the GIF++ facility (EHN1 of SPS, CERN). | - |
dc.language | eng | - |
dc.relation.ispartof | Journal of Instrumentation | - |
dc.subject | Detector design and construction technologies and materials | - |
dc.subject | Gaseous detectors | - |
dc.subject | Materials for gaseous detectors | - |
dc.subject | Resistive-plate chambers | - |
dc.title | Linearity and rate capability measurements of RPC with semi-insulating crystalline electrodes operating in avalanche mode | - |
dc.type | Conference_Paper | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1088/1748-0221/15/12/C12004 | - |
dc.identifier.scopus | eid_2-s2.0-85098257837 | - |
dc.identifier.volume | 15 | - |
dc.identifier.issue | 12 | - |
dc.identifier.spage | article no. C12004 | - |
dc.identifier.epage | article no. C12004 | - |
dc.identifier.eissn | 1748-0221 | - |
dc.identifier.isi | WOS:000608267500003 | - |