File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1088/1748-0221/14/12/C12005
- Scopus: eid_2-s2.0-85080041550
- WOS: WOS:000510148700005
Supplementary
- Citations:
- Appears in Collections:
Conference Paper: RPC detectors with semiconductive electrodes: efficiency and time resolution measurements
Title | RPC detectors with semiconductive electrodes: efficiency and time resolution measurements |
---|---|
Authors | |
Keywords | Gaseous detectors Resistive-plate chambers Solid state detectors |
Issue Date | 2019 |
Citation | Journal of Instrumentation, 2019, v. 14, n. 12, article no. C12005 How to Cite? |
Abstract | A new particle detector with sub-nanosecond time resolution capable of working in high-rate environment (rate capability of the order of MHz cm2) is under developmnet. Semi-conductive electrodes with resistivity ρ up to 108 Ωcm have been used to improve the RPC [1,2] rate capability. In this paper efficiency and time resolution of three different detector structures are presented. |
Persistent Identifier | http://hdl.handle.net/10722/327587 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Rocchi, A. | - |
dc.contributor.author | Cardarelli, R. | - |
dc.contributor.author | Aielli, G. | - |
dc.contributor.author | Camelia, E. Alunno | - |
dc.contributor.author | Bruno, S. | - |
dc.contributor.author | Caltabiano, A. | - |
dc.contributor.author | Camarri, P. | - |
dc.contributor.author | Di Ciaccio, A. | - |
dc.contributor.author | Liberti, B. | - |
dc.contributor.author | Massa, L. | - |
dc.contributor.author | Pizzimento, L. | - |
dc.date.accessioned | 2023-04-03T12:27:51Z | - |
dc.date.available | 2023-04-03T12:27:51Z | - |
dc.date.issued | 2019 | - |
dc.identifier.citation | Journal of Instrumentation, 2019, v. 14, n. 12, article no. C12005 | - |
dc.identifier.uri | http://hdl.handle.net/10722/327587 | - |
dc.description.abstract | A new particle detector with sub-nanosecond time resolution capable of working in high-rate environment (rate capability of the order of MHz cm2) is under developmnet. Semi-conductive electrodes with resistivity ρ up to 108 Ωcm have been used to improve the RPC [1,2] rate capability. In this paper efficiency and time resolution of three different detector structures are presented. | - |
dc.language | eng | - |
dc.relation.ispartof | Journal of Instrumentation | - |
dc.subject | Gaseous detectors | - |
dc.subject | Resistive-plate chambers | - |
dc.subject | Solid state detectors | - |
dc.title | RPC detectors with semiconductive electrodes: efficiency and time resolution measurements | - |
dc.type | Conference_Paper | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1088/1748-0221/14/12/C12005 | - |
dc.identifier.scopus | eid_2-s2.0-85080041550 | - |
dc.identifier.volume | 14 | - |
dc.identifier.issue | 12 | - |
dc.identifier.spage | article no. C12005 | - |
dc.identifier.epage | article no. C12005 | - |
dc.identifier.eissn | 1748-0221 | - |
dc.identifier.isi | WOS:000510148700005 | - |