File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Conference Paper: RPC detectors with semiconductive electrodes: efficiency and time resolution measurements

TitleRPC detectors with semiconductive electrodes: efficiency and time resolution measurements
Authors
KeywordsGaseous detectors
Resistive-plate chambers
Solid state detectors
Issue Date2019
Citation
Journal of Instrumentation, 2019, v. 14, n. 12, article no. C12005 How to Cite?
AbstractA new particle detector with sub-nanosecond time resolution capable of working in high-rate environment (rate capability of the order of MHz cm2) is under developmnet. Semi-conductive electrodes with resistivity ρ up to 108 Ωcm have been used to improve the RPC [1,2] rate capability. In this paper efficiency and time resolution of three different detector structures are presented.
Persistent Identifierhttp://hdl.handle.net/10722/327587
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorRocchi, A.-
dc.contributor.authorCardarelli, R.-
dc.contributor.authorAielli, G.-
dc.contributor.authorCamelia, E. Alunno-
dc.contributor.authorBruno, S.-
dc.contributor.authorCaltabiano, A.-
dc.contributor.authorCamarri, P.-
dc.contributor.authorDi Ciaccio, A.-
dc.contributor.authorLiberti, B.-
dc.contributor.authorMassa, L.-
dc.contributor.authorPizzimento, L.-
dc.date.accessioned2023-04-03T12:27:51Z-
dc.date.available2023-04-03T12:27:51Z-
dc.date.issued2019-
dc.identifier.citationJournal of Instrumentation, 2019, v. 14, n. 12, article no. C12005-
dc.identifier.urihttp://hdl.handle.net/10722/327587-
dc.description.abstractA new particle detector with sub-nanosecond time resolution capable of working in high-rate environment (rate capability of the order of MHz cm2) is under developmnet. Semi-conductive electrodes with resistivity ρ up to 108 Ωcm have been used to improve the RPC [1,2] rate capability. In this paper efficiency and time resolution of three different detector structures are presented.-
dc.languageeng-
dc.relation.ispartofJournal of Instrumentation-
dc.subjectGaseous detectors-
dc.subjectResistive-plate chambers-
dc.subjectSolid state detectors-
dc.titleRPC detectors with semiconductive electrodes: efficiency and time resolution measurements-
dc.typeConference_Paper-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1088/1748-0221/14/12/C12005-
dc.identifier.scopuseid_2-s2.0-85080041550-
dc.identifier.volume14-
dc.identifier.issue12-
dc.identifier.spagearticle no. C12005-
dc.identifier.epagearticle no. C12005-
dc.identifier.eissn1748-0221-
dc.identifier.isiWOS:000510148700005-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats