Article: Alkali and alkaline earth metal ion-sensing studies on two disubstituted diphenyl ethers of tetraethylene glycol
Title | Alkali and alkaline earth metal ion-sensing studies on two disubstituted diphenyl ethers of tetraethylene glycol |
---|---|
Authors | |
Keywords | Acyclic polyethers Neutral and diphenolic carriers Pvc matrix ion-selective electrodes Solvent mediators |
Issue Date | 1988 |
Citation | The Analyst, 1988, v. 113, p. 1295-1298 How to Cite? |
Abstract | The acyclic polyethers 1,11-bis(2-hydroxy-5-formylphenoxy)-3,6,9- trioxaundecane (1) and its dibenzyl ether (2) were evaluated individually, when incorporated with seven different solvent mediators and, in some instances, also with an anion excluder, as possible alkali and alkaline earth metal ion sensors. The response characteristics of the diphenol 1 are more dependent on the solvent mediator used whereas the dibenzyl ether 2 shows a preferential response towards potassium ions regardless of the solvent mediator used. The solvent mediators themselves were also checked for their ion-sensing qualities: tris(2-ethylhexyl) phosphate and dioctyl phenylphosphonate both exhibit a substantial response towards lithium ions; dioctyl sebacate, dibutyl phthalate and bis(2-ethylhexyl) adipate all show some response towards potassium ions. |
Persistent Identifier | http://hdl.handle.net/10722/332338 |
ISSN | 2023 Impact Factor: 3.6 2023 SCImago Journal Rankings: 0.693 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Moody, G. J. | - |
dc.contributor.author | Saad, Bahruddin B. | - |
dc.contributor.author | Thomas, J. D.R. | - |
dc.contributor.author | Kohnket, F. H. | - |
dc.contributor.author | Stoddart, J. F. | - |
dc.date.accessioned | 2023-10-06T05:10:41Z | - |
dc.date.available | 2023-10-06T05:10:41Z | - |
dc.date.issued | 1988 | - |
dc.identifier.citation | The Analyst, 1988, v. 113, p. 1295-1298 | - |
dc.identifier.issn | 0003-2654 | - |
dc.identifier.uri | http://hdl.handle.net/10722/332338 | - |
dc.description.abstract | The acyclic polyethers 1,11-bis(2-hydroxy-5-formylphenoxy)-3,6,9- trioxaundecane (1) and its dibenzyl ether (2) were evaluated individually, when incorporated with seven different solvent mediators and, in some instances, also with an anion excluder, as possible alkali and alkaline earth metal ion sensors. The response characteristics of the diphenol 1 are more dependent on the solvent mediator used whereas the dibenzyl ether 2 shows a preferential response towards potassium ions regardless of the solvent mediator used. The solvent mediators themselves were also checked for their ion-sensing qualities: tris(2-ethylhexyl) phosphate and dioctyl phenylphosphonate both exhibit a substantial response towards lithium ions; dioctyl sebacate, dibutyl phthalate and bis(2-ethylhexyl) adipate all show some response towards potassium ions. | - |
dc.language | eng | - |
dc.relation.ispartof | The Analyst | - |
dc.subject | Acyclic polyethers | - |
dc.subject | Neutral and diphenolic carriers | - |
dc.subject | Pvc matrix ion-selective electrodes | - |
dc.subject | Solvent mediators | - |
dc.title | Alkali and alkaline earth metal ion-sensing studies on two disubstituted diphenyl ethers of tetraethylene glycol | - |