postgraduate thesis: Technical assessment of automatic exposure control of the digital mammography system-hologic dimensions : balance of the breast dose with image quality
| Title | Technical assessment of automatic exposure control of the digital mammography system-hologic dimensions : balance of the breast dose with image quality |
|---|---|
| Authors | |
| Issue Date | 2023 |
| Publisher | The University of Hong Kong (Pokfulam, Hong Kong) |
| Citation | Li, T. Y. [李德譽]. (2023). Technical assessment of automatic exposure control of the digital mammography system-hologic dimensions : balance of the breast dose with image quality. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. |
| Degree | Master of Medical Sciences |
| Subject | Breast - Radiography Radiation - Dosage Radiography, Medical - Image quality |
| Dept/Program | Diagnostic Radiology |
| Persistent Identifier | http://hdl.handle.net/10722/335495 |
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Li, Tak Yu | - |
| dc.contributor.author | 李德譽 | - |
| dc.date.accessioned | 2023-11-21T09:13:42Z | - |
| dc.date.available | 2023-11-21T09:13:42Z | - |
| dc.date.issued | 2023 | - |
| dc.identifier.citation | Li, T. Y. [李德譽]. (2023). Technical assessment of automatic exposure control of the digital mammography system-hologic dimensions : balance of the breast dose with image quality. (Thesis). University of Hong Kong, Pokfulam, Hong Kong SAR. | - |
| dc.identifier.uri | http://hdl.handle.net/10722/335495 | - |
| dc.language | eng | - |
| dc.publisher | The University of Hong Kong (Pokfulam, Hong Kong) | - |
| dc.relation.ispartof | HKU Theses Online (HKUTO) | - |
| dc.rights | The author retains all proprietary rights, (such as patent rights) and the right to use in future works. | - |
| dc.rights | This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. | - |
| dc.subject.lcsh | Breast - Radiography | - |
| dc.subject.lcsh | Radiation - Dosage | - |
| dc.subject.lcsh | Radiography, Medical - Image quality | - |
| dc.title | Technical assessment of automatic exposure control of the digital mammography system-hologic dimensions : balance of the breast dose with image quality | - |
| dc.type | PG_Thesis | - |
| dc.description.thesisname | Master of Medical Sciences | - |
| dc.description.thesislevel | Master | - |
| dc.description.thesisdiscipline | Diagnostic Radiology | - |
| dc.description.nature | published_or_final_version | - |
| dc.date.hkucongregation | 2023 | - |
| dc.identifier.mmsid | 991044730784203414 | - |