File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Temperature-dependent helium induced microstructural evolution in equiatomic NiCo and NiFe concentrated solid solution alloys

TitleTemperature-dependent helium induced microstructural evolution in equiatomic NiCo and NiFe concentrated solid solution alloys
Authors
KeywordsDislocation loop
He cavity
Irradiation temperature
Single-phase concentrated solid-solution alloy
Issue Date2021
Citation
Journal of Nuclear Materials, 2021, v. 545, article no. 152715 How to Cite?
AbstractIrradiation temperature and the species of elemental constituents are two pivotal factors in determining the helium (He) radiation behaviors. However, their synergistic effect on the He-induced defect evolution in single-phase concentrated solid-solution alloys (SP-CSSAs) has rarely been studied. In this work, the evolution of He cavities and dislocation structural damages in two equiatomic SP-CSSAs, i.e., NiCo and NiFe, were investigated at 673 K, 773 K and 873 K with 275 keV He+ ions. He cavity formation behaviors were diverse at different temperature regimes. NiFe was found to have a stronger suppression effect on He cavity growth at 673 K. However, with the increasing temperature, a more pronounced increment of He cavity size was exhibited in NiFe. Unlike the evolution of He cavities, the growth of dislocation loops tends to be delayed in NiFe over the studied irradiation temperatures. The underlying mechanisms for the temperature-dependent defect evolution in NiCo and NiFe are discussed.
Persistent Identifierhttp://hdl.handle.net/10722/335858
ISSN
2023 Impact Factor: 2.8
2023 SCImago Journal Rankings: 0.923
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorLiu, Shaofei-
dc.contributor.authorChen, Da-
dc.contributor.authorZhao, Shijun-
dc.contributor.authorLin, Weitong-
dc.contributor.authorMeng, Fanling-
dc.contributor.authorZhao, Yilu-
dc.contributor.authorYeli, Guma-
dc.contributor.authorHe, Feng-
dc.contributor.authorLi, Yiran-
dc.contributor.authorNiu, Huan-
dc.contributor.authorKai, Ji jung-
dc.date.accessioned2023-12-28T08:49:16Z-
dc.date.available2023-12-28T08:49:16Z-
dc.date.issued2021-
dc.identifier.citationJournal of Nuclear Materials, 2021, v. 545, article no. 152715-
dc.identifier.issn0022-3115-
dc.identifier.urihttp://hdl.handle.net/10722/335858-
dc.description.abstractIrradiation temperature and the species of elemental constituents are two pivotal factors in determining the helium (He) radiation behaviors. However, their synergistic effect on the He-induced defect evolution in single-phase concentrated solid-solution alloys (SP-CSSAs) has rarely been studied. In this work, the evolution of He cavities and dislocation structural damages in two equiatomic SP-CSSAs, i.e., NiCo and NiFe, were investigated at 673 K, 773 K and 873 K with 275 keV He+ ions. He cavity formation behaviors were diverse at different temperature regimes. NiFe was found to have a stronger suppression effect on He cavity growth at 673 K. However, with the increasing temperature, a more pronounced increment of He cavity size was exhibited in NiFe. Unlike the evolution of He cavities, the growth of dislocation loops tends to be delayed in NiFe over the studied irradiation temperatures. The underlying mechanisms for the temperature-dependent defect evolution in NiCo and NiFe are discussed.-
dc.languageeng-
dc.relation.ispartofJournal of Nuclear Materials-
dc.subjectDislocation loop-
dc.subjectHe cavity-
dc.subjectIrradiation temperature-
dc.subjectSingle-phase concentrated solid-solution alloy-
dc.titleTemperature-dependent helium induced microstructural evolution in equiatomic NiCo and NiFe concentrated solid solution alloys-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/j.jnucmat.2020.152715-
dc.identifier.scopuseid_2-s2.0-85098459846-
dc.identifier.volume545-
dc.identifier.spagearticle no. 152715-
dc.identifier.epagearticle no. 152715-
dc.identifier.isiWOS:000608777700014-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats