File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Distributed generation placement for power distribution networks

TitleDistributed generation placement for power distribution networks
Authors
Keywordscross entropy
Design automation for smart grid system
distributed generator insertion
renewable energy
Issue Date2015
Citation
Journal of Circuits, Systems and Computers, 2015, v. 24, n. 1, article no. 1550009 How to Cite?
AbstractGrowing concerns on the energy crisis impose great challenges in development and deployment of the smart grid technologies into the existing electrical power system. A key enabling technology in smart grid is distributed generation, which refers to the technology that power generating sources are located in a highly distributed fashion and each customer is both a consumer and a producer for energy. An important optimization problem in distributed generation design is the insertion of distributed generators (DGs), which are often renewable resources exploiting e.g., photovoltaic, hydro, wind, ocean energy. In this paper, a new power loss filtering based sensitivity guided cross entropy (CE) algorithm is proposed for the distributed generator insertion problem. This algorithm is based on the advanced CE optimization technique which exploits the idea of importance sampling in performing optimization. Our experimental results demonstrate that on large distribution networks, our algorithm can largely reduce (up to 179.3%) power loss comparing to a state-of-the-art sensitivity guided greedy algorithm with small runtime overhead. In addition, our algorithm runs about 5× faster than the classical CE algorithm due to the integration of power loss filtering and sensitivity optimization. Moreover, all existing techniques only test on very small distribution systems (usually with < 50 nodes) while our experiments are performed on the distribution networks with up to 5000 nodes, which matches the realistic setup. These demonstrate the practicality of the proposed algorithm.
Persistent Identifierhttp://hdl.handle.net/10722/336134
ISSN
2023 Impact Factor: 0.9
2023 SCImago Journal Rankings: 0.298
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorChen, Xiaodao-
dc.contributor.authorHu, Shiyan-
dc.date.accessioned2024-01-15T08:23:47Z-
dc.date.available2024-01-15T08:23:47Z-
dc.date.issued2015-
dc.identifier.citationJournal of Circuits, Systems and Computers, 2015, v. 24, n. 1, article no. 1550009-
dc.identifier.issn0218-1266-
dc.identifier.urihttp://hdl.handle.net/10722/336134-
dc.description.abstractGrowing concerns on the energy crisis impose great challenges in development and deployment of the smart grid technologies into the existing electrical power system. A key enabling technology in smart grid is distributed generation, which refers to the technology that power generating sources are located in a highly distributed fashion and each customer is both a consumer and a producer for energy. An important optimization problem in distributed generation design is the insertion of distributed generators (DGs), which are often renewable resources exploiting e.g., photovoltaic, hydro, wind, ocean energy. In this paper, a new power loss filtering based sensitivity guided cross entropy (CE) algorithm is proposed for the distributed generator insertion problem. This algorithm is based on the advanced CE optimization technique which exploits the idea of importance sampling in performing optimization. Our experimental results demonstrate that on large distribution networks, our algorithm can largely reduce (up to 179.3%) power loss comparing to a state-of-the-art sensitivity guided greedy algorithm with small runtime overhead. In addition, our algorithm runs about 5× faster than the classical CE algorithm due to the integration of power loss filtering and sensitivity optimization. Moreover, all existing techniques only test on very small distribution systems (usually with < 50 nodes) while our experiments are performed on the distribution networks with up to 5000 nodes, which matches the realistic setup. These demonstrate the practicality of the proposed algorithm.-
dc.languageeng-
dc.relation.ispartofJournal of Circuits, Systems and Computers-
dc.subjectcross entropy-
dc.subjectDesign automation for smart grid system-
dc.subjectdistributed generator insertion-
dc.subjectrenewable energy-
dc.titleDistributed generation placement for power distribution networks-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1142/S0218126615500097-
dc.identifier.scopuseid_2-s2.0-84928377535-
dc.identifier.volume24-
dc.identifier.issue1-
dc.identifier.spagearticle no. 1550009-
dc.identifier.epagearticle no. 1550009-
dc.identifier.isiWOS:000350769900010-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats