File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Co-placement optimization in sensor-reusable cyber-physical digital microfluidic biochips

TitleCo-placement optimization in sensor-reusable cyber-physical digital microfluidic biochips
Authors
KeywordsCyber-physical sys-tem
Digital microfluidic biochips
Placement
Reliability
Sensor
Issue Date2019
Citation
Microelectronics Journal, 2019, v. 83, p. 185-196 How to Cite?
AbstractDigital microfluidic biochips (DMFBs) facilitate modern healthcare applications. One of the most important applications is point-of-care (POC) clinical diagnosis which is directly related to human health. However, biochemical experiments are usually error-prone, which makes monitoring intermediate results during bioassay execution be required to ensure the correctness of POC clinical diagnosis. To tackle this problem, cyber-physical digital microfluidic biochips with integrated sensors have been proposed and have attracted attention recently. In order to fully utilize the sensors for detection, the reusability of sensors should be taken into consideration during the module placement stage of cyber-physical DMFBs synthesis flow. Moreover, excessive actuation of electrodes may cause reliability degradation and this issuse should also be taken care of during module placement stage. In order to deal with the aforementioned problems, this paper presents the first co-optimization method for both module and sensor placement. Experimental results show that the proposed method can effectively minimize bioassay completion time while meeting all constraints from sensors and electrodes.
Persistent Identifierhttp://hdl.handle.net/10722/336210
ISSN
2023 Impact Factor: 1.9
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorLi, Jian De-
dc.contributor.authorKuo, Chun Hao-
dc.contributor.authorLu, Guan Ruei-
dc.contributor.authorWang, Sying Jyan-
dc.contributor.authorShu-Min Li, Katherine-
dc.contributor.authorHo, Tsung Yi-
dc.contributor.authorChen, Hung Ming-
dc.contributor.authorHu, Shiyan-
dc.date.accessioned2024-01-15T08:24:29Z-
dc.date.available2024-01-15T08:24:29Z-
dc.date.issued2019-
dc.identifier.citationMicroelectronics Journal, 2019, v. 83, p. 185-196-
dc.identifier.issn0026-2692-
dc.identifier.urihttp://hdl.handle.net/10722/336210-
dc.description.abstractDigital microfluidic biochips (DMFBs) facilitate modern healthcare applications. One of the most important applications is point-of-care (POC) clinical diagnosis which is directly related to human health. However, biochemical experiments are usually error-prone, which makes monitoring intermediate results during bioassay execution be required to ensure the correctness of POC clinical diagnosis. To tackle this problem, cyber-physical digital microfluidic biochips with integrated sensors have been proposed and have attracted attention recently. In order to fully utilize the sensors for detection, the reusability of sensors should be taken into consideration during the module placement stage of cyber-physical DMFBs synthesis flow. Moreover, excessive actuation of electrodes may cause reliability degradation and this issuse should also be taken care of during module placement stage. In order to deal with the aforementioned problems, this paper presents the first co-optimization method for both module and sensor placement. Experimental results show that the proposed method can effectively minimize bioassay completion time while meeting all constraints from sensors and electrodes.-
dc.languageeng-
dc.relation.ispartofMicroelectronics Journal-
dc.subjectCyber-physical sys-tem-
dc.subjectDigital microfluidic biochips-
dc.subjectPlacement-
dc.subjectReliability-
dc.subjectSensor-
dc.titleCo-placement optimization in sensor-reusable cyber-physical digital microfluidic biochips-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/j.mejo.2018.08.005-
dc.identifier.scopuseid_2-s2.0-85059948940-
dc.identifier.volume83-
dc.identifier.spage185-
dc.identifier.epage196-
dc.identifier.isiWOS:000456730500021-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats