File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Evaluation of Porous Titanium Structures and Lightweight for Mandibular Prosthesis

TitleEvaluation of Porous Titanium Structures and Lightweight for Mandibular Prosthesis
Authors
KeywordsConfiguration
Lightweight
Mandibular prosthesis
Mechanical properties
Issue Date1-Dec-2022
PublisherSpringer
Citation
Journal of Medical and Biological Engineering, 2022, v. 42, n. 6, p. 922-930 How to Cite?
Abstract

Purpose

The increased permeability of high porosity implants facilitates the easy diffusion of nutrients and the delivery of sufficient cellular mass for tissue repair. Therefore, this study aims to investigate the mechanical properties of the porous lattice scaffolds with four configurations and their application in designing a lightweight mandibular prosthesis.

Methods

Lattice scaffolds with four configurations (regular hexahedron, regular octahedron, rhombic dodecahedron, and body-centered cubic) and four porosities (60%, 70%, 80%, and 90%) were fabricated using selective laser manufacturing and their mechanical properties were evaluated by compression tests. Subsequently, a Gibson-Ashby model was developed to fit the porosity-stress curve of the scaffold. Furthermore, the lightweight design of the mandibular prosthesis was achieved by combining the maximum stress in the mandibular defect region and porosity-stress curves.

Results

The load transmission capacity of the scaffold was strongly correlated with both the configuration and porosity. Mechanical properties were negatively correlated with porosity under the same configuration; the regular hexahedron scaffold performed better at the same porosity. Mandibular prosthesis porosity with different configurations showed a difference of up to 8.4% (73.4% for body-centered cubic and 81.8% for regular hexahedron) and a gradient change with the maximum stress value of the defect region.

Conclusion

The lightweight prosthesis design method proposed in our study minimizes material wastage while maintaining its mechanical properties, providing a reference for stabilized mandibular reconstruction.


Persistent Identifierhttp://hdl.handle.net/10722/337593
ISSN
2021 Impact Factor: 2.213
2020 SCImago Journal Rankings: 0.300
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorLiu, RS-
dc.contributor.authorSu, YX-
dc.contributor.authorYang, WF-
dc.contributor.authorWang, G-
dc.contributor.authorDu RX-
dc.contributor.authorZhong, Y-
dc.date.accessioned2024-03-11T10:22:20Z-
dc.date.available2024-03-11T10:22:20Z-
dc.date.issued2022-12-01-
dc.identifier.citationJournal of Medical and Biological Engineering, 2022, v. 42, n. 6, p. 922-930-
dc.identifier.issn1609-0985-
dc.identifier.urihttp://hdl.handle.net/10722/337593-
dc.description.abstract<h3>Purpose</h3><p>The increased permeability of high porosity implants facilitates the easy diffusion of nutrients and the delivery of sufficient cellular mass for tissue repair. Therefore, this study aims to investigate the mechanical properties of the porous lattice scaffolds with four configurations and their application in designing a lightweight mandibular prosthesis.</p><h3>Methods</h3><p>Lattice scaffolds with four configurations (regular hexahedron, regular octahedron, rhombic dodecahedron, and body-centered cubic) and four porosities (60%, 70%, 80%, and 90%) were fabricated using selective laser manufacturing and their mechanical properties were evaluated by compression tests. Subsequently, a Gibson-Ashby model was developed to fit the porosity-stress curve of the scaffold. Furthermore, the lightweight design of the mandibular prosthesis was achieved by combining the maximum stress in the mandibular defect region and porosity-stress curves.</p><h3>Results</h3><p>The load transmission capacity of the scaffold was strongly correlated with both the configuration and porosity. Mechanical properties were negatively correlated with porosity under the same configuration; the regular hexahedron scaffold performed better at the same porosity. Mandibular prosthesis porosity with different configurations showed a difference of up to 8.4% (73.4% for body-centered cubic and 81.8% for regular hexahedron) and a gradient change with the maximum stress value of the defect region.</p><h3>Conclusion</h3><p>The lightweight prosthesis design method proposed in our study minimizes material wastage while maintaining its mechanical properties, providing a reference for stabilized mandibular reconstruction.</p>-
dc.languageeng-
dc.publisherSpringer-
dc.relation.ispartofJournal of Medical and Biological Engineering-
dc.rightsThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.-
dc.subjectConfiguration-
dc.subjectLightweight-
dc.subjectMandibular prosthesis-
dc.subjectMechanical properties-
dc.titleEvaluation of Porous Titanium Structures and Lightweight for Mandibular Prosthesis-
dc.typeArticle-
dc.identifier.doi10.1007/s40846-022-00760-1-
dc.identifier.scopuseid_2-s2.0-85142202717-
dc.identifier.volume42-
dc.identifier.issue6-
dc.identifier.spage922-
dc.identifier.epage930-
dc.identifier.eissn2199-4757-
dc.identifier.isiWOS:000885745300001-
dc.publisher.placeHEIDELBERG-
dc.identifier.issnl1609-0985-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats