File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.21037/jtd-21-1496
- Scopus: eid_2-s2.0-85138143745
- WOS: WOS:000804436800001
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Using discrete event simulation to optimize nucleic acid testing process for coronavirus disease 2019 (COVID-19)
Title | Using discrete event simulation to optimize nucleic acid testing process for coronavirus disease 2019 (COVID-19) |
---|---|
Authors | |
Keywords | Coronavirus disease 2019 (COVID-19) discrete event simulation (DES) nucleic acid detection process optimization |
Issue Date | 14-Jun-2023 |
Publisher | AME Publishing |
Citation | Journal of Thoracic Disease, 2022, v. 14, n. 6, p. 1794-1801 How to Cite? |
Abstract | The COVID-19 pandemic caused by severe acute respiratory coronavirus-2 (SARS-CoV-2) has placed enormous diagnostic burden on hospitals and testing laboratories. It is thus critical for such facilities to optimize the diagnostic process to enable maximum testing on minimum resources. The current standard of diagnosis is the detection of the viral nucleic acid in clinical specimens. Methods: In order to optimize the laboratory???s nucleic acid testing system for COVID-19, we performed a Discrete-Event-Simulation using the Arena Simulation Software to model the detection process based on the data obtained from the First Affiliated Hospital of Guangzhou Medical University (FAHGMU). The maximum of total time that specimens spent and the equipment consumption was compared under different scenarios in the model. Results: Seven scenarios were performed to simulate actual situation and improved situations. We analyzed conditions that adding a new nucleic acid extraction system (NAES), shifting a member from night duty to morning duty, using specimen tubes containing guanidine isothiocyanate (GITC), then tested the maximum testing capacity in the current number of technicians. In addition, the costs including personal protective equipment (PPE) and testing kits was calculated. Conclusions: A work schedule based on specimen-load improves efficiency without incurring additional costs, while using the specimen tubes containing GITC could reduce testing time by 30 min. In contrast, adding new NAESs or polymerase chain reaction (PCR) instruments has minimal impact on testing efficiency. |
Persistent Identifier | http://hdl.handle.net/10722/337893 |
ISSN | 2023 Impact Factor: 2.1 2023 SCImago Journal Rankings: 0.651 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Guan, WD | - |
dc.contributor.author | Zhou, JH | - |
dc.contributor.author | Huang, XD | - |
dc.contributor.author | Wu, SG | - |
dc.contributor.author | Wu, QB | - |
dc.contributor.author | Wong, SS | - |
dc.contributor.author | Yang, ZF | - |
dc.date.accessioned | 2024-03-11T10:24:43Z | - |
dc.date.available | 2024-03-11T10:24:43Z | - |
dc.date.issued | 2023-06-14 | - |
dc.identifier.citation | Journal of Thoracic Disease, 2022, v. 14, n. 6, p. 1794-1801 | - |
dc.identifier.issn | 2072-1439 | - |
dc.identifier.uri | http://hdl.handle.net/10722/337893 | - |
dc.description.abstract | <p>The COVID-19 pandemic caused by severe acute respiratory coronavirus-2 (SARS-CoV-2) has placed enormous diagnostic burden on hospitals and testing laboratories. It is thus critical for such facilities to optimize the diagnostic process to enable maximum testing on minimum resources. The current standard of diagnosis is the detection of the viral nucleic acid in clinical specimens. Methods: In order to optimize the laboratory???s nucleic acid testing system for COVID-19, we performed a Discrete-Event-Simulation using the Arena Simulation Software to model the detection process based on the data obtained from the First Affiliated Hospital of Guangzhou Medical University (FAHGMU). The maximum of total time that specimens spent and the equipment consumption was compared under different scenarios in the model. Results: Seven scenarios were performed to simulate actual situation and improved situations. We analyzed conditions that adding a new nucleic acid extraction system (NAES), shifting a member from night duty to morning duty, using specimen tubes containing guanidine isothiocyanate (GITC), then tested the maximum testing capacity in the current number of technicians. In addition, the costs including personal protective equipment (PPE) and testing kits was calculated. Conclusions: A work schedule based on specimen-load improves efficiency without incurring additional costs, while using the specimen tubes containing GITC could reduce testing time by 30 min. In contrast, adding new NAESs or polymerase chain reaction (PCR) instruments has minimal impact on testing efficiency.<br></p> | - |
dc.language | eng | - |
dc.publisher | AME Publishing | - |
dc.relation.ispartof | Journal of Thoracic Disease | - |
dc.rights | This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. | - |
dc.subject | Coronavirus disease 2019 (COVID-19) | - |
dc.subject | discrete event simulation (DES) | - |
dc.subject | nucleic acid detection | - |
dc.subject | process optimization | - |
dc.title | Using discrete event simulation to optimize nucleic acid testing process for coronavirus disease 2019 (COVID-19) | - |
dc.type | Article | - |
dc.identifier.doi | 10.21037/jtd-21-1496 | - |
dc.identifier.scopus | eid_2-s2.0-85138143745 | - |
dc.identifier.volume | 14 | - |
dc.identifier.issue | 6 | - |
dc.identifier.spage | 1794 | - |
dc.identifier.epage | 1801 | - |
dc.identifier.eissn | 2077-6624 | - |
dc.identifier.isi | WOS:000804436800001 | - |
dc.identifier.issnl | 2072-1439 | - |