File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1117/12.2254244
- Scopus: eid_2-s2.0-85020282832
- Find via
Supplementary
-
Citations:
- Scopus: 0
- Appears in Collections:
Conference Paper: View-interpolation of sparsely sampled sinogram using convolutional neural network
Title | View-interpolation of sparsely sampled sinogram using convolutional neural network |
---|---|
Authors | |
Keywords | Convolutional neural network Deep learning Sparse-view CT View-interpolation |
Issue Date | 2017 |
Citation | Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 2017, v. 10133, article no. 1013328 How to Cite? |
Abstract | Spare-view sampling and its associated iterative image reconstruction in computed tomography have actively investigated. Sparse-view CT technique is a viable option to low-dose CT, particularly in cone-beam CT (CBCT) applications, with advanced iterative image reconstructions with varying degrees of image artifacts. One of the artifacts that may occur in sparse-view CT is the streak artifact in the reconstructed images. Another approach has been investigated for sparse-view CT imaging by use of the interpolation methods to fill in the missing view data and that reconstructs the image by an analytic reconstruction algorithm. In this study, we developed an interpolation method using convolutional neural network (CNN), which is one of the widely used deep-learning methods, to find missing projection data and compared its performances with the other interpolation techniques. |
Persistent Identifier | http://hdl.handle.net/10722/345803 |
ISSN | 2023 SCImago Journal Rankings: 0.226 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Hoyeon | - |
dc.contributor.author | Lee, Jongha | - |
dc.contributor.author | Cho, Suengryong | - |
dc.date.accessioned | 2024-09-01T10:59:48Z | - |
dc.date.available | 2024-09-01T10:59:48Z | - |
dc.date.issued | 2017 | - |
dc.identifier.citation | Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 2017, v. 10133, article no. 1013328 | - |
dc.identifier.issn | 1605-7422 | - |
dc.identifier.uri | http://hdl.handle.net/10722/345803 | - |
dc.description.abstract | Spare-view sampling and its associated iterative image reconstruction in computed tomography have actively investigated. Sparse-view CT technique is a viable option to low-dose CT, particularly in cone-beam CT (CBCT) applications, with advanced iterative image reconstructions with varying degrees of image artifacts. One of the artifacts that may occur in sparse-view CT is the streak artifact in the reconstructed images. Another approach has been investigated for sparse-view CT imaging by use of the interpolation methods to fill in the missing view data and that reconstructs the image by an analytic reconstruction algorithm. In this study, we developed an interpolation method using convolutional neural network (CNN), which is one of the widely used deep-learning methods, to find missing projection data and compared its performances with the other interpolation techniques. | - |
dc.language | eng | - |
dc.relation.ispartof | Progress in Biomedical Optics and Imaging - Proceedings of SPIE | - |
dc.subject | Convolutional neural network | - |
dc.subject | Deep learning | - |
dc.subject | Sparse-view CT | - |
dc.subject | View-interpolation | - |
dc.title | View-interpolation of sparsely sampled sinogram using convolutional neural network | - |
dc.type | Conference_Paper | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1117/12.2254244 | - |
dc.identifier.scopus | eid_2-s2.0-85020282832 | - |
dc.identifier.volume | 10133 | - |
dc.identifier.spage | article no. 1013328 | - |
dc.identifier.epage | article no. 1013328 | - |