File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Enhanced metronidazole removal in seawater using a single-chamber bioelectrochemical system

TitleEnhanced metronidazole removal in seawater using a single-chamber bioelectrochemical system
Authors
KeywordsBacterial community
Bioelectrochemical system
Metronidazole removal
Seawater
Sulfate-reducing bacteria
Issue Date15-Mar-2024
PublisherElsevier
Citation
Water Research, 2024, v. 252 How to Cite?
Abstract

The aim of this study was to investigate the removal of metronidazole (MNZ) from seawater using a bioelectrochemical system (BES). Single-chamber BES (i.e., S-BES) and dual-chamber BES (i.e., D-BES) were constructed with carbon brush as the anode and cathode. With the inoculum of sea mud and 2 g/L of glucose as the substrate in seawater, S-BES and D-BES were acclimated to test the MNZ removal. Results showed that S-BES could remove almost 100 % of 200 mg/L MNZ within 120 h and remain stable within 10 cycles of operation (∼50 d) under the applied voltage of 0.8 V. The MNZ removal reached ∼100 % and 60.2 % in the cathodic and anodic chambers of D-BES fed by 100 mg/L MNZ under 0.8 V, respectively. The MNZ concentration of 200 mg/L significantly inhibited the sulfur metabolism, decreased the ratio of live to dead cells in the electrode biofilms, and thus reduced the SO42− removal in the S-BES. The MNZ degradation and S2– oxidation was mainly attributed to the cathodic and anodic biofilms of S-BES, respectively. Three degradation pathways of MNZ were proposed based on the identified intermediates and results of density functional theory calculations. The synergies among different genus species in the bacterial communities of biofilms, and between anodic and cathodic reactions could be responsible for the high performance of S-BES. Results from this study should be not only useful for the MNZ removal but also for effective MNZ inhibition of sulfate-reducing bacteria induced microbiologically influenced corrosion in seawater.


Persistent Identifierhttp://hdl.handle.net/10722/346046
ISSN
2023 Impact Factor: 11.4
2023 SCImago Journal Rankings: 3.596

 

DC FieldValueLanguage
dc.contributor.authorXin, Haoran-
dc.contributor.authorChen, Xindi-
dc.contributor.authorYe, Yongbei-
dc.contributor.authorLiao, Yongjun-
dc.contributor.authorLuo, Haiping-
dc.contributor.authorTang, Chuyang Y-
dc.contributor.authorLiu, Guangli-
dc.date.accessioned2024-09-07T00:30:17Z-
dc.date.available2024-09-07T00:30:17Z-
dc.date.issued2024-03-15-
dc.identifier.citationWater Research, 2024, v. 252-
dc.identifier.issn0043-1354-
dc.identifier.urihttp://hdl.handle.net/10722/346046-
dc.description.abstract<p>The aim of this study was to investigate the removal of metronidazole (MNZ) from seawater using a bioelectrochemical system (BES). Single-chamber BES (i.e., S-BES) and dual-chamber BES (i.e., D-BES) were constructed with carbon brush as the anode and cathode. With the inoculum of sea mud and 2 g/L of glucose as the substrate in seawater, S-BES and D-BES were acclimated to test the MNZ removal. Results showed that S-BES could remove almost 100 % of 200 mg/L MNZ within 120 h and remain stable within 10 cycles of operation (∼50 d) under the applied voltage of 0.8 V. The MNZ removal reached ∼100 % and 60.2 % in the cathodic and anodic chambers of D-BES fed by 100 mg/L MNZ under 0.8 V, respectively. The MNZ concentration of 200 mg/L significantly inhibited the sulfur metabolism, decreased the ratio of live to dead cells in the electrode biofilms, and thus reduced the SO42− removal in the S-BES. The MNZ degradation and S2– oxidation was mainly attributed to the cathodic and anodic biofilms of S-BES, respectively. Three degradation pathways of MNZ were proposed based on the identified intermediates and results of density functional theory calculations. The synergies among different genus species in the bacterial communities of biofilms, and between anodic and cathodic reactions could be responsible for the high performance of S-BES. Results from this study should be not only useful for the MNZ removal but also for effective MNZ inhibition of sulfate-reducing bacteria induced microbiologically influenced corrosion in seawater.</p>-
dc.languageeng-
dc.publisherElsevier-
dc.relation.ispartofWater Research-
dc.rightsThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.-
dc.subjectBacterial community-
dc.subjectBioelectrochemical system-
dc.subjectMetronidazole removal-
dc.subjectSeawater-
dc.subjectSulfate-reducing bacteria-
dc.titleEnhanced metronidazole removal in seawater using a single-chamber bioelectrochemical system-
dc.typeArticle-
dc.identifier.doi10.1016/j.watres.2024.121212-
dc.identifier.pmid38320394-
dc.identifier.scopuseid_2-s2.0-85184021297-
dc.identifier.volume252-
dc.identifier.eissn1879-2448-
dc.identifier.issnl0043-1354-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats