File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/j.jcsr.2013.05.006
- Scopus: eid_2-s2.0-84878372773
- Find via
Supplementary
-
Citations:
- Scopus: 0
- Appears in Collections:
Article: Detailing of I-beam-to-CHS column joints with external diaphragm plates for seismic actions
Title | Detailing of I-beam-to-CHS column joints with external diaphragm plates for seismic actions |
---|---|
Authors | |
Keywords | External diaphragm plates Moment-rotation behavior Seismic performance Strain concentration |
Issue Date | 2013 |
Citation | Journal of Constructional Steel Research, 2013, v. 88, p. 21-33 How to Cite? |
Abstract | In this paper monotonic and cyclic finite element (FE) analyses are presented for the development of an I-beam-to-CHS column steel moment joint for seismic actions. The development process for the final joint details includes: (1) eliminating two identified structural deficiencies of distortion in column web panel and strain concentrations in the external diaphragms; (2) creating a multi-fuse energy dissipation mechanism; (3) devising a joint to delay onset of beam yielding. Two external diaphragm collar plates are welded to the circumference of the CHS column for connection to beam flanges. Various collar ring widths are examined for these horizontal diaphragms and a width (based on achieving full strength of the beam flanges) is found to produce an acceptable web panel performance. Different types of stiffener geometries in the connection region are then trialed to eliminate strain concentrations in the diaphragms. Two pairs of triangular diaphragm stiffeners are found to provide the desired performance. In order to produce a multi-fuse energy dissipation mechanism, tapered cover plates (TCPs) equipped with vertical stiffeners (VSs) are integrated into the joint. Oversized web holes of 4-10 mm are required to enable inelastic deformation for an overall joint rotation of 60-100 mrad, without undesirable web distortion. Further FE analyses are used to design the TCPs and VSs so they can be replaceable link post-seismic actions. For the final joint detailing it is shown that 6 mm oversized holes for the TCPs will delay the occurrence of yielding in the beam until the joint rotation is 70 mrad. © 2013 Elsevier Ltd. |
Persistent Identifier | http://hdl.handle.net/10722/348998 |
ISSN | 2023 Impact Factor: 4.0 2023 SCImago Journal Rankings: 1.261 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bagheri Sabbagh, Alireza | - |
dc.contributor.author | Chan, Tak Ming | - |
dc.contributor.author | Mottram, James Toby | - |
dc.date.accessioned | 2024-10-17T06:55:32Z | - |
dc.date.available | 2024-10-17T06:55:32Z | - |
dc.date.issued | 2013 | - |
dc.identifier.citation | Journal of Constructional Steel Research, 2013, v. 88, p. 21-33 | - |
dc.identifier.issn | 0143-974X | - |
dc.identifier.uri | http://hdl.handle.net/10722/348998 | - |
dc.description.abstract | In this paper monotonic and cyclic finite element (FE) analyses are presented for the development of an I-beam-to-CHS column steel moment joint for seismic actions. The development process for the final joint details includes: (1) eliminating two identified structural deficiencies of distortion in column web panel and strain concentrations in the external diaphragms; (2) creating a multi-fuse energy dissipation mechanism; (3) devising a joint to delay onset of beam yielding. Two external diaphragm collar plates are welded to the circumference of the CHS column for connection to beam flanges. Various collar ring widths are examined for these horizontal diaphragms and a width (based on achieving full strength of the beam flanges) is found to produce an acceptable web panel performance. Different types of stiffener geometries in the connection region are then trialed to eliminate strain concentrations in the diaphragms. Two pairs of triangular diaphragm stiffeners are found to provide the desired performance. In order to produce a multi-fuse energy dissipation mechanism, tapered cover plates (TCPs) equipped with vertical stiffeners (VSs) are integrated into the joint. Oversized web holes of 4-10 mm are required to enable inelastic deformation for an overall joint rotation of 60-100 mrad, without undesirable web distortion. Further FE analyses are used to design the TCPs and VSs so they can be replaceable link post-seismic actions. For the final joint detailing it is shown that 6 mm oversized holes for the TCPs will delay the occurrence of yielding in the beam until the joint rotation is 70 mrad. © 2013 Elsevier Ltd. | - |
dc.language | eng | - |
dc.relation.ispartof | Journal of Constructional Steel Research | - |
dc.subject | External diaphragm plates | - |
dc.subject | Moment-rotation behavior | - |
dc.subject | Seismic performance | - |
dc.subject | Strain concentration | - |
dc.title | Detailing of I-beam-to-CHS column joints with external diaphragm plates for seismic actions | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/j.jcsr.2013.05.006 | - |
dc.identifier.scopus | eid_2-s2.0-84878372773 | - |
dc.identifier.volume | 88 | - |
dc.identifier.spage | 21 | - |
dc.identifier.epage | 33 | - |