Article: Experimental study on column buckling of 420 MPa high strength steel welded circular tubes

TitleExperimental study on column buckling of 420 MPa high strength steel welded circular tubes
Authors
Keywords420 MPa high strength steel
Column buckling
Column test
Design method
Finite element analysis
Welded circular steel tube
Issue Date2014
Citation
Journal of Constructional Steel Research, 2014, v. 100, p. 71-81 How to Cite?
AbstractThis paper investigates the column buckling performance of welded circular tubes made of 420 MPa high strength steel (HSS). 24 axial compression column tests on specimens with a nominal diameter of 273 mm and thickness of 6 mm were conducted. Initial geometric imperfections including out-of-straightness and loading eccentricity were measured. Experimental results in terms of buckling modes and load-carrying capacities are presented and discussed in detail. Non-linear finite element (FE) models were developed which captured the experimental observations satisfactorily. Based on the validated FE models, further parametric analyses incorporating 60 HSS numerically generated welded circular tubular columns with various section sizes were carried out. The resulting FE and experimental results were compared with the existing column design curves in Chinese, European and American codes. Numerical results showed that the design resistances calculated based on design curve a in both GB50017-2003 and Eurocode 3 and the design formula in the ANSI/AISC 360-10 could be adopted. In addition, to further improve the design efficiency, a column design curve based on Eurocode 3 formulation with a new imperfection factor of 0.17 was proposed for the design of such HSS welded tubular columns. © 2014 Elsevier Ltd.
Persistent Identifierhttp://hdl.handle.net/10722/349035
ISSN
2023 Impact Factor: 4.0
2023 SCImago Journal Rankings: 1.261

 

DC FieldValueLanguage
dc.contributor.authorShi, Gang-
dc.contributor.authorJiang, Xue-
dc.contributor.authorZhou, Wenjing-
dc.contributor.authorChan, Tak Ming-
dc.contributor.authorZhang, Yong-
dc.date.accessioned2024-10-17T06:55:50Z-
dc.date.available2024-10-17T06:55:50Z-
dc.date.issued2014-
dc.identifier.citationJournal of Constructional Steel Research, 2014, v. 100, p. 71-81-
dc.identifier.issn0143-974X-
dc.identifier.urihttp://hdl.handle.net/10722/349035-
dc.description.abstractThis paper investigates the column buckling performance of welded circular tubes made of 420 MPa high strength steel (HSS). 24 axial compression column tests on specimens with a nominal diameter of 273 mm and thickness of 6 mm were conducted. Initial geometric imperfections including out-of-straightness and loading eccentricity were measured. Experimental results in terms of buckling modes and load-carrying capacities are presented and discussed in detail. Non-linear finite element (FE) models were developed which captured the experimental observations satisfactorily. Based on the validated FE models, further parametric analyses incorporating 60 HSS numerically generated welded circular tubular columns with various section sizes were carried out. The resulting FE and experimental results were compared with the existing column design curves in Chinese, European and American codes. Numerical results showed that the design resistances calculated based on design curve a in both GB50017-2003 and Eurocode 3 and the design formula in the ANSI/AISC 360-10 could be adopted. In addition, to further improve the design efficiency, a column design curve based on Eurocode 3 formulation with a new imperfection factor of 0.17 was proposed for the design of such HSS welded tubular columns. © 2014 Elsevier Ltd.-
dc.languageeng-
dc.relation.ispartofJournal of Constructional Steel Research-
dc.subject420 MPa high strength steel-
dc.subjectColumn buckling-
dc.subjectColumn test-
dc.subjectDesign method-
dc.subjectFinite element analysis-
dc.subjectWelded circular steel tube-
dc.titleExperimental study on column buckling of 420 MPa high strength steel welded circular tubes-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/j.jcsr.2014.04.028-
dc.identifier.scopuseid_2-s2.0-84900437265-
dc.identifier.volume100-
dc.identifier.spage71-
dc.identifier.epage81-