File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Numerical investigation of the impacts of environmental conditions and breathing rate on droplet transmission during dental service

TitleNumerical investigation of the impacts of environmental conditions and breathing rate on droplet transmission during dental service
Authors
Issue Date24-Apr-2023
PublisherAmerican Institute of Physics
Citation
Physics of Fluids, 2023, v. 35, n. 4 How to Cite?
Abstract

Dental services are yet to return to a semblance of normality owing to the fear and uncertainty associated with the possible airborne transmission of diseases. The present study aims to investigate the impacts of environmental conditions [changes in ventilation location, ventilation rate, and relative humidity (RH)] and variations in dental patient's breathing rate on droplet transmission during dental service. Computational fluid dynamics simulation was performed based on our previous experimental study during ultrasonic scaling. The impacts of different factors were numerically analyzed by the final fate and proportion of emitted droplets in the dental surgery environment. The results revealed that about 85% of droplets deposited near the dental treatment region, where the patient's torso, face, and floor (dental chair) accounted for around 63%, 11%, and 8.5%, respectively. The change in the ventilation location had a small impact on the deposition of larger droplets ( > 60 μ m ), and a spatial region with high droplet mass concentration would be presented near the dental professional. The change in the ventilation rate from 5 to 8 ACH led to a 1.5% increment in the fraction of escaped droplets. 50% RH in dental environments was recommended to prevent droplets' fast evaporation and potential mold. Variations in the patient's breathing rate had little effect on the final fate and proportion of emitted droplets. Overall, environmental factors are suggested to maintain 50% RH and larger ACH in dental surgery environments. The findings can give policymakers insights into the role of environmental factors on infection control.


Persistent Identifierhttp://hdl.handle.net/10722/351512
ISSN
2023 Impact Factor: 4.1
2023 SCImago Journal Rankings: 1.050

 

DC FieldValueLanguage
dc.contributor.authorLi, Xiujie-
dc.contributor.authorMak, Cheuk Ming-
dc.contributor.authorAi, Zhengtao-
dc.contributor.authorMa, Kuen Wai-
dc.contributor.authorWong, Hai Ming-
dc.date.accessioned2024-11-21T00:35:10Z-
dc.date.available2024-11-21T00:35:10Z-
dc.date.issued2023-04-24-
dc.identifier.citationPhysics of Fluids, 2023, v. 35, n. 4-
dc.identifier.issn1070-6631-
dc.identifier.urihttp://hdl.handle.net/10722/351512-
dc.description.abstract<p>Dental services are yet to return to a semblance of normality owing to the fear and uncertainty associated with the possible airborne transmission of diseases. The present study aims to investigate the impacts of environmental conditions [changes in ventilation location, ventilation rate, and relative humidity (RH)] and variations in dental patient's breathing rate on droplet transmission during dental service. Computational fluid dynamics simulation was performed based on our previous experimental study during ultrasonic scaling. The impacts of different factors were numerically analyzed by the final fate and proportion of emitted droplets in the dental surgery environment. The results revealed that about 85% of droplets deposited near the dental treatment region, where the patient's torso, face, and floor (dental chair) accounted for around 63%, 11%, and 8.5%, respectively. The change in the ventilation location had a small impact on the deposition of larger droplets ( > 60 μ m ), and a spatial region with high droplet mass concentration would be presented near the dental professional. The change in the ventilation rate from 5 to 8 ACH led to a 1.5% increment in the fraction of escaped droplets. 50% RH in dental environments was recommended to prevent droplets' fast evaporation and potential mold. Variations in the patient's breathing rate had little effect on the final fate and proportion of emitted droplets. Overall, environmental factors are suggested to maintain 50% RH and larger ACH in dental surgery environments. The findings can give policymakers insights into the role of environmental factors on infection control.</p>-
dc.languageeng-
dc.publisherAmerican Institute of Physics-
dc.relation.ispartofPhysics of Fluids-
dc.rightsThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.-
dc.titleNumerical investigation of the impacts of environmental conditions and breathing rate on droplet transmission during dental service-
dc.typeArticle-
dc.identifier.doi10.1063/5.0144647-
dc.identifier.scopuseid_2-s2.0-85158106876-
dc.identifier.volume35-
dc.identifier.issue4-
dc.identifier.eissn1089-7666-
dc.identifier.issnl1070-6631-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats