File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1063/5.0144647
- Scopus: eid_2-s2.0-85158106876
- Find via
Supplementary
-
Citations:
- Scopus: 0
- Appears in Collections:
Article: Numerical investigation of the impacts of environmental conditions and breathing rate on droplet transmission during dental service
Title | Numerical investigation of the impacts of environmental conditions and breathing rate on droplet transmission during dental service |
---|---|
Authors | |
Issue Date | 24-Apr-2023 |
Publisher | American Institute of Physics |
Citation | Physics of Fluids, 2023, v. 35, n. 4 How to Cite? |
Abstract | Dental services are yet to return to a semblance of normality owing to the fear and uncertainty associated with the possible airborne transmission of diseases. The present study aims to investigate the impacts of environmental conditions [changes in ventilation location, ventilation rate, and relative humidity (RH)] and variations in dental patient's breathing rate on droplet transmission during dental service. Computational fluid dynamics simulation was performed based on our previous experimental study during ultrasonic scaling. The impacts of different factors were numerically analyzed by the final fate and proportion of emitted droplets in the dental surgery environment. The results revealed that about 85% of droplets deposited near the dental treatment region, where the patient's torso, face, and floor (dental chair) accounted for around 63%, 11%, and 8.5%, respectively. The change in the ventilation location had a small impact on the deposition of larger droplets ( > 60 μ m ), and a spatial region with high droplet mass concentration would be presented near the dental professional. The change in the ventilation rate from 5 to 8 ACH led to a 1.5% increment in the fraction of escaped droplets. 50% RH in dental environments was recommended to prevent droplets' fast evaporation and potential mold. Variations in the patient's breathing rate had little effect on the final fate and proportion of emitted droplets. Overall, environmental factors are suggested to maintain 50% RH and larger ACH in dental surgery environments. The findings can give policymakers insights into the role of environmental factors on infection control. |
Persistent Identifier | http://hdl.handle.net/10722/351512 |
ISSN | 2023 Impact Factor: 4.1 2023 SCImago Journal Rankings: 1.050 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Li, Xiujie | - |
dc.contributor.author | Mak, Cheuk Ming | - |
dc.contributor.author | Ai, Zhengtao | - |
dc.contributor.author | Ma, Kuen Wai | - |
dc.contributor.author | Wong, Hai Ming | - |
dc.date.accessioned | 2024-11-21T00:35:10Z | - |
dc.date.available | 2024-11-21T00:35:10Z | - |
dc.date.issued | 2023-04-24 | - |
dc.identifier.citation | Physics of Fluids, 2023, v. 35, n. 4 | - |
dc.identifier.issn | 1070-6631 | - |
dc.identifier.uri | http://hdl.handle.net/10722/351512 | - |
dc.description.abstract | <p>Dental services are yet to return to a semblance of normality owing to the fear and uncertainty associated with the possible airborne transmission of diseases. The present study aims to investigate the impacts of environmental conditions [changes in ventilation location, ventilation rate, and relative humidity (RH)] and variations in dental patient's breathing rate on droplet transmission during dental service. Computational fluid dynamics simulation was performed based on our previous experimental study during ultrasonic scaling. The impacts of different factors were numerically analyzed by the final fate and proportion of emitted droplets in the dental surgery environment. The results revealed that about 85% of droplets deposited near the dental treatment region, where the patient's torso, face, and floor (dental chair) accounted for around 63%, 11%, and 8.5%, respectively. The change in the ventilation location had a small impact on the deposition of larger droplets ( > 60 μ m ), and a spatial region with high droplet mass concentration would be presented near the dental professional. The change in the ventilation rate from 5 to 8 ACH led to a 1.5% increment in the fraction of escaped droplets. 50% RH in dental environments was recommended to prevent droplets' fast evaporation and potential mold. Variations in the patient's breathing rate had little effect on the final fate and proportion of emitted droplets. Overall, environmental factors are suggested to maintain 50% RH and larger ACH in dental surgery environments. The findings can give policymakers insights into the role of environmental factors on infection control.</p> | - |
dc.language | eng | - |
dc.publisher | American Institute of Physics | - |
dc.relation.ispartof | Physics of Fluids | - |
dc.rights | This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. | - |
dc.title | Numerical investigation of the impacts of environmental conditions and breathing rate on droplet transmission during dental service | - |
dc.type | Article | - |
dc.identifier.doi | 10.1063/5.0144647 | - |
dc.identifier.scopus | eid_2-s2.0-85158106876 | - |
dc.identifier.volume | 35 | - |
dc.identifier.issue | 4 | - |
dc.identifier.eissn | 1089-7666 | - |
dc.identifier.issnl | 1070-6631 | - |