File Download
  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Development of MRE-based metamaterial with adjustable frequency bandgap for seismic vibration isolation

TitleDevelopment of MRE-based metamaterial with adjustable frequency bandgap for seismic vibration isolation
Authors
Issue Date15-Aug-2024
PublisherElsevier
Citation
Journal of Building Engineering, 2024, v. 91 How to Cite?
Abstract

A seismic isolation system is an engineering method to prevent structures from the undesirable vibrations of earthquake. It involves using isolators, dampers, and bearings to decouple the superstructure from the ground during seismic waves by reducing the forces and accelerations transferred to the structure. The goal of this research is to investigate the tunable MRE-based metamaterial foundation for seismic vibration isolation. Metamaterials with adaptive and variable frequency band gaps are preferred because earthquakes have a wide range of frequencies. By varying the magnetic field intensity, a magnetorheological elastomer (MRE)-based metamaterial foundation can modify its Young's modulus and stiffness. The frequency band gap or frequency range of the MRE-based metamaterial foundation can be shifted by tunable material properties. Under the effect of a magnetic field, a uniaxial compression test was conducted to evaluate the Young's modulus of three types of MRE samples. Following the compression test, a series of numerical simulations in ABAQUS were carried out using a two-story framed building with RC and MRE-based metamaterial foundation. Three earthquake excitations are used: Bishop, Oroville, and Imperial Valley. The experimental results suggest that the magnetic field influences the MRE's Young's modulus. Similarly, numerical simulation studies indicate that the magnetic field influences the frequency band gap of the MRE-based metamaterial foundation. The FRF results of conventional RC foundation and MRE-based foundation are compared, highlighting the efficiency of MRE-based foundation in vibration control by reducing the seismic vibration of a structure by 68.5 %.


Persistent Identifierhttp://hdl.handle.net/10722/353943
ISSN
2023 Impact Factor: 6.7
2023 SCImago Journal Rankings: 1.397
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorShrestha, Priyanka-
dc.contributor.authorJoshi, Bhagirath-
dc.contributor.authorLi, Xiaoliang-
dc.contributor.authorRamaswamy, Nagesh-
dc.contributor.authorWang, Jiaji-
dc.contributor.authorShan, Xiaonan-
dc.contributor.authorMo, Y. L.-
dc.date.accessioned2025-02-04T00:35:31Z-
dc.date.available2025-02-04T00:35:31Z-
dc.date.issued2024-08-15-
dc.identifier.citationJournal of Building Engineering, 2024, v. 91-
dc.identifier.issn2352-7102-
dc.identifier.urihttp://hdl.handle.net/10722/353943-
dc.description.abstract<p>A seismic isolation system is an engineering method to prevent structures from the undesirable vibrations of earthquake. It involves using isolators, dampers, and bearings to decouple the superstructure from the ground during seismic waves by reducing the forces and accelerations transferred to the structure. The goal of this research is to investigate the tunable MRE-based metamaterial foundation for seismic vibration isolation. Metamaterials with adaptive and variable frequency band gaps are preferred because earthquakes have a wide range of frequencies. By varying the magnetic field intensity, a magnetorheological elastomer (MRE)-based metamaterial foundation can modify its Young's modulus and stiffness. The frequency band gap or frequency range of the MRE-based metamaterial foundation can be shifted by tunable material properties. Under the effect of a magnetic field, a uniaxial compression test was conducted to evaluate the Young's modulus of three types of MRE samples. Following the compression test, a series of numerical simulations in ABAQUS were carried out using a two-story framed building with RC and MRE-based metamaterial foundation. Three earthquake excitations are used: Bishop, Oroville, and Imperial Valley. The experimental results suggest that the magnetic field influences the MRE's Young's modulus. Similarly, numerical simulation studies indicate that the magnetic field influences the frequency band gap of the MRE-based metamaterial foundation. The FRF results of conventional RC foundation and MRE-based foundation are compared, highlighting the efficiency of MRE-based foundation in vibration control by reducing the seismic vibration of a structure by 68.5 %.</p>-
dc.languageeng-
dc.publisherElsevier-
dc.relation.ispartofJournal of Building Engineering-
dc.titleDevelopment of MRE-based metamaterial with adjustable frequency bandgap for seismic vibration isolation -
dc.typeArticle-
dc.identifier.doi10.1016/j.jobe.2024.109575-
dc.identifier.scopuseid_2-s2.0-85193201230-
dc.identifier.volume91-
dc.identifier.eissn2352-7102-
dc.identifier.isiWOS:001325792900001-
dc.identifier.issnl2352-7102-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats