File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.3390/diagnostics15060788
- Scopus: eid_2-s2.0-105001169214
- WOS: WOS:001452818300001
- Find via

Supplementary
- Citations:
- Appears in Collections:
Article: MRI Detection of Unknown Primary Tumours in the Head and Neck: What Is the Expected Normal Asymmetry in the Size of the Palatine Tonsils?
| Title | MRI Detection of Unknown Primary Tumours in the Head and Neck: What Is the Expected Normal Asymmetry in the Size of the Palatine Tonsils? |
|---|---|
| Authors | |
| Keywords | head and neck cancer detection MRI tonsillar asymmetry |
| Issue Date | 20-Mar-2025 |
| Publisher | MDPI |
| Citation | Diagnostics, 2025, v. 15, n. 6 How to Cite? |
| Abstract | Background/Objectives: The detection of unknown primary tumours in the palatine tonsils (PTs) on imaging relies heavily on asymmetry in size between the right and left sides, but the expected normal range in asymmetry is not well documented. This study aimed to document the expected range of asymmetry in the size of the PTs in adults without cancer. Methods: This retrospective study evaluated 250 pairs of normal PTs on MRIs of adults without head and neck cancer. The size (volume, V) of the PTs on the left and right sides were measured, and the percentage difference in volume (ΔV%) between the two sides was calculated. An additional analysis of PT volumes in 29 patients with ipsilateral early-stage palatine tonsillar cancer (PTCs) was performed. Results: In patients without PTC, the normal PTs had a mean volume of 3.0 ± 1.7 cm3, and there was a difference in size between the left and right PTs, showing a median ΔV% of 11.6% (range: 0.1–79.0%); most patients had a ΔV% of ≤40% (95%) for PTs. In patients with ipsilateral PTC, the normal PT had a smaller size compared with PTC (p < 0.01), showing a median ΔV% of 132.9% (range: 8.5–863.2%). Compared with patients without PTC, those with PTC showed a greater ΔV% (p < 0.01). An optimal ΔV% threshold of >39.6% achieved the best accuracy of 95% for identifying PTC. Conclusions: PTs are asymmetrical in size in adults without PTC. An additional analysis involving patients with PTC confirmed a threshold of ΔV% of 40% for PTs, which may be clinically valuable to help detect pathology using MRI. |
| Persistent Identifier | http://hdl.handle.net/10722/356889 |
| ISSN | 2023 Impact Factor: 3.0 2023 SCImago Journal Rankings: 0.667 |
| ISI Accession Number ID |
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Mao, Kaijing | - |
| dc.contributor.author | Ai, Qi Yong H. | - |
| dc.contributor.author | Hung, Kuo Feng | - |
| dc.contributor.author | Tse, Irene O. L. | - |
| dc.contributor.author | Leung, Ho Sang | - |
| dc.contributor.author | Liang, Yannis Yan | - |
| dc.contributor.author | Chen, Yu | - |
| dc.contributor.author | Wong, Lun M. | - |
| dc.contributor.author | Lam, W. K. Jacky | - |
| dc.contributor.author | King, Ann D. | - |
| dc.date.accessioned | 2025-06-22T00:35:19Z | - |
| dc.date.available | 2025-06-22T00:35:19Z | - |
| dc.date.issued | 2025-03-20 | - |
| dc.identifier.citation | Diagnostics, 2025, v. 15, n. 6 | - |
| dc.identifier.issn | 2075-4418 | - |
| dc.identifier.uri | http://hdl.handle.net/10722/356889 | - |
| dc.description.abstract | <p> <span>Background/Objectives: The detection of unknown primary tumours in the palatine tonsils (PTs) on imaging relies heavily on asymmetry in size between the right and left sides, but the expected normal range in asymmetry is not well documented. This study aimed to document the expected range of asymmetry in the size of the PTs in adults without cancer. Methods: This retrospective study evaluated 250 pairs of normal PTs on MRIs of adults without head and neck cancer. The size (volume, V) of the PTs on the left and right sides were measured, and the percentage difference in volume (ΔV%) between the two sides was calculated. An additional analysis of PT volumes in 29 patients with ipsilateral early-stage palatine tonsillar cancer (PTCs) was performed. Results: In patients without PTC, the normal PTs had a mean volume of 3.0 ± 1.7 cm</span><sup>3</sup><span>, and there was a difference in size between the left and right PTs, showing a median ΔV% of 11.6% (range: 0.1–79.0%); most patients had a ΔV% of ≤40% (95%) for PTs. In patients with ipsilateral PTC, the normal PT had a smaller size compared with PTC (p < 0.01), showing a median ΔV% of 132.9% (range: 8.5–863.2%). Compared with patients without PTC, those with PTC showed a greater ΔV% (p < 0.01). An optimal ΔV% threshold of >39.6% achieved the best accuracy of 95% for identifying PTC. Conclusions: PTs are asymmetrical in size in adults without PTC. An additional analysis involving patients with PTC confirmed a threshold of ΔV% of 40% for PTs, which may be clinically valuable to help detect pathology using MRI.</span> <br></p> | - |
| dc.language | eng | - |
| dc.publisher | MDPI | - |
| dc.relation.ispartof | Diagnostics | - |
| dc.rights | This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. | - |
| dc.subject | head and neck cancer detection | - |
| dc.subject | MRI | - |
| dc.subject | tonsillar asymmetry | - |
| dc.title | MRI Detection of Unknown Primary Tumours in the Head and Neck: What Is the Expected Normal Asymmetry in the Size of the Palatine Tonsils? | - |
| dc.type | Article | - |
| dc.identifier.doi | 10.3390/diagnostics15060788 | - |
| dc.identifier.scopus | eid_2-s2.0-105001169214 | - |
| dc.identifier.volume | 15 | - |
| dc.identifier.issue | 6 | - |
| dc.identifier.eissn | 2075-4418 | - |
| dc.identifier.isi | WOS:001452818300001 | - |
| dc.identifier.issnl | 2075-4418 | - |
