File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Ultralow emittance electron beams from a laser-wakefield accelerator

TitleUltralow emittance electron beams from a laser-wakefield accelerator
Authors
Issue Date2012
Citation
Physical Review Special Topics Accelerators and Beams, 2012, v. 15, n. 11, article no. 111302 How to Cite?
AbstractUsing quadrupole scan measurements we show laser-wakefield accelerated electrons to have a normalized transverse emittance of 0.21-0.02+0.01π at 245 MeV. We demonstrate a multishot and a single-shot method, the mean emittance values for both methods agree well. A simple model of the beam dynamics in the plasma density downramp at the accelerator exit matches the source size and divergence values inferred from the measurement. In the energy range of 245 to 300 MeV the normalized emittance remains constant. © 2012 Published by the American Physical Society.
Persistent Identifierhttp://hdl.handle.net/10722/364870

 

DC FieldValueLanguage
dc.contributor.authorWeingartner, R.-
dc.contributor.authorRaith, S.-
dc.contributor.authorPopp, A.-
dc.contributor.authorChou, S.-
dc.contributor.authorWenz, J.-
dc.contributor.authorKhrennikov, K.-
dc.contributor.authorHeigoldt, M.-
dc.contributor.authorMaier, A. R.-
dc.contributor.authorKajumba, N.-
dc.contributor.authorFuchs, M.-
dc.contributor.authorZeitler, B.-
dc.contributor.authorKrausz, F.-
dc.contributor.authorKarsch, S.-
dc.contributor.authorGrüner, F.-
dc.date.accessioned2025-10-30T08:35:50Z-
dc.date.available2025-10-30T08:35:50Z-
dc.date.issued2012-
dc.identifier.citationPhysical Review Special Topics Accelerators and Beams, 2012, v. 15, n. 11, article no. 111302-
dc.identifier.urihttp://hdl.handle.net/10722/364870-
dc.description.abstractUsing quadrupole scan measurements we show laser-wakefield accelerated electrons to have a normalized transverse emittance of 0.21-0.02+0.01π at 245 MeV. We demonstrate a multishot and a single-shot method, the mean emittance values for both methods agree well. A simple model of the beam dynamics in the plasma density downramp at the accelerator exit matches the source size and divergence values inferred from the measurement. In the energy range of 245 to 300 MeV the normalized emittance remains constant. © 2012 Published by the American Physical Society.-
dc.languageeng-
dc.relation.ispartofPhysical Review Special Topics Accelerators and Beams-
dc.titleUltralow emittance electron beams from a laser-wakefield accelerator-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1103/PhysRevSTAB.15.111302-
dc.identifier.scopuseid_2-s2.0-84870553740-
dc.identifier.volume15-
dc.identifier.issue11-
dc.identifier.spagearticle no. 111302-
dc.identifier.epagearticle no. 111302-
dc.identifier.eissn1098-4402-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats