Article: Propagation and evaporation of contaminated droplets, emission and exposure in surgery environments revealed by laser visualization and numerical characterization
| Title | Propagation and evaporation of contaminated droplets, emission and exposure in surgery environments revealed by laser visualization and numerical characterization |
|---|---|
| Authors | |
| Keywords | Droplets Humidity and temperature Laser visualization Mucosalivary fluid Surgery environment |
| Issue Date | 26-Jul-2024 |
| Publisher | Elsevier |
| Citation | Journal of Hazardous Materials, 2024, v. 477 How to Cite? |
| Abstract | The contaminated liquid mixture containing mucosalivary fluid and blood would be aerosolized during medical procedures, resulting in higher-risk exposures. The novelty of this research is integrating laser visualization and numerical characterization to assess the propagation and evaporation of contaminated droplets, and the interactive effects of humidity and temperature on exposure risks will be numerically evaluated in surgery environments. The numerical model evidenced by experiments can predict the mass balance of ejection droplets, the minimum required fallow time (FT) between appointments, and the disinfection region of greatest concern. Around 98.4 % of the ejection droplet mass will be removed after the cessation of ultrasonic scaling, while the initial droplet size smaller than 72.6μm will dehydrate and become airborne. The FT recommendation of 30 min is not over-cautious, and the extended FT (range of 28–37 min) should be instituted for low temperature (20.5 °C) and high humidity levels (60 %RH). The variation of the temperature and humidity in the range for human thermal comfort has little influence on the area of the disinfection region (0.15m2) and the cut-off size (72.6μm) of droplet deposition and suspension. This research can provide scientific evidence for the guidelines of environmental conditions in surgery rooms. |
| Persistent Identifier | http://hdl.handle.net/10722/367079 |
| ISSN | 2023 Impact Factor: 12.2 2023 SCImago Journal Rankings: 2.950 |
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Li, Xiujie | - |
| dc.contributor.author | Mak, Cheuk Ming | - |
| dc.contributor.author | Ai, Zhengtao | - |
| dc.contributor.author | Ma, Kuen Wai | - |
| dc.contributor.author | Wong, Hai Ming | - |
| dc.date.accessioned | 2025-12-03T00:35:22Z | - |
| dc.date.available | 2025-12-03T00:35:22Z | - |
| dc.date.issued | 2024-07-26 | - |
| dc.identifier.citation | Journal of Hazardous Materials, 2024, v. 477 | - |
| dc.identifier.issn | 0304-3894 | - |
| dc.identifier.uri | http://hdl.handle.net/10722/367079 | - |
| dc.description.abstract | <p>The contaminated liquid mixture containing mucosalivary fluid and blood would be aerosolized during medical procedures, resulting in higher-risk exposures. The novelty of this research is integrating laser visualization and numerical characterization to assess the propagation and evaporation of contaminated droplets, and the interactive effects of humidity and temperature on exposure risks will be numerically evaluated in surgery environments. The numerical model evidenced by experiments can predict the mass balance of ejection droplets, the minimum required fallow time (FT) between appointments, and the disinfection region of greatest concern. Around 98.4 % of the ejection droplet mass will be removed after the cessation of ultrasonic scaling, while the initial droplet size smaller than 72.6μm will dehydrate and become airborne. The FT recommendation of 30 min is not over-cautious, and the extended FT (range of 28–37 min) should be instituted for low temperature (20.5 °C) and high humidity levels (60 %RH). The variation of the temperature and humidity in the range for human thermal comfort has little influence on the area of the disinfection region (0.15m<sup>2</sup>) and the cut-off size (72.6μm) of droplet deposition and suspension. This research can provide scientific evidence for the guidelines of environmental conditions in surgery rooms.</p> | - |
| dc.language | eng | - |
| dc.publisher | Elsevier | - |
| dc.relation.ispartof | Journal of Hazardous Materials | - |
| dc.rights | This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. | - |
| dc.subject | Droplets | - |
| dc.subject | Humidity and temperature | - |
| dc.subject | Laser visualization | - |
| dc.subject | Mucosalivary fluid | - |
| dc.subject | Surgery environment | - |
| dc.title | Propagation and evaporation of contaminated droplets, emission and exposure in surgery environments revealed by laser visualization and numerical characterization | - |