File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Propagation and evaporation of contaminated droplets, emission and exposure in surgery environments revealed by laser visualization and numerical characterization

TitlePropagation and evaporation of contaminated droplets, emission and exposure in surgery environments revealed by laser visualization and numerical characterization
Authors
KeywordsDroplets
Humidity and temperature
Laser visualization
Mucosalivary fluid
Surgery environment
Issue Date26-Jul-2024
PublisherElsevier
Citation
Journal of Hazardous Materials, 2024, v. 477 How to Cite?
Abstract

The contaminated liquid mixture containing mucosalivary fluid and blood would be aerosolized during medical procedures, resulting in higher-risk exposures. The novelty of this research is integrating laser visualization and numerical characterization to assess the propagation and evaporation of contaminated droplets, and the interactive effects of humidity and temperature on exposure risks will be numerically evaluated in surgery environments. The numerical model evidenced by experiments can predict the mass balance of ejection droplets, the minimum required fallow time (FT) between appointments, and the disinfection region of greatest concern. Around 98.4 % of the ejection droplet mass will be removed after the cessation of ultrasonic scaling, while the initial droplet size smaller than 72.6μm will dehydrate and become airborne. The FT recommendation of 30 min is not over-cautious, and the extended FT (range of 28–37 min) should be instituted for low temperature (20.5 °C) and high humidity levels (60 %RH). The variation of the temperature and humidity in the range for human thermal comfort has little influence on the area of the disinfection region (0.15m2) and the cut-off size (72.6μm) of droplet deposition and suspension. This research can provide scientific evidence for the guidelines of environmental conditions in surgery rooms.


Persistent Identifierhttp://hdl.handle.net/10722/367079
ISSN
2023 Impact Factor: 12.2
2023 SCImago Journal Rankings: 2.950

 

DC FieldValueLanguage
dc.contributor.authorLi, Xiujie-
dc.contributor.authorMak, Cheuk Ming-
dc.contributor.authorAi, Zhengtao-
dc.contributor.authorMa, Kuen Wai-
dc.contributor.authorWong, Hai Ming-
dc.date.accessioned2025-12-03T00:35:22Z-
dc.date.available2025-12-03T00:35:22Z-
dc.date.issued2024-07-26-
dc.identifier.citationJournal of Hazardous Materials, 2024, v. 477-
dc.identifier.issn0304-3894-
dc.identifier.urihttp://hdl.handle.net/10722/367079-
dc.description.abstract<p>The contaminated liquid mixture containing mucosalivary fluid and blood would be aerosolized during medical procedures, resulting in higher-risk exposures. The novelty of this research is integrating laser visualization and numerical characterization to assess the propagation and evaporation of contaminated droplets, and the interactive effects of humidity and temperature on exposure risks will be numerically evaluated in surgery environments. The numerical model evidenced by experiments can predict the mass balance of ejection droplets, the minimum required fallow time (FT) between appointments, and the disinfection region of greatest concern. Around 98.4 % of the ejection droplet mass will be removed after the cessation of ultrasonic scaling, while the initial droplet size smaller than 72.6μm will dehydrate and become airborne. The FT recommendation of 30 min is not over-cautious, and the extended FT (range of 28–37 min) should be instituted for low temperature (20.5 °C) and high humidity levels (60 %RH). The variation of the temperature and humidity in the range for human thermal comfort has little influence on the area of the disinfection region (0.15m<sup>2</sup>) and the cut-off size (72.6μm) of droplet deposition and suspension. This research can provide scientific evidence for the guidelines of environmental conditions in surgery rooms.</p>-
dc.languageeng-
dc.publisherElsevier-
dc.relation.ispartofJournal of Hazardous Materials-
dc.rightsThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.-
dc.subjectDroplets-
dc.subjectHumidity and temperature-
dc.subjectLaser visualization-
dc.subjectMucosalivary fluid-
dc.subjectSurgery environment-
dc.titlePropagation and evaporation of contaminated droplets, emission and exposure in surgery environments revealed by laser visualization and numerical characterization-
dc.typeArticle-
dc.identifier.doi10.1016/j.jhazmat.2024.135338-
dc.identifier.pmid39084008-
dc.identifier.scopuseid_2-s2.0-85199896582-
dc.identifier.volume477-
dc.identifier.eissn1873-3336-
dc.identifier.issnl0304-3894-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats