File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1177/0310057X0803600605
- Scopus: eid_2-s2.0-56649109628
- PMID: 19115644
- WOS: WOS:000261964000004
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Comparison between sevoflurane/remifentanil and propofol/remifentanil anaesthesia in providing conditions for somatosensory evoked potential monitoring during scoliosis corrective surgery
Title | Comparison between sevoflurane/remifentanil and propofol/remifentanil anaesthesia in providing conditions for somatosensory evoked potential monitoring during scoliosis corrective surgery |
---|---|
Authors | |
Keywords | Anaesthetic Intravenous Monitoring Propofol Remifentanil Sevoflurane Somatosensory evoked potential Spinal Volatile |
Issue Date | 2008 |
Publisher | Australian Society of Anaesthetists. The Journal's web site is located at http://www.aaic.net.au |
Citation | Anaesthesia And Intensive Care, 2008, v. 36 n. 6, p. 779-785 How to Cite? |
Abstract | Somatosensory evoked potential (SSEP) monitoring is an important tool in spinal corrective surgery. Anaesthesia has a significant influence on SSEP monitoring and a technique which has the least and shortest suppressant effect on SSEP while facilitating a fast recovery from anaesthesia is ideal. We compared the effect of sevoflurane/remifentanil and propofol/remifentanil anaesthesia on SSEPs during scoliosis corrective surgery and assessed patients' clinical recovery profiles. Twenty patients with idiopathic scoliosis receiving surgical correction with intraoperative SSEP monitoring were prospectively randomised to receive sevoflurane/remifentanil anaesthesia or propofol/remifentanil anaesthesia. During surgery, changes in anaesthesia dose and physiological variables were recorded, while SSEP was continuously monitored. A simulated 'wake-up' test was performed postoperatively to assess speed and quality of recovery from anaesthesia. The effects of propofol and sevoflurane resulted in SSEP amplitude variability between 18.0%±3.5% to 28.7%±5.9% and SSEP latency variability within 1.3%±0.4% to 2.6%±1.2%. Patients receiving sevoflurane had faster suppression and faster recovery of SSEP amplitude compared to propofol (P <0.05), although propofol anaesthesia showed less within-patient variability in Cz amplitude and latency (P <0.05). On cessation of anaesthesia, time to eye-opening (5.2 vs. 16.5 minutes) and toe movement (5.4 vs. 17.4 minutes) was shorter following sevoflurane (all P <0.05). These findings indicate that propofol produces a better SSEP signal than sevoflurane. However, adjustments in sevoflurane concentration result in faster changes in the SSEP signal than propofol. Assessment of neurological function was facilitated more rapidly after sevoflurane anaesthesia. |
Persistent Identifier | http://hdl.handle.net/10722/58177 |
ISSN | 2023 Impact Factor: 1.1 2023 SCImago Journal Rankings: 0.534 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Fung, NY | en_HK |
dc.contributor.author | Hu, Y | en_HK |
dc.contributor.author | Irwin, MG | en_HK |
dc.contributor.author | Chow, BFM | en_HK |
dc.contributor.author | Yuen, MY | en_HK |
dc.date.accessioned | 2010-05-31T03:25:11Z | - |
dc.date.available | 2010-05-31T03:25:11Z | - |
dc.date.issued | 2008 | en_HK |
dc.identifier.citation | Anaesthesia And Intensive Care, 2008, v. 36 n. 6, p. 779-785 | en_HK |
dc.identifier.issn | 0310-057X | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/58177 | - |
dc.description.abstract | Somatosensory evoked potential (SSEP) monitoring is an important tool in spinal corrective surgery. Anaesthesia has a significant influence on SSEP monitoring and a technique which has the least and shortest suppressant effect on SSEP while facilitating a fast recovery from anaesthesia is ideal. We compared the effect of sevoflurane/remifentanil and propofol/remifentanil anaesthesia on SSEPs during scoliosis corrective surgery and assessed patients' clinical recovery profiles. Twenty patients with idiopathic scoliosis receiving surgical correction with intraoperative SSEP monitoring were prospectively randomised to receive sevoflurane/remifentanil anaesthesia or propofol/remifentanil anaesthesia. During surgery, changes in anaesthesia dose and physiological variables were recorded, while SSEP was continuously monitored. A simulated 'wake-up' test was performed postoperatively to assess speed and quality of recovery from anaesthesia. The effects of propofol and sevoflurane resulted in SSEP amplitude variability between 18.0%±3.5% to 28.7%±5.9% and SSEP latency variability within 1.3%±0.4% to 2.6%±1.2%. Patients receiving sevoflurane had faster suppression and faster recovery of SSEP amplitude compared to propofol (P <0.05), although propofol anaesthesia showed less within-patient variability in Cz amplitude and latency (P <0.05). On cessation of anaesthesia, time to eye-opening (5.2 vs. 16.5 minutes) and toe movement (5.4 vs. 17.4 minutes) was shorter following sevoflurane (all P <0.05). These findings indicate that propofol produces a better SSEP signal than sevoflurane. However, adjustments in sevoflurane concentration result in faster changes in the SSEP signal than propofol. Assessment of neurological function was facilitated more rapidly after sevoflurane anaesthesia. | en_HK |
dc.language | eng | en_HK |
dc.publisher | Australian Society of Anaesthetists. The Journal's web site is located at http://www.aaic.net.au | en_HK |
dc.relation.ispartof | Anaesthesia and Intensive Care | en_HK |
dc.subject | Anaesthetic | en_HK |
dc.subject | Intravenous | en_HK |
dc.subject | Monitoring | en_HK |
dc.subject | Propofol | en_HK |
dc.subject | Remifentanil | en_HK |
dc.subject | Sevoflurane | en_HK |
dc.subject | Somatosensory evoked potential | en_HK |
dc.subject | Spinal | en_HK |
dc.subject | Volatile | en_HK |
dc.title | Comparison between sevoflurane/remifentanil and propofol/remifentanil anaesthesia in providing conditions for somatosensory evoked potential monitoring during scoliosis corrective surgery | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=6&volume=36&spage=779&epage=85.&date=2008&atitle=Comparison+between+sevoflurane/remifentanil+and+propofol/remifentanil+anaesthesia+in+providing+conditions+for+somatosensory+evoked+potential+monitoring+during+scoliosis+corrective+surgery.+ | en_HK |
dc.identifier.email | Hu, Y:yhud@hku.hk | en_HK |
dc.identifier.email | Irwin, MG:mgirwin@hku.hk | en_HK |
dc.identifier.authority | Hu, Y=rp00432 | en_HK |
dc.identifier.authority | Irwin, MG=rp00390 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1177/0310057X0803600605 | - |
dc.identifier.pmid | 19115644 | - |
dc.identifier.scopus | eid_2-s2.0-56649109628 | en_HK |
dc.identifier.hkuros | 159710 | en_HK |
dc.identifier.hkuros | 160834 | - |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-56649109628&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 36 | en_HK |
dc.identifier.issue | 6 | en_HK |
dc.identifier.spage | 779 | en_HK |
dc.identifier.epage | 785 | en_HK |
dc.identifier.eissn | 1448-0271 | - |
dc.identifier.isi | WOS:000261964000004 | - |
dc.publisher.place | Australia | en_HK |
dc.identifier.scopusauthorid | Fung, NY=36339436300 | en_HK |
dc.identifier.scopusauthorid | Hu, Y=7407116091 | en_HK |
dc.identifier.scopusauthorid | Irwin, MG=7202411076 | en_HK |
dc.identifier.scopusauthorid | Chow, BFM=36338944000 | en_HK |
dc.identifier.scopusauthorid | Yuen, MY=36342147800 | en_HK |
dc.identifier.issnl | 0310-057X | - |