File Download
There are no files associated with this item.
Supplementary
-
Citations:
- Appears in Collections:
Conference Paper: Bipolar radiofrequency with suction and light source for cellulite/circumference reduction and skin texture improvement
Title | Bipolar radiofrequency with suction and light source for cellulite/circumference reduction and skin texture improvement |
---|---|
Authors | |
Issue Date | 2009 |
Publisher | John Wiley & Sons, Inc. The Journal's web site is located at http://www3.interscience.wiley.com/cgi-bin/jhome/34073 |
Citation | The 29th Annual Scientific Conference of the American Society for Laser Surgery and Medicine (ASLMS 2009), National Harbor, MD., 3-5 April 2009. In Lasers in Surgery and Medicine, 2009, v. 41 suppl. 21, p. 84, abstract no. 523 How to Cite? |
Abstract | BACKGROUND: The bipolar radiofrequency with suction and light source device was cleared for use by the Food and Drug Administration for temporary reduction of cellulite. It has a reshaping effect on thighs, buttocks, abdomen and arms. This leads to temporary reduction in the circumference of the treated area. The purpose of this study is to evaluate its performance for temporary circumference reduction, as well as improvement of cellulite appearance. STUDY: 20 patients were recruited for 6 treatment sessions at weekly intervals. Patients were treated in two areas. The defined areas are both thighs, abdomen, buttocks, both arms and love handles. Subjects’ weight, photography, cellulite level, circumference measurements were taken before 1st, 4th, 6th treatment and at 4 week follow up. Patient satisfaction was rated. RESULTS: 14 subjects completed the course of treatment. 12 subjects treated their abdomen, 9 love handles, 4 buttocks and 3 thighs. The mean abdominal circumference went from 91.60 cm to 90.30 cm at treatment 6 and 90.84 at 4 weeks follow-up. Both are statistically significant with a p-value of 0.010 and 0.036 respectively. Decrease in love handles circumference at treatment 6 is also statistically significant with a p-value of 0.05. Mean circumference went from 93.1 cm to 92.2 cm. Other measurements are not statistically significant. One case of blistering was recorded which led to post-inflammatory hyperpigmentation. CONCLUSION: Temporary improvement in body contour can be achieved by a course of 6 treatments. Abdomen and love handles are the two areas that had the best outcome. |
Description | This journal suppl. entitled: Supplement: American Society for Laser Medicine and Surgery Twenty-Ninth Annual Conference April 1–5, 2009 |
Persistent Identifier | http://hdl.handle.net/10722/63915 |
ISSN | 2023 Impact Factor: 2.2 2023 SCImago Journal Rankings: 0.810 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Shek, SYN | - |
dc.contributor.author | Yeung, CK | - |
dc.contributor.author | Ho, SGY | - |
dc.contributor.author | Yu, CS | - |
dc.contributor.author | Chan, N | - |
dc.contributor.author | Chan, HH | - |
dc.date.accessioned | 2010-07-13T04:35:35Z | - |
dc.date.available | 2010-07-13T04:35:35Z | - |
dc.date.issued | 2009 | - |
dc.identifier.citation | The 29th Annual Scientific Conference of the American Society for Laser Surgery and Medicine (ASLMS 2009), National Harbor, MD., 3-5 April 2009. In Lasers in Surgery and Medicine, 2009, v. 41 suppl. 21, p. 84, abstract no. 523 | - |
dc.identifier.issn | 0196-8092 | - |
dc.identifier.uri | http://hdl.handle.net/10722/63915 | - |
dc.description | This journal suppl. entitled: Supplement: American Society for Laser Medicine and Surgery Twenty-Ninth Annual Conference April 1–5, 2009 | - |
dc.description.abstract | BACKGROUND: The bipolar radiofrequency with suction and light source device was cleared for use by the Food and Drug Administration for temporary reduction of cellulite. It has a reshaping effect on thighs, buttocks, abdomen and arms. This leads to temporary reduction in the circumference of the treated area. The purpose of this study is to evaluate its performance for temporary circumference reduction, as well as improvement of cellulite appearance. STUDY: 20 patients were recruited for 6 treatment sessions at weekly intervals. Patients were treated in two areas. The defined areas are both thighs, abdomen, buttocks, both arms and love handles. Subjects’ weight, photography, cellulite level, circumference measurements were taken before 1st, 4th, 6th treatment and at 4 week follow up. Patient satisfaction was rated. RESULTS: 14 subjects completed the course of treatment. 12 subjects treated their abdomen, 9 love handles, 4 buttocks and 3 thighs. The mean abdominal circumference went from 91.60 cm to 90.30 cm at treatment 6 and 90.84 at 4 weeks follow-up. Both are statistically significant with a p-value of 0.010 and 0.036 respectively. Decrease in love handles circumference at treatment 6 is also statistically significant with a p-value of 0.05. Mean circumference went from 93.1 cm to 92.2 cm. Other measurements are not statistically significant. One case of blistering was recorded which led to post-inflammatory hyperpigmentation. CONCLUSION: Temporary improvement in body contour can be achieved by a course of 6 treatments. Abdomen and love handles are the two areas that had the best outcome. | - |
dc.language | eng | - |
dc.publisher | John Wiley & Sons, Inc. The Journal's web site is located at http://www3.interscience.wiley.com/cgi-bin/jhome/34073 | - |
dc.relation.ispartof | Lasers in Surgery and Medicine | - |
dc.rights | Lasers in Surgery and Medicine. Copyright © John Wiley & Sons, Inc. | - |
dc.title | Bipolar radiofrequency with suction and light source for cellulite/circumference reduction and skin texture improvement | - |
dc.type | Conference_Paper | - |
dc.identifier.email | Yu, CS: carolsyu@hku.hk | - |
dc.identifier.authority | Yu, CS=rp00305 | - |
dc.identifier.doi | 10.1002/lsm.20783 | - |
dc.identifier.hkuros | 164708 | - |
dc.identifier.volume | 41 | - |
dc.identifier.issue | suppl. 21 | - |
dc.identifier.spage | 84, abstract no. 523 | - |
dc.identifier.epage | 84, abstract no. 523 | - |
dc.publisher.place | United States | - |
dc.identifier.issnl | 0196-8092 | - |