File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Influence of suture tension to the tearing characteristics of the soft tissues: An in vitro experiment

TitleInfluence of suture tension to the tearing characteristics of the soft tissues: An in vitro experiment
Authors
KeywordsFlap tension
Oral mucosa
Periodontal surgery
Suture materials
Tissue trauma
Issue Date2008
PublisherWiley-Blackwell Publishing, Inc.. The Journal's web site is located at http://www.blackwellpublishing.com/journals/CLR
Citation
Clinical Oral Implants Research, 2008, v. 19 n. 3, p. 314-319 How to Cite?
AbstractObjectives: To evaluate the influence of flap tension on the tearing characteristics of mucosal tissue samples in relation to various suture and needle characteristics. Material and methods: Lining and masticatory mucosal tissue samples obtained from pig jaws were prepared for in vitro testing. Tension tearing diagrams of 60 experiments were traced for 3-0, 5-0 and 7-0 sutures with applied forces up to 20 N. In the second part, the same experiments were repeated with 100 diagrams to test the influence of needle characteristics with 5-0 and 6-0 sutures using only gingival tissue samples. Results: 3-0 sutures mainly lead to tissue breakage at an average of 13.4 N. In contrast, 7-0 sutures only resulted in breakage of the thread at a mean applied force of 3.7 N. With 5-0 sutures, both events occurred at random at a mean force of 14.6 N. Irrespective of the needle characteristics, the mean breaking force for gingival samples with 5-0 and 6-0 sutures was approximately 10 N. Conclusions: Tissue trauma may be reduced by choosing finer suture diameters, because thinner (6-0, 7-0) sutures lead to thread breakage rather than tissue breakage. © 2008 Blackwell Munksgaard.
Persistent Identifierhttp://hdl.handle.net/10722/66645
ISSN
2023 Impact Factor: 4.8
2023 SCImago Journal Rankings: 1.865
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorBurkhardt, Ren_HK
dc.contributor.authorPreiss, Aen_HK
dc.contributor.authorJoss, Aen_HK
dc.contributor.authorLang, NPen_HK
dc.date.accessioned2010-09-06T05:48:07Z-
dc.date.available2010-09-06T05:48:07Z-
dc.date.issued2008en_HK
dc.identifier.citationClinical Oral Implants Research, 2008, v. 19 n. 3, p. 314-319en_HK
dc.identifier.issn0905-7161en_HK
dc.identifier.urihttp://hdl.handle.net/10722/66645-
dc.description.abstractObjectives: To evaluate the influence of flap tension on the tearing characteristics of mucosal tissue samples in relation to various suture and needle characteristics. Material and methods: Lining and masticatory mucosal tissue samples obtained from pig jaws were prepared for in vitro testing. Tension tearing diagrams of 60 experiments were traced for 3-0, 5-0 and 7-0 sutures with applied forces up to 20 N. In the second part, the same experiments were repeated with 100 diagrams to test the influence of needle characteristics with 5-0 and 6-0 sutures using only gingival tissue samples. Results: 3-0 sutures mainly lead to tissue breakage at an average of 13.4 N. In contrast, 7-0 sutures only resulted in breakage of the thread at a mean applied force of 3.7 N. With 5-0 sutures, both events occurred at random at a mean force of 14.6 N. Irrespective of the needle characteristics, the mean breaking force for gingival samples with 5-0 and 6-0 sutures was approximately 10 N. Conclusions: Tissue trauma may be reduced by choosing finer suture diameters, because thinner (6-0, 7-0) sutures lead to thread breakage rather than tissue breakage. © 2008 Blackwell Munksgaard.en_HK
dc.languageengen_HK
dc.publisherWiley-Blackwell Publishing, Inc.. The Journal's web site is located at http://www.blackwellpublishing.com/journals/CLRen_HK
dc.relation.ispartofClinical Oral Implants Researchen_HK
dc.subjectFlap tension-
dc.subjectOral mucosa-
dc.subjectPeriodontal surgery-
dc.subjectSuture materials-
dc.subjectTissue trauma-
dc.subject.meshAnimalsen_HK
dc.subject.meshDental Stress Analysisen_HK
dc.subject.meshElasticityen_HK
dc.subject.meshMaterials Testingen_HK
dc.subject.meshMouth Mucosa - anatomy & histology - injuries - physiologyen_HK
dc.subject.meshNeedlesen_HK
dc.subject.meshPilot Projectsen_HK
dc.subject.meshSurgical Wound Dehiscence - prevention & controlen_HK
dc.subject.meshSutures - adverse effectsen_HK
dc.subject.meshSwineen_HK
dc.subject.meshTensile Strengthen_HK
dc.titleInfluence of suture tension to the tearing characteristics of the soft tissues: An in vitro experimenten_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0905-7161&volume=19&spage=314&epage=9&date=2008&atitle=Influence+of+suture+tension+to+the+tearing+characteristics+of+the+soft+tissues:+an+in+vitro+experimenten_HK
dc.identifier.emailLang, NP:nplang@hkucc.hku.hken_HK
dc.identifier.authorityLang, NP=rp00031en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1111/j.1600-0501.2007.01352.xen_HK
dc.identifier.pmid18177431-
dc.identifier.scopuseid_2-s2.0-38849118426en_HK
dc.identifier.hkuros153615en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-38849118426&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume19en_HK
dc.identifier.issue3en_HK
dc.identifier.spage314en_HK
dc.identifier.epage319en_HK
dc.identifier.isiWOS:000252711700015-
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridBurkhardt, R=7005197647en_HK
dc.identifier.scopusauthoridPreiss, A=7005302559en_HK
dc.identifier.scopusauthoridJoss, A=7005904584en_HK
dc.identifier.scopusauthoridLang, NP=7201577367en_HK
dc.identifier.citeulike2312108-
dc.identifier.issnl0905-7161-

Export via OAI-PMH Interface in XML Formats