File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/S0956-5663(02)00030-1
- Scopus: eid_2-s2.0-0036015962
- PMID: 12052353
- WOS: WOS:000176900000006
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Immunosensor for the differentiation and detection of Salmonella species based on a quartz crystal microbalance
Title | Immunosensor for the differentiation and detection of Salmonella species based on a quartz crystal microbalance |
---|---|
Authors | |
Keywords | Immunosensors Microbalance Monoclonal antibodies Polyethyleneimine Salmonella |
Issue Date | 2002 |
Publisher | Elsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/bios |
Citation | Biosensors And Bioelectronics, 2002, v. 17 n. 8, p. 676-684 How to Cite? |
Abstract | Immunosensors based on the microgravimetric quartz crystal microbalance (QCM) technique have been developed for the detection of Salmonella species from serogroups A, B and D. Salmonella serogroup-specific murine monoclonal antibodies, respectively, raised against these serogroups were immobilized onto the silver electrodes of piezoelectric (PZ) crystals by cross-linkage via glutaraldehyde (GA) to the electrode surfaces pre-coated with thin polyethyleneimine (PEI) layer. The specific immunosensors developed gave responses in linear ranges from 10 5 to 5×10 8 cells per ml with no significant interference from other strains of Salmonella and Escherichia coli up to 10 8 cells per ml. They showed good repeatability and excellent linear range, achieving detection limits down to 10 4 cells per ml with ability to distinguish different strains of Salmonella. These biosensors exhibited an exquisite specificity evidenced by their ability to discriminate antigens, the structures of which differ only by the isomeric form of di-deoxyhexose. The antibody-modified crystals showed no loss in activity over 4 days under storage at 4°C. © 2002 Elsevier Science B.V. All rights reserved. |
Persistent Identifier | http://hdl.handle.net/10722/68981 |
ISSN | 2023 Impact Factor: 10.7 2023 SCImago Journal Rankings: 2.052 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wong, YY | en_HK |
dc.contributor.author | Ng, SP | en_HK |
dc.contributor.author | Ng, MH | en_HK |
dc.contributor.author | Si, SH | en_HK |
dc.contributor.author | Yao, SZ | en_HK |
dc.contributor.author | Fung, YS | en_HK |
dc.date.accessioned | 2010-09-06T06:09:28Z | - |
dc.date.available | 2010-09-06T06:09:28Z | - |
dc.date.issued | 2002 | en_HK |
dc.identifier.citation | Biosensors And Bioelectronics, 2002, v. 17 n. 8, p. 676-684 | en_HK |
dc.identifier.issn | 0956-5663 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/68981 | - |
dc.description.abstract | Immunosensors based on the microgravimetric quartz crystal microbalance (QCM) technique have been developed for the detection of Salmonella species from serogroups A, B and D. Salmonella serogroup-specific murine monoclonal antibodies, respectively, raised against these serogroups were immobilized onto the silver electrodes of piezoelectric (PZ) crystals by cross-linkage via glutaraldehyde (GA) to the electrode surfaces pre-coated with thin polyethyleneimine (PEI) layer. The specific immunosensors developed gave responses in linear ranges from 10 5 to 5×10 8 cells per ml with no significant interference from other strains of Salmonella and Escherichia coli up to 10 8 cells per ml. They showed good repeatability and excellent linear range, achieving detection limits down to 10 4 cells per ml with ability to distinguish different strains of Salmonella. These biosensors exhibited an exquisite specificity evidenced by their ability to discriminate antigens, the structures of which differ only by the isomeric form of di-deoxyhexose. The antibody-modified crystals showed no loss in activity over 4 days under storage at 4°C. © 2002 Elsevier Science B.V. All rights reserved. | en_HK |
dc.language | eng | en_HK |
dc.publisher | Elsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/bios | en_HK |
dc.relation.ispartof | Biosensors and Bioelectronics | en_HK |
dc.rights | Biosensors and Bioelectronics. Copyright © Elsevier BV. | en_HK |
dc.subject | Immunosensors | en_HK |
dc.subject | Microbalance | en_HK |
dc.subject | Monoclonal antibodies | en_HK |
dc.subject | Polyethyleneimine | en_HK |
dc.subject | Salmonella | en_HK |
dc.title | Immunosensor for the differentiation and detection of Salmonella species based on a quartz crystal microbalance | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0956-5663&volume=17&spage=676&epage=684&date=2002&atitle=Immunosensor+for+the+differentiation+and+detection+of+Salmonella+species+based+on+a+quartz+crystal+microbalance | en_HK |
dc.identifier.email | Fung, YS:ysfung@hku.hk | en_HK |
dc.identifier.authority | Fung, YS=rp00697 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/S0956-5663(02)00030-1 | en_HK |
dc.identifier.pmid | 12052353 | - |
dc.identifier.scopus | eid_2-s2.0-0036015962 | en_HK |
dc.identifier.hkuros | 68494 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-0036015962&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 17 | en_HK |
dc.identifier.issue | 8 | en_HK |
dc.identifier.spage | 676 | en_HK |
dc.identifier.epage | 684 | en_HK |
dc.identifier.isi | WOS:000176900000006 | - |
dc.publisher.place | Netherlands | en_HK |
dc.identifier.scopusauthorid | Wong, YY=7403041805 | en_HK |
dc.identifier.scopusauthorid | Ng, SP=8862966400 | en_HK |
dc.identifier.scopusauthorid | Ng, MH=7202076421 | en_HK |
dc.identifier.scopusauthorid | Si, SH=7006049232 | en_HK |
dc.identifier.scopusauthorid | Yao, SZ=35619833600 | en_HK |
dc.identifier.scopusauthorid | Fung, YS=13309754700 | en_HK |
dc.identifier.issnl | 0956-5663 | - |