File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/S0040-6090(98)00819-0
- Scopus: eid_2-s2.0-0032204829
- WOS: WOS:000077337100038
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: New sol-gel oxygen sensor based on luminescence cyclometallated platinum complexes
Title | New sol-gel oxygen sensor based on luminescence cyclometallated platinum complexes |
---|---|
Authors | |
Keywords | Condensation Luminescence Platinum Sensor |
Issue Date | 1998 |
Publisher | Elsevier S.A.. The Journal's web site is located at http://www.elsevier.com/locate/tsf |
Citation | Thin Solid Films, 1998, v. 333 n. 1-2, p. 224-227 How to Cite? |
Abstract | A triethoxysilyl-functionalized cyclometallated platinum(II) complex Pt(MeOPhC∧N∧N)X (where MeOPhCN∧N=C-anion of 3-phenyl-5-p-methoxylphenyl-2,2′-bipyridine and X=NH 2(CH 2) 3Si(OCH 2CH 3) 3) was homogeneously incorporated into sol-gel glass by cocondensation with Si(OCH 2CH 3) 4. The resultant luminescence shows a rapid and sensitive response to oxygen gas: 58% luminescence is quenched in ca. 10 s when switching from dinitrogen to dioxygen. © 1998 Elsevier Science S.A. All rights reserved. |
Persistent Identifier | http://hdl.handle.net/10722/69315 |
ISSN | 2023 Impact Factor: 2.0 2023 SCImago Journal Rankings: 0.400 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ma, YG | en_HK |
dc.contributor.author | Cheung, TC | en_HK |
dc.contributor.author | Che, CM | en_HK |
dc.contributor.author | Shen, JC | en_HK |
dc.date.accessioned | 2010-09-06T06:12:31Z | - |
dc.date.available | 2010-09-06T06:12:31Z | - |
dc.date.issued | 1998 | en_HK |
dc.identifier.citation | Thin Solid Films, 1998, v. 333 n. 1-2, p. 224-227 | en_HK |
dc.identifier.issn | 0040-6090 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/69315 | - |
dc.description.abstract | A triethoxysilyl-functionalized cyclometallated platinum(II) complex Pt(MeOPhC∧N∧N)X (where MeOPhCN∧N=C-anion of 3-phenyl-5-p-methoxylphenyl-2,2′-bipyridine and X=NH 2(CH 2) 3Si(OCH 2CH 3) 3) was homogeneously incorporated into sol-gel glass by cocondensation with Si(OCH 2CH 3) 4. The resultant luminescence shows a rapid and sensitive response to oxygen gas: 58% luminescence is quenched in ca. 10 s when switching from dinitrogen to dioxygen. © 1998 Elsevier Science S.A. All rights reserved. | en_HK |
dc.language | eng | en_HK |
dc.publisher | Elsevier S.A.. The Journal's web site is located at http://www.elsevier.com/locate/tsf | en_HK |
dc.relation.ispartof | Thin Solid Films | en_HK |
dc.subject | Condensation | en_HK |
dc.subject | Luminescence | en_HK |
dc.subject | Platinum | en_HK |
dc.subject | Sensor | en_HK |
dc.title | New sol-gel oxygen sensor based on luminescence cyclometallated platinum complexes | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0040-6090&volume=333&spage=224&epage=227&date=1998&atitle=New+sol-gel+oxygen+sensor+based+on+luminescence+cyclometallated+platinum+complexes | en_HK |
dc.identifier.email | Che, CM:cmche@hku.hk | en_HK |
dc.identifier.authority | Che, CM=rp00670 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/S0040-6090(98)00819-0 | - |
dc.identifier.scopus | eid_2-s2.0-0032204829 | en_HK |
dc.identifier.hkuros | 40275 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-0032204829&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 333 | en_HK |
dc.identifier.issue | 1-2 | en_HK |
dc.identifier.spage | 224 | en_HK |
dc.identifier.epage | 227 | en_HK |
dc.identifier.isi | WOS:000077337100038 | - |
dc.publisher.place | Switzerland | en_HK |
dc.identifier.scopusauthorid | Ma, YG=37080011300 | en_HK |
dc.identifier.scopusauthorid | Cheung, TC=36847497800 | en_HK |
dc.identifier.scopusauthorid | Che, CM=7102442791 | en_HK |
dc.identifier.scopusauthorid | Shen, JC=36050315700 | en_HK |
dc.identifier.issnl | 0040-6090 | - |