AbstractExperimental tests were carried out on a series of ferroelectric specimens (PZT-5) with cracks of different inclined angles, subjected to alternate electric fields. The cracks were found to deviate from their original plane for all inclined angles. The dominant factor of electric fatigue was found to be the ratio of the applied electric field to the coercive field. © 2003 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Persistent Identifierhttp://hdl.handle.net/10722/75782
ISSN
2023 Impact Factor: 5.3
2023 SCImago Journal Rankings: 1.738
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorLee, KLen_HK
dc.contributor.authorSoh, AKen_HK
dc.contributor.authorHe, PFen_HK
dc.date.accessioned2010-09-06T07:14:30Z-
dc.date.available2010-09-06T07:14:30Z-
dc.date.issued2003en_HK
dc.identifier.citationScripta Materialia, 2003, v. 49 n. 9, p. 849-854en_HK
dc.identifier.issn1359-6462en_HK
dc.identifier.urihttp://hdl.handle.net/10722/75782-
dc.description.abstractExperimental tests were carried out on a series of ferroelectric specimens (PZT-5) with cracks of different inclined angles, subjected to alternate electric fields. The cracks were found to deviate from their original plane for all inclined angles. The dominant factor of electric fatigue was found to be the ratio of the applied electric field to the coercive field. © 2003 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.en_HK
dc.languageengen_HK
dc.publisherPergamon. The Journal's web site is located at http://www.elsevier.com/locate/scriptamaten_HK
dc.relation.ispartofScripta Materialiaen_HK
dc.subjectCrack deflectionen_HK
dc.subjectFatigueen_HK
dc.subjectFerroelectric ceramicen_HK
dc.titleFatigue failure of ferroelectric ceramics subjected to cyclic inclined electric loadingen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1359-6462&volume=49&issue=9&spage=849&epage=854&date=2003&atitle=Fatigue+failure+of+ferroelectric+ceramics+subjected+to+cyclic+inclined+electric+loadingen_HK
dc.identifier.emailSoh, AK:aksoh@hkucc.hku.hken_HK
dc.identifier.authoritySoh, AK=rp00170en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/S1359-6462(03)00445-7en_HK
dc.identifier.scopuseid_2-s2.0-0042029526en_HK
dc.identifier.hkuros88987en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0042029526&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume49en_HK
dc.identifier.issue9en_HK
dc.identifier.spage849en_HK
dc.identifier.epage854en_HK
dc.identifier.isiWOS:000185038400007-
dc.publisher.placeUnited Kingdomen_HK
dc.identifier.scopusauthoridLee, KL=7501505110en_HK
dc.identifier.scopusauthoridSoh, AK=7006795203en_HK
dc.identifier.scopusauthoridHe, PF=7202088710en_HK
dc.identifier.issnl1359-6462-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats