Article: Inability to start hemodialysis after a smooth temporary hemodialysis catheter insertion procedure

TitleInability to start hemodialysis after a smooth temporary hemodialysis catheter insertion procedure
Authors
KeywordsCentral venous catheter
Hemodialysis
Internal thoracic vein
Venography
Issue Date2007
PublisherBlackwell Publishing, Inc. The Journal's web site is located at http://www.blackwellpublishing.com/journals/HDI
Citation
Hemodialysis International, 2007, v. 11 n. 1, p. 32-34 How to Cite?
AbstractCannulation of the central vein for placement of the temporary dual-lumen catheter for hemodialysis can usually be safely and reliably performed under ultrasonographic guidance. Here, we report a case of aberrant catheter entry into the internal thoracic vein during an apparently smooth procedure. The value of sonographic guidance, together with fluoroscopy with or without venography, will be discussed. © 2007 International Society for Hemodialysis.
Persistent Identifierhttp://hdl.handle.net/10722/78219
ISSN
2023 Impact Factor: 1.2
2023 SCImago Journal Rankings: 0.425
References

 

DC FieldValueLanguage
dc.contributor.authorTang, SCWen_HK
dc.contributor.authorLee, Ren_HK
dc.contributor.authorTse, KCen_HK
dc.contributor.authorLai, ASHen_HK
dc.contributor.authorLai, KNen_HK
dc.date.accessioned2010-09-06T07:40:28Z-
dc.date.available2010-09-06T07:40:28Z-
dc.date.issued2007en_HK
dc.identifier.citationHemodialysis International, 2007, v. 11 n. 1, p. 32-34en_HK
dc.identifier.issn1492-7535en_HK
dc.identifier.urihttp://hdl.handle.net/10722/78219-
dc.description.abstractCannulation of the central vein for placement of the temporary dual-lumen catheter for hemodialysis can usually be safely and reliably performed under ultrasonographic guidance. Here, we report a case of aberrant catheter entry into the internal thoracic vein during an apparently smooth procedure. The value of sonographic guidance, together with fluoroscopy with or without venography, will be discussed. © 2007 International Society for Hemodialysis.en_HK
dc.languageengen_HK
dc.publisherBlackwell Publishing, Inc. The Journal's web site is located at http://www.blackwellpublishing.com/journals/HDIen_HK
dc.relation.ispartofHemodialysis Internationalen_HK
dc.subjectCentral venous catheteren_HK
dc.subjectHemodialysisen_HK
dc.subjectInternal thoracic veinen_HK
dc.subjectVenographyen_HK
dc.subject.meshAgeden_HK
dc.subject.meshCatheterization, Central Venous - methodsen_HK
dc.subject.meshEndosonographyen_HK
dc.subject.meshFemaleen_HK
dc.subject.meshFluoroscopyen_HK
dc.subject.meshHumansen_HK
dc.subject.meshPhlebographyen_HK
dc.subject.meshRenal Dialysis - methodsen_HK
dc.subject.meshVeins - ultrasonographyen_HK
dc.titleInability to start hemodialysis after a smooth temporary hemodialysis catheter insertion procedureen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1492-7535&volume=11&spage=32&epage=34&date=2007&atitle=Inability+to+start+hemodialysis+after+a+smooth+temporary+hemodialysis+catheter+insertion+procedureen_HK
dc.identifier.emailTang, SCW: scwtang@hku.hken_HK
dc.identifier.emailLai, KN: knlai@hku.hken_HK
dc.identifier.authorityTang, SCW=rp00480en_HK
dc.identifier.authorityLai, KN=rp00324en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1111/j.1542-4758.2007.00149.xen_HK
dc.identifier.pmid17257352-
dc.identifier.scopuseid_2-s2.0-33846386173en_HK
dc.identifier.hkuros134585en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-33846386173&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume11en_HK
dc.identifier.issue1en_HK
dc.identifier.spage32en_HK
dc.identifier.epage34en_HK
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridTang, SCW=7403437082en_HK
dc.identifier.scopusauthoridLee, R=55473408700en_HK
dc.identifier.scopusauthoridTse, KC=7102609864en_HK
dc.identifier.scopusauthoridLai, ASH=8711668800en_HK
dc.identifier.scopusauthoridLai, KN=7402135706en_HK
dc.identifier.citeulike1056412-
dc.identifier.issnl1492-7535-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats