File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Cementless total hip arthroplasty in young Chinese patients: A comparison of 2 different prostheses

TitleCementless total hip arthroplasty in young Chinese patients: A comparison of 2 different prostheses
Authors
KeywordsCementless
Chinese
Total hip arthroplasty
Young
Issue Date2001
PublisherChurchill Livingstone. The Journal's web site is located at http://www.elsevier.com/locate/arthroplastyjournal
Citation
Journal Of Arthroplasty, 2001, v. 16 n. 7, p. 863-870 How to Cite?
AbstractSixty-one primary cementless total hip arthroplasties were performed in 45 Chinese patients <40 years old. There were 27 Anatomic Medullary Locking (AML, Depuy, Warsaw, IN) prostheses and 34 Porous Coated Anatomic (PCA, Howmedica, Rutherford, NJ) prostheses. The average follow-up was 7.6 years (range, 3-11 years). Ten hips (16%) were reoperated; the reason was polyethylene wear with or without osteolysis in 7 hips. Osteolytic lesion was present in 34 hips (56%). The cumulative successful rate at 10 years was 67% using reoperation for any reason as the endpoint. The cumulative successful rate was 98%, however, if revision for aseptic loosening was used as the endpoint. The 2 prostheses did not show significant differences in most parameters except that the PCA hips had significantly more acetabular loosening (P = .02) and periprosthetic osteolysis (P = .01).
Persistent Identifierhttp://hdl.handle.net/10722/79668
ISSN
2023 Impact Factor: 3.4
2023 SCImago Journal Rankings: 1.849
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorChiu, KYen_HK
dc.contributor.authorTang, WMen_HK
dc.contributor.authorNg, TPen_HK
dc.contributor.authorPoon, KCen_HK
dc.contributor.authorHo, WYen_HK
dc.contributor.authorLee, KMen_HK
dc.date.accessioned2010-09-06T07:57:14Z-
dc.date.available2010-09-06T07:57:14Z-
dc.date.issued2001en_HK
dc.identifier.citationJournal Of Arthroplasty, 2001, v. 16 n. 7, p. 863-870en_HK
dc.identifier.issn0883-5403en_HK
dc.identifier.urihttp://hdl.handle.net/10722/79668-
dc.description.abstractSixty-one primary cementless total hip arthroplasties were performed in 45 Chinese patients <40 years old. There were 27 Anatomic Medullary Locking (AML, Depuy, Warsaw, IN) prostheses and 34 Porous Coated Anatomic (PCA, Howmedica, Rutherford, NJ) prostheses. The average follow-up was 7.6 years (range, 3-11 years). Ten hips (16%) were reoperated; the reason was polyethylene wear with or without osteolysis in 7 hips. Osteolytic lesion was present in 34 hips (56%). The cumulative successful rate at 10 years was 67% using reoperation for any reason as the endpoint. The cumulative successful rate was 98%, however, if revision for aseptic loosening was used as the endpoint. The 2 prostheses did not show significant differences in most parameters except that the PCA hips had significantly more acetabular loosening (P = .02) and periprosthetic osteolysis (P = .01).en_HK
dc.languageengen_HK
dc.publisherChurchill Livingstone. The Journal's web site is located at http://www.elsevier.com/locate/arthroplastyjournalen_HK
dc.relation.ispartofJournal of Arthroplastyen_HK
dc.subjectCementlessen_HK
dc.subjectChineseen_HK
dc.subjectTotal hip arthroplastyen_HK
dc.subjectYoungen_HK
dc.titleCementless total hip arthroplasty in young Chinese patients: A comparison of 2 different prosthesesen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0883-5403&volume=&spage=&epage=&date=2002&atitle=Cementless+total+hip+arthroplasty+in+young+Chinese+patients+-+a+comparison+of+2+different+prosthesesen_HK
dc.identifier.emailChiu, KY:pkychiu@hkucc.hku.hken_HK
dc.identifier.authorityChiu, KY=rp00379en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1054/arth.2001.25505en_HK
dc.identifier.pmid11607902-
dc.identifier.scopuseid_2-s2.0-0034791156en_HK
dc.identifier.hkuros65204en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0034791156&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume16en_HK
dc.identifier.issue7en_HK
dc.identifier.spage863en_HK
dc.identifier.epage870en_HK
dc.identifier.isiWOS:000171577100008-
dc.publisher.placeUnited Statesen_HK
dc.identifier.scopusauthoridChiu, KY=7202988127en_HK
dc.identifier.scopusauthoridTang, WM=7403430820en_HK
dc.identifier.scopusauthoridNg, TP=24438193400en_HK
dc.identifier.scopusauthoridPoon, KC=36776891500en_HK
dc.identifier.scopusauthoridHo, WY=36855638100en_HK
dc.identifier.scopusauthoridLee, KM=38163183100en_HK
dc.identifier.issnl0883-5403-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats