AbstractThis study examined the clinical utility of measuring the external ear resonance (EER) amplitude peak as a screening test for detecting hearing loss in children with otitis media with effusion (OME). The peak EER amplitude and frequeney of 180 ears in 100 children at risk of hearing loss related to OME was recorded. A relationship was found to exist between peak EER amplitude and hearing level, in particular at low frequencies, or the pure tone average (500, 1000 and 2000 Hz). However, the correlation was not strong and a wide scatter of results was apparent. Using a criterion of >15 dB HL three-frequeney average for failure, the ears were divided into normal hearing and hearing loss groups. The two groups differed significantly with regard to peak EER amplitude but the sensitivity and specificity levels of the EER test suggest it is of limited benefit as an indication of OME-related hearing loss in screening situations. An alternate hearing loss criterion, ≤25 dB HL, did not give improved predictive levels.
Persistent Identifierhttp://hdl.handle.net/10722/82560
ISSN
References

 

DC FieldValueLanguage
dc.contributor.authorStrachan, Den_HK
dc.contributor.authorMcPherson, Ben_HK
dc.contributor.authorSmyth, Ven_HK
dc.contributor.authorScott, Jen_HK
dc.date.accessioned2010-09-06T08:30:45Z-
dc.date.available2010-09-06T08:30:45Z-
dc.date.issued1996en_HK
dc.identifier.citationJournal Of Audiological Medicine, 1996, v. 5 n. 2, p. 73-82en_HK
dc.identifier.issn0963-7133en_HK
dc.identifier.urihttp://hdl.handle.net/10722/82560-
dc.description.abstractThis study examined the clinical utility of measuring the external ear resonance (EER) amplitude peak as a screening test for detecting hearing loss in children with otitis media with effusion (OME). The peak EER amplitude and frequeney of 180 ears in 100 children at risk of hearing loss related to OME was recorded. A relationship was found to exist between peak EER amplitude and hearing level, in particular at low frequencies, or the pure tone average (500, 1000 and 2000 Hz). However, the correlation was not strong and a wide scatter of results was apparent. Using a criterion of >15 dB HL three-frequeney average for failure, the ears were divided into normal hearing and hearing loss groups. The two groups differed significantly with regard to peak EER amplitude but the sensitivity and specificity levels of the EER test suggest it is of limited benefit as an indication of OME-related hearing loss in screening situations. An alternate hearing loss criterion, ≤25 dB HL, did not give improved predictive levels.en_HK
dc.languageengen_HK
dc.publisherWhurr Publishers Ltd. The Journal's web site is located at http://www.whurr.co.uk/JAM/EdIntro.htmlen_HK
dc.relation.ispartofJournal of Audiological Medicineen_HK
dc.subjectexternal ear resonanceen_HK
dc.subjecthearing screeningen_HK
dc.subjectotitis media with effusionen_HK
dc.subjectreal ear measuresen_HK
dc.titleHearing screening for children with otitis media with effusion using external ear resonanceen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0963-7133&volume=5&spage=73&epage=82&date=1996&atitle=Hearing+screening+for+children+with+otitis+media+with+effusion+using+external+ear+resonanceen_HK
dc.identifier.emailMcPherson, B: dbmcpher@hkucc.hku.hken_HK
dc.identifier.authorityMcPherson, B=rp00937en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.scopuseid_2-s2.0-0029785535en_HK
dc.identifier.hkuros25538en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0029785535&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume5en_HK
dc.identifier.issue2en_HK
dc.identifier.spage73en_HK
dc.identifier.epage82en_HK
dc.publisher.placeUnited Kingdomen_HK
dc.identifier.scopusauthoridStrachan, D=7103288984en_HK
dc.identifier.scopusauthoridMcPherson, B=7006800770en_HK
dc.identifier.scopusauthoridSmyth, V=7003542460en_HK
dc.identifier.scopusauthoridScott, J=35246713800en_HK
dc.identifier.issnl0963-7133-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats