File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/S1570-0232(03)00489-6
- Scopus: eid_2-s2.0-0242495502
- PMID: 14630151
- WOS: WOS:000186844600013
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Capillary electrophoresis-based immunoassay
Title | Capillary electrophoresis-based immunoassay |
---|---|
Authors | |
Keywords | Capillary electrophoresis Immunoassays Review |
Issue Date | 2003 |
Publisher | Elsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/jchromb |
Citation | Journal Of Chromatography B: Analytical Technologies In The Biomedical And Life Sciences, 2003, v. 797 n. 1-2, p. 217-228 How to Cite? |
Abstract | Capillary electrophoresis-based immunoassay (CEIA) is a developing analytical technique with a number of advantages over conventional immunoassay, such as reduced sample consumption, simpler procedure, easy simultaneous determination of multiple analytes, and short analysis time. However, there are still a number of technical issues that researchers on CEIA have to solve before the assay can be more widely used. These issues include method to improve the concentration sensitivity of the assay, requirement for robust separation strategy for different analytes, and method to increase the throughput of the assay. The approaches to solve these issues are reviewed. Several studies have been devoted to develop general separation strategies for CEIA, and to enhance the sensitivity of detection. The recent development of microchip-based CEIA is encouraging and is likely to address more drawbacks of CEIA, particularly on the throughput issue. © 2003 Elsevier B.V. All rights reserved. |
Persistent Identifier | http://hdl.handle.net/10722/87370 |
ISSN | 2023 Impact Factor: 2.8 2023 SCImago Journal Rankings: 0.539 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yeung, WSB | en_HK |
dc.contributor.author | Luo, GA | en_HK |
dc.contributor.author | Wang, QG | en_HK |
dc.contributor.author | Ou, JP | en_HK |
dc.date.accessioned | 2010-09-06T09:28:47Z | - |
dc.date.available | 2010-09-06T09:28:47Z | - |
dc.date.issued | 2003 | en_HK |
dc.identifier.citation | Journal Of Chromatography B: Analytical Technologies In The Biomedical And Life Sciences, 2003, v. 797 n. 1-2, p. 217-228 | en_HK |
dc.identifier.issn | 1570-0232 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/87370 | - |
dc.description.abstract | Capillary electrophoresis-based immunoassay (CEIA) is a developing analytical technique with a number of advantages over conventional immunoassay, such as reduced sample consumption, simpler procedure, easy simultaneous determination of multiple analytes, and short analysis time. However, there are still a number of technical issues that researchers on CEIA have to solve before the assay can be more widely used. These issues include method to improve the concentration sensitivity of the assay, requirement for robust separation strategy for different analytes, and method to increase the throughput of the assay. The approaches to solve these issues are reviewed. Several studies have been devoted to develop general separation strategies for CEIA, and to enhance the sensitivity of detection. The recent development of microchip-based CEIA is encouraging and is likely to address more drawbacks of CEIA, particularly on the throughput issue. © 2003 Elsevier B.V. All rights reserved. | en_HK |
dc.language | eng | en_HK |
dc.publisher | Elsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/jchromb | en_HK |
dc.relation.ispartof | Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences | en_HK |
dc.rights | Journal of Chromatography B, Analytical Technologies in the Biomedical and Life Sciences. Copyright © Elsevier BV. | en_HK |
dc.subject | Capillary electrophoresis | en_HK |
dc.subject | Immunoassays | en_HK |
dc.subject | Review | en_HK |
dc.title | Capillary electrophoresis-based immunoassay | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1570-0232&volume=797&spage=217&epage=228&date=2003&atitle=Capillary+electrophoresis-based+immunoassay | en_HK |
dc.identifier.email | Yeung, WSB:wsbyeung@hkucc.hku.hk | en_HK |
dc.identifier.authority | Yeung, WSB=rp00331 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/S1570-0232(03)00489-6 | en_HK |
dc.identifier.pmid | 14630151 | - |
dc.identifier.scopus | eid_2-s2.0-0242495502 | en_HK |
dc.identifier.hkuros | 87485 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-0242495502&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 797 | en_HK |
dc.identifier.issue | 1-2 | en_HK |
dc.identifier.spage | 217 | en_HK |
dc.identifier.epage | 228 | en_HK |
dc.identifier.isi | WOS:000186844600013 | - |
dc.publisher.place | Netherlands | en_HK |
dc.identifier.scopusauthorid | Yeung, WSB=7102370745 | en_HK |
dc.identifier.scopusauthorid | Luo, GA=7401536462 | en_HK |
dc.identifier.scopusauthorid | Wang, QG=7406915351 | en_HK |
dc.identifier.scopusauthorid | Ou, JP=7202845297 | en_HK |
dc.identifier.issnl | 1570-0232 | - |