Article: A fully automated radon exposure chamber

TitleA fully automated radon exposure chamber
Authors
Issue Date1994
PublisherElsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/nima
Citation
Nuclear Inst. And Methods In Physics Research, A, 1994, v. 350 n. 3, p. 566-571 How to Cite?
AbstractA fully automated radon exposure chamber is described. The chamber is made of stainless steel and has a volume of 1.46 m3. The chamber allows 222Rn, 220Rn or both to be injected from the bottom pipe-lines into the chamber in a 100% flow-through mode, 100% recirculate mode or flow-through/recirculate mode. Either atmospheric aerosol or monodisperse aerosol from aerosol generator can be injected into the chamber. The radon concentration; radon daughter concentration; unattached fraction of radon daughters; aerosol size distribution and activity size distribution of radon daughters in aerosols are continuously monitored by computers and feedback signals are used to maintain the specified condition. Though the chamber may be small when compared to walk-in type exposure room, it has the advantage of fast response to changes in the chamber condition and yet is large enough to preclude perturbations due to sampling or other activities. © 1994.
Persistent Identifierhttp://hdl.handle.net/10722/90456
ISSN
2023 Impact Factor: 1.5
2023 SCImago Journal Rankings: 0.514
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorLeung, JKCen_HK
dc.contributor.authorJia, Den_HK
dc.contributor.authorTso, MyWen_HK
dc.date.accessioned2010-09-06T10:10:51Z-
dc.date.available2010-09-06T10:10:51Z-
dc.date.issued1994en_HK
dc.identifier.citationNuclear Inst. And Methods In Physics Research, A, 1994, v. 350 n. 3, p. 566-571en_HK
dc.identifier.issn0168-9002en_HK
dc.identifier.urihttp://hdl.handle.net/10722/90456-
dc.description.abstractA fully automated radon exposure chamber is described. The chamber is made of stainless steel and has a volume of 1.46 m3. The chamber allows 222Rn, 220Rn or both to be injected from the bottom pipe-lines into the chamber in a 100% flow-through mode, 100% recirculate mode or flow-through/recirculate mode. Either atmospheric aerosol or monodisperse aerosol from aerosol generator can be injected into the chamber. The radon concentration; radon daughter concentration; unattached fraction of radon daughters; aerosol size distribution and activity size distribution of radon daughters in aerosols are continuously monitored by computers and feedback signals are used to maintain the specified condition. Though the chamber may be small when compared to walk-in type exposure room, it has the advantage of fast response to changes in the chamber condition and yet is large enough to preclude perturbations due to sampling or other activities. © 1994.en_HK
dc.languageengen_HK
dc.publisherElsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/nimaen_HK
dc.relation.ispartofNuclear Inst. and Methods in Physics Research, Aen_HK
dc.rightsNuclear Instruments & Methods in Physics Research Section A Accelerators, Spectrometers, Detectors, and Associated Equipment. Copyright © Elsevier BV.en_HK
dc.titleA fully automated radon exposure chamberen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0168-9002&volume=A350&spage=566&epage=571&date=1994&atitle=A+fully+automated+radon+exposure+chamberen_HK
dc.identifier.emailLeung, JKC: jkcleung@hku.hken_HK
dc.identifier.authorityLeung, JKC=rp00732en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/0168-9002(94)91259-9-
dc.identifier.scopuseid_2-s2.0-0028539887en_HK
dc.identifier.hkuros4146en_HK
dc.identifier.volume350en_HK
dc.identifier.issue3en_HK
dc.identifier.spage566en_HK
dc.identifier.epage571en_HK
dc.identifier.isiWOS:A1994PP21700020-
dc.publisher.placeNetherlandsen_HK
dc.identifier.scopusauthoridLeung, JKC=24080627200en_HK
dc.identifier.scopusauthoridJia, D=7101755080en_HK
dc.identifier.scopusauthoridTso, MyW=7102052118en_HK
dc.identifier.issnl0168-9002-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats