Article: Improvement on thermal diffusivity measurement repeatability of laser flash method
Title | Improvement on thermal diffusivity measurement repeatability of laser flash method |
---|---|
Authors | |
Keywords | Emi Labview Laser Flash Method Metrology Repeatability |
Issue Date | 2008 |
Citation | Jiliang Xuebao/Acta Metrologica Sinica, 2008, v. 29 n. 6, p. 280-282 How to Cite? |
Abstract | Electromagnetic interference (EMI) disturbs significantly thermal diffusivity measurements by laser flash method. This paper presented a progress in suppressing EMI by developing a new amplifier, programming a new software of digital filters, promoting the stability of furnace and applying a high performance data acquisition card. A armco iron sample whose thickness is 2.88mm was measured once again, the repeatability was observed to be improved from the previous 1%-3% into the present less than 8‰. |
Persistent Identifier | http://hdl.handle.net/10722/91289 |
ISSN | 2023 SCImago Journal Rankings: 0.233 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Liu, J-Q | en_HK |
dc.contributor.author | Sun, J-P | en_HK |
dc.contributor.author | Zhang, J-T | en_HK |
dc.contributor.author | Cheng, Y-F | en_HK |
dc.date.accessioned | 2010-09-17T10:16:17Z | - |
dc.date.available | 2010-09-17T10:16:17Z | - |
dc.date.issued | 2008 | en_HK |
dc.identifier.citation | Jiliang Xuebao/Acta Metrologica Sinica, 2008, v. 29 n. 6, p. 280-282 | en_HK |
dc.identifier.issn | 1000-1158 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/91289 | - |
dc.description.abstract | Electromagnetic interference (EMI) disturbs significantly thermal diffusivity measurements by laser flash method. This paper presented a progress in suppressing EMI by developing a new amplifier, programming a new software of digital filters, promoting the stability of furnace and applying a high performance data acquisition card. A armco iron sample whose thickness is 2.88mm was measured once again, the repeatability was observed to be improved from the previous 1%-3% into the present less than 8‰. | en_HK |
dc.language | eng | en_HK |
dc.relation.ispartof | Jiliang Xuebao/Acta Metrologica Sinica | en_HK |
dc.subject | Emi | en_HK |
dc.subject | Labview | en_HK |
dc.subject | Laser Flash Method | en_HK |
dc.subject | Metrology | en_HK |
dc.subject | Repeatability | en_HK |
dc.title | Improvement on thermal diffusivity measurement repeatability of laser flash method | en_HK |
dc.type | Article | en_HK |
dc.identifier.email | Cheng, Y:yuecheng@hku.hk | en_HK |
dc.identifier.authority | Cheng, Y=rp1320 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.scopus | eid_2-s2.0-60149086053 | en_HK |
dc.identifier.volume | 29 | en_HK |
dc.identifier.issue | 6 | en_HK |
dc.identifier.spage | 280 | en_HK |
dc.identifier.epage | 282 | en_HK |
dc.identifier.issnl | 1000-1158 | - |