File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1034/j.1600-0501.1994.050302.x
- Scopus: eid_2-s2.0-0028510066
- PMID: 7827226
- WOS: WOS:A1994PJ19700002
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Membrane permeability is unnecessary for guided generation of new bone. An experimental study in the rabbit.
Title | Membrane permeability is unnecessary for guided generation of new bone. An experimental study in the rabbit. |
---|---|
Authors | |
Keywords | barrier membrane bone generation guided tissue regeneration new bone formation osseointegration |
Issue Date | 1994 |
Publisher | Wiley-Blackwell Publishing, Inc.. The Journal's web site is located at http://www.blackwellpublishing.com/journals/CLR |
Citation | Clinical Oral Implants Research, 1994, v. 5 n. 3, p. 125-130 How to Cite? |
Abstract | The aim of this investigation was to test the hypothesis that membrane permeability is necessary in bone formation using the principle of guided tissue regeneration. On the forehead of 8 rabbits, titanium test cylinders were anchored in the calvaria. These cylinders were either covered by an expanded polytetrafluoroethylene (ePTFE) membrane generating a chamber for bone formation or they were sealed off by cast titanium. The implanted cylinders were covered by resuturing the periosteum and the cutaneous flap. After 8 months of healing, new bone had formed in all cylinders in all animals irrespective of whether the chamber for bone formation was sealed off by cast titanium or the ePTFE membrane. Based on these results, we conclude that permeability of the membrane is not necessary in the guided generation of new bone. |
Persistent Identifier | http://hdl.handle.net/10722/153889 |
ISSN | 2023 Impact Factor: 4.8 2023 SCImago Journal Rankings: 1.865 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Schmid, J | en_US |
dc.contributor.author | Hämmerle, CH | en_US |
dc.contributor.author | Olah, AJ | en_US |
dc.contributor.author | Lang, NP | en_US |
dc.date.accessioned | 2012-08-08T08:22:07Z | - |
dc.date.available | 2012-08-08T08:22:07Z | - |
dc.date.issued | 1994 | en_US |
dc.identifier.citation | Clinical Oral Implants Research, 1994, v. 5 n. 3, p. 125-130 | en_US |
dc.identifier.issn | 0905-7161 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/153889 | - |
dc.description.abstract | The aim of this investigation was to test the hypothesis that membrane permeability is necessary in bone formation using the principle of guided tissue regeneration. On the forehead of 8 rabbits, titanium test cylinders were anchored in the calvaria. These cylinders were either covered by an expanded polytetrafluoroethylene (ePTFE) membrane generating a chamber for bone formation or they were sealed off by cast titanium. The implanted cylinders were covered by resuturing the periosteum and the cutaneous flap. After 8 months of healing, new bone had formed in all cylinders in all animals irrespective of whether the chamber for bone formation was sealed off by cast titanium or the ePTFE membrane. Based on these results, we conclude that permeability of the membrane is not necessary in the guided generation of new bone. | en_US |
dc.language | eng | en_US |
dc.publisher | Wiley-Blackwell Publishing, Inc.. The Journal's web site is located at http://www.blackwellpublishing.com/journals/CLR | en_US |
dc.relation.ispartof | Clinical oral implants research | en_US |
dc.subject | barrier membrane | - |
dc.subject | bone generation | - |
dc.subject | guided tissue regeneration | - |
dc.subject | new bone formation | - |
dc.subject | osseointegration | - |
dc.subject.mesh | Animals | en_US |
dc.subject.mesh | Bone Regeneration - Physiology | en_US |
dc.subject.mesh | Cross-Sectional Studies | en_US |
dc.subject.mesh | Guided Tissue Regeneration | en_US |
dc.subject.mesh | Membranes, Artificial | en_US |
dc.subject.mesh | Osteogenesis - Physiology | en_US |
dc.subject.mesh | Permeability | en_US |
dc.subject.mesh | Prostheses And Implants | en_US |
dc.subject.mesh | Rabbits | en_US |
dc.subject.mesh | Skull | en_US |
dc.subject.mesh | Titanium | en_US |
dc.title | Membrane permeability is unnecessary for guided generation of new bone. An experimental study in the rabbit. | en_US |
dc.type | Article | en_US |
dc.identifier.email | Lang, NP:nplang@hkucc.hku.hk | en_US |
dc.identifier.authority | Lang, NP=rp00031 | en_US |
dc.description.nature | link_to_subscribed_fulltext | en_US |
dc.identifier.doi | 10.1034/j.1600-0501.1994.050302.x | - |
dc.identifier.pmid | 7827226 | - |
dc.identifier.scopus | eid_2-s2.0-0028510066 | en_US |
dc.identifier.volume | 5 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.spage | 125 | en_US |
dc.identifier.epage | 130 | en_US |
dc.identifier.isi | WOS:A1994PJ19700002 | - |
dc.publisher.place | United States | en_US |
dc.identifier.scopusauthorid | Schmid, J=8419181200 | en_US |
dc.identifier.scopusauthorid | Hämmerle, CH=7005331848 | en_US |
dc.identifier.scopusauthorid | Olah, AJ=7006654753 | en_US |
dc.identifier.scopusauthorid | Lang, NP=7201577367 | en_US |
dc.identifier.issnl | 0905-7161 | - |